Cable torsade 3×35+54.6mm2 Alu-1kV
 
conductors
 
The LV cable used for carrying out the work will be of insulated type, pre assembled rated voltage beams 0,6 / 1 kV.
The beam will consist of three phase conductors, a neutral conductor and two public ligHVing conductors (PE). The sections are specified in the following table:2x16mm2
 
Cables insulated conductors
 
These technical clauses specify the following cables insulated conductors:
– LV conductor cables for lines of LV networks
– LV cable conductors for LV circuit breakers transformers links,
– Cable connection LV drivers of public ligHVing fixtures,
LV networks will consist of insulated cables assembled in bundles composed as follows:
– 2 core phase conductors of an aluminum section 16 mm²
– without carrier neutral conductor core Almelec a section of 54.6 mm²
– without public ligHVing conductors aluminum core of a section of 16 mm²
 
Materials
 
Insulated cable assembled LV network to beam
The cable will meet the French standard NF C 33-209. The souls of the phase conductors and public ligHVing will consist of hardened aluminum son pure hard 3/4 99.5 M, Type 1370 (A5 / L) to the standard NF C 3 1-122, while core of the neutral conductor is formed of son alloy magnesium aluminum silicon, heat-treated, containing approximately 0.5% magnesium and 0.5% silicon.
Each driver of the beam will be insulated with cross-linked polyethylene extruded jacket black meets the dimensional and mechanical characteristics specified in the NFC 33-209 standards.

FICHE TECHNIQUE
Câble torsadé 3×35+54.6mm2 Alu-1kV
No. DESCRIPTION UNIT  DATA 
1 Norme    IEC 60502-1,NFC 33-209
2 Tension nominale Volt 600/1000
3 Section  mm² 3×35+54.6
4 Phase core    
4.1 Conducteur    
Matière Aluminum
Phase Section No.x mm2 3×35
Nombre de brins du conducteur  No.s  7
Diamètre du conducteur approximatif  mm 6.6-7.5
Résistance maximale du conducteur à 20°C Ω/km 0.868
4.2 Phase Isolation    
Matière PR(XLPE)
Epaisseur nominale de l’isolant mm 1.60
5 Neutre core    
5.1 Conducteur    
Matière Aluminum Alloy
Neutre Section No.x mm2 1×54.6
Nombre de brins du conducteur No.s 7
Diamètre du conducteur approximatif  mm 9.45
5.2 Neutre Isolation    
Matière PR(XLPE)
Epaisseur nominale de l’isolant mm 1.60
6 Diamètre total du câble approximatif  mm 26.2
7 Poids approximatif du câble kg/km 620