Ce Approved Wire XLPE Insulation PVC Sheathed Wire, Power Cable

Ce Approved Wire XLPE Insulation PVC Sheathed Wire, Power Cable

Ce Approved Wire XLPE Insulation PVC Sheathed Wire, Power Cable

YJV22/YJV32/YJV

Jiapu

Various

ISO, CCC, CE, RoHS, VDE, SABS

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

Swa or Sta or Awa

IEC, NFC, ASTM, Bis, DIN and So on

Jiapu

Export Wooden Drums

IEC ASTM BS DIN, Any standard

China

8544492100

Product Description

CE approved  wire XLPE Insulation PVC Sheathed Wire, Power Cable

Copper/XLPE Insulated / SWA /Power Cable (0.6/1KV, 6/35KV) specification:

Number Of core: 1core to 5 cores, 3+1 cores, 3+2 cores, 4+1 cores

Voltage: 0.6/1KV, 1/35KV

1) Copper (aluminium) cores / XLPE insulated / PVC(PE) sheathed power cable

2) Copper (aluminium) cores /XLPE insulated /steel tape armored/ PVC ( PE) sheathed power cable

3) Copper (aluminium) cores /XLPE insulated / thin steel wire armored/ PVC ( PE) sheathed power cable

4) Copper (aluminium) cores /XLPE insulated / thick steel wire armored/ PVC ( PE) sheathed power cable

The products can be produced according to our factory specification which is equivalent to the standard IEC, ASTM, DIN. BS. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.

Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Export wooden drums

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
 No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 2.5 0.1 1.2 0.2 1.9 37.9 1.87 2.32
3 X 35 6.9 2.5 0.1 1.3 0.5 2 41.5 2.1 2.73
3 X50 8.2 2.5 0.1 1.3 0.5 2 44.3 2.37 3.22
3 X 70 9.7 2.5 0.1 1.4 0.5 2.1 47.9 2.77 4
3 X 95 11.3 2.5 0.1 1.4 0.5 2.2 51.6 3.21 4.91
3 X 120 12.8 2.5 0.1 1.5 0.5 2.4 55.4 3.69 5.84
3 X 150 14.2 2.5 0.1 1.5 0.5 2.5 58.6 4.15 6.85
3 X 185 15.9 2.5 0.1 1.5 0.5 2.6 62.5 4.73 8.11
3 X 240 18.3 2.6 0.1 1.6 0.5 2.7 68.5 5.62 10.05
3 X 300 20.4 2.8 0.1 1.7 0.5 2.9 74.5 6.55 12.11
3 X 400 23.2 3 0.1 1.9 0.8 3.2 83.6 8.78 15.86
3 X 500 26.4 3.2 0.1 2.1 0.8 3.4 93 10.52 18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 3.4 0.1 1.3 0.5 2 43.4 2.16 2.61
3 X 35 6.9 3.4 0.1 1.3 0.5 2 45.4 2.36 2.99
3 X50 8.2 3.4 0.1 1.4 0.5 2.2 48.8 2.69 3.54
3 X 70 9.7 3.4 0.1 1.5 0.5 2.3 52.4 3.1 4.33
3 X 95 11.3 3.4 0.1 1.5 0.5 2.4 56.1 3.56 5.26
3 X 120 12.8 3.4 0.1 1.5 0.5 2.5 59.5 4.04 6.19
3 X 150 14.2 3.4 0.1 1.5 0.5 2.6 62.7 4.49 7.19
3 X 185 15.9 3.4 0.1 1.6 0.5 2.6 66.6 5.12 8.49
3 X 240 18.3 3.4 0.1 1.7 0.5 2.8 72.4 5.99 10.42
3 X 300 20.4 3.4 0.1 1.8 0.5 3 77.5 6.86 12.42
3 X 400 23.2 3.4 0.1 1.9 0.8 3.2 85.4 8.97 16.05
3 X 500 26.4 3.4 0.1 2 0.8 3.4 93.7 10.65 19.5
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 4.5 0.1 1.4 0.5 2.1 48.6 2.53 2.98
3 X 35 6.9 4.5 0.1 1.4 0.5 2.2 50.7 2.76 3.39
3 X50 8.2 4.5 0.1 1.5 0.5 2.3 53.9 3.1 3.95
3 X 70 9.7 4.5 0.1 1.5 0.5 2.4 57.4 3.51 4.74
3 X 95 11.3 4.5 0.1 1.5 0.5 2.6 61.2 4.05 5.75
3 X 120 12.8 4.5 0.1 1.6 0.5 2.6 64.7 4.56 6.72
3 X 150 14.2 4.5 0.1 1.6 0.5 2.7 67.9 5.04 7.74
3 X 185 15.9 4.5 0.1 1.7 0.5 2.8 71.9 5.66 9.04
3 X 240 18.3 4.5 0.1 1.8 0.5 3 77.7 6.56 11
3 X 300 20.4 4.5 0.1 1.9 0.8 3.2 84.1 8.39 13.96
3 X 400 23.2 4.5 0.1 2 0.8 3.3 90.5 9.71 16.79
3 X 500 26.4 4.5 0.1 2.1 0.8 3.5 98.8 11.45 20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35 6.9 5.5 0.1 1.5 0.5 2.4 55.6 3.14 3.77
3 X50 8.2 5.5 0.1 1.5 0.5 2.5 58.6 3.49 4.34
3 X 70 9.7 5.5 0.1 1.5 0.5 2.6 62.1 3.93 5.16
3 X 95 11.3 5.5 0.1 1.6 0.5 2.6 65.7 4.46 6.16
3 X 120 12.8 5.5 0.1 1.7 0.5 2.7 69.4 5 7.15
3 X 150 14.2 5.5 0.1 1.7 0.5 2.8 72.6 5.49 8.19
3 X 185 15.9 5.5 0.1 1.8 0.5 3 76.9 6.16 9.53
3 X 240 18.3 5.5 0.1 1.9 0.8 3.2 83.9 7.87 12.31
3 X 300 20.4 5.5 0.1 2 0.8 3.2 88.6 8.96 14.52
3 X 400 23.2 5.5 0.1 2.1 0.8 3.5 95.4 10.35 17.43
3 X 500 26.4 5.5 0.1 2.2 0.8 3.7 103.7 12.45 20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35                  
3 X50 8.2 8 0.1 1.7 0.5 2.8 70.4 4.56 5.41
3 X 70 9.7 8 0.1 1.7 0.5 2.9 73.9 5.04 6.26
3 X 95 11.3 8 0.1 1.8 0.5 3 77.7 5.62 7.32
3 X 120 12.8 8 0.1 1.9 0.8 3.2 82.8 6.99 9.15
3 X 150 14.2 8 0.1 1.9 0.8 3.2 85.8 7.56 10.26
3 X 185 15.9 8 0.1 2 0.8 3.3 89.9 8.3 11.67
3 X 240 18.3 8 0.1 2.1 0.8 3.5 95.7 9.36 13.79
3 X 300 20.4 8 0.1 2.2 0.8 3.6 100.6 10.51 16.07
3 X 400 23.2 8 0.1 2.3 0.8 3.8 107.2 11.99 19.07
3 X 500 26.4 8 0.1 2.4 0.8 4 120.1 14.15 23.85
 

Workshop

Shipment

QA&QC

CUSTOMER VISIT

FAQ

1. How many years has Henan Jiapu Cable Group been in production?

Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

 

2. What kinds of products does Jiapu Cable manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

 

3. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

 

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

 

5. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

 

6. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

 

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

 

8. Do you supply the customers with installation service in foreign country ?We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.