Bare Overhead Conductor AAAC 50mm2 with DIN 48201 Standard

Bare Overhead Conductor AAAC 50mm2 with DIN 48201 Standard

Bare Overhead Conductor AAAC 50mm2 with DIN 48201 Standard

AAAC 50MM2

Jinyuan

AAAC 50mm2

ISO, CCC, CE, RoHS, UL, VDE

Round Wire

None

Bare

DC Cable

High Voltage Cable

Overhead

Aluminum Alloy

Silver

IEC,ASTM,BS,DIN,GB/T

Transmission Line,Overhead

Manufacturer

1 Year

15 Days

Free Sample Is Avaliable

HuaTong

Wooden Drum; Wooden Steel Drum; All Steel Drum

AAAC 50MM2

China

Product Description

1. Brief Introduction:
AAAC (All Aluminum Alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
 
Having lower breaking loads than the latter, their use becomes particularly favourable when ice and win loadings are low. 
We can supply this conductor according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied. 
 
2.  Applications:
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
 
3. Standards&Specifications:
All Aluminium Alloy Conductor-AAAC (DIN 48201 Standard Sizes)
 

Nominal Area Conductor Construction Calculated Area Overall Diameter Weight DC Resistance at 20
mm2 No./mm mm2 mm kg/km Ω/km
16 7/1.70 15.9 5.1 43.5 2.091
25 7/2.10 24.2 6.3 66.4 1.370
35 7/2.50 34.4 7.5 94.1 0.9669
50 7/3.00 49.5 9.0 135 0.6714
50 19/1.80 48.3 9.0 133 0.6905
70 19/2.10 65.8 10.5 181 0.5073
95 19/2.50 93.3 12.5 257 0.358
120 19/2.80 117 14 322 0.2854
150 37/2.25 147 15.7 406 0.2274
185 37/2.50 182 17.5 501 0.1842
240 61/2.25 243 20.2 671 0.1383
300 61/2.50 299 22.5 828 0.1120
400 61/2.89 400 26.0 1,106 0.0838
500 61/3.23 500 29.1 1382 0.06709
625 91/2.96 626 32.6 1,735 0.05367
800 91/3.35 802 36.9 2,222 0.0419
1000 91/3.74 1,000 41.1 2,770 0.03362

 

                                           ALUMINIUM ALLOY CONDUCTOR                  ASTM B399
Code Name Area Size&Stranding of ACSR with equal diameter No. and diameter  Overall diameter Weight Nominal breaking load MAX .DC resistance at 20ºC
Nominal Actual AWG or MCM Al/St
  MCM mm2     mm mm kg/km kN ohm/km
AKRON 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92 0.3966
ALTON 48.69 24.71 4 6/1 7/2.12 6.35 68 7.84 0.3811
AMES 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45 0.3671
AZUSA 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97 0.3524
ANAHEIM 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93 0.3448
AMHERST 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18 0.3375
ALLIANCE 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05 0.3306
BUTTE 312.8 158.6 266.8 26/7 19/3.26 16.3 437 48.76 0.3196
CANTON 394.5 199.9 366.4 26/7 19/3.66 18.3 551 58.91 0.3124
CAIRO 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48 0.3071
DARIEN 559.5 283.5 477 26/7 19/4.36 21.79 781 83.52 0.3014
ELGIN 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42 0.2966
FLINT 740.8 375.3 636 26/7 37/3.59 25.16 1035 108.21 0.2917
GREELY 927.2 469.8 795 26/7 37/4.02 28.14 1295 135.47 0.2846

 
 

Area Stranding and wire diameter Approx. overall diameter Weight Nominal Breaking Load MAX .DC resistance at 20ºC
Nominal Actual
AWGorMCM (mm2) (mm) (mm) (kg/km) (kN) (ohm/km)
6 13.30 7/1.554 4.67 37 4.22 2.5199
4 21.15 1/1.961 5.89 58 6.71 1.5824
2 33.63 7/2.474 7.42 93 10.68 0.9942
1/0 53.48 7/3.119 9.36 148 16.97 0.6256
2/0 67.42 7/3.503 10.51 186 20.52 0.4959
3/0 85.03 7/3.932 11.8 234 25.86 0.3936
4/0 107.23 7/4.417 13.26 296 32.63 0.3119
250 126.66 19/2.913 14.57 349 38.93 0.2642
300 152.1 19/3.193 15.97 419 46.77 0.2199
350 177.35 19/3.447 17.24 489 52.25 0.1887
400 202.71 19/3.686 18.43 559 59.74 0.1650
450 228 19/3.909 19.55 629 67.19 0.1467
500 253.35 19/4.120 20.60 698 74.64 0.1321
550 278.60 37/3.096 21.67 768 83.80 0.1202
600 303.80 37/3.233 22.63 838 91.38 0.1102
650 329.25 37/3.366 23.56 908 97.94 0.1016
700 354.55 37/3.493 24.45 978 102.20 0.0944
750 380.20 37/3.617 25.32 1049 109.60 0.0880
800 405.15 37/3.734 26.14 1117 116.80 0.0826
900 456.16 37/3.962 27.73 1258 131.50 0.0733
1000 506.71 37/4.176 29.23 1399 146.10 0.0660
1100 557 61/3.41 30.69 1537 162.16 0.0589
1200 608 61/3.56 32.04 1677 176.75 0.0541
1300 659 61/3.71 33.39 1816 191.95 0.0498
1400 709 61/3.85 34.65 1955 206.72 0.0463
1500 760 61/3.98 35.82 2095 220.90 0.0441
1600 811 61/4.12 37.08 2236 235.57 0.0405
1700 861 61/4.24 38.16 2374 250.72 0.0382
1800 912 61/4.36 39.28 2514 265.11 0.03693
1900 963 91/3.67 40.37 2655 277.10 0.03411
2000 1013 91/3.76 41.4 2793 292.41 0.03243

 
 

                                    ALUMINIUM ALLOY CONDUCTOR             BSEN50183
Code Name Calculated Area No. Of Wires Diameter Weight Rated Strength MAX .DC resistance at 20ºC
Wire Cond.
  mm2   mm mm kg/km Kn ohm/km
Box 18.8 7 1.85 5.55 51.4 5.55 1.748
Acacia 23.8 7 2.08 6.24 64.9 7.02 1.3828
Almond 30.1 7 2.34 7.02 82.2 8.88 1.0926
Cedar 35.5 7 2.54 7.62 96.8 10.46 0.9273
Deodar 42.2 7 2.77 8.31 115.2 12.44 0.7797
Fir 47.8 7 2.95 8.85 130.6 14.11 0.6875
Hazel 59.9 7 3.3 9.9 163.4 17.66 0.5494
Pine 71.6 7 3.61 10.8 195.6 21.14 0.4591
Holly 84.1 7 3.91 11.7 229.5 24.79 0.3913
Willow 89.7 7 4.04 12.1 245 26.47 0.3665
Oak 118.9 7 4.65 14 324.5 35.07 0.2767
Mulberry 150.9 19 3.18 15.9 414.3 44.52 0.2192
Ash 180.7 19 3.48 17.4 496.1 53.31 0.183
Elm 211 19 3.76 18.8 579.2 62.24 0.1568
Poplar 239.4 37 2.87 20.1 659.4 70.61 0.1387
Sycamore 303.2 37 3.23 22.6 835.2 89.4 0.1095
Upas 362.1 37 3.53 24.7 997.5 106.82 0.0917
Yew 479 37 4.06 28.4 1319.6 141.31 0.0693
Totara 498.1 37 4.14 29 1372.1 146.93 0.0666
Rubus 586.9 61 3.5 31.5 1622 173.13 0.0567
Sorbus 659.4 61 3.71 33.4 1822.5 194.53 0.0505
Araucaria 821.1 61 4.14 37.3 2269.4 242.24 0.0406
Redwood 996.2 61 4.56 41 2753.2 293.88 0.0334

 

ALUMINIUM ALLOY CONDUCTOR                BS 3242
Code Name Calculated Area No. Of Wires Diameter Weight Rated Strength MAX .DC resistance at 20ºC
Wire Cond.
  mm2   mm mm kg/km Kn ohm/km
Box 15 7/1.85 18.82 5.55 51 537 1.7495
Acacia 20 7/2.08 23.79 6.24 65 680 1.384
Almond 25 7/2.34 30.1 7.02 82 861 1.0934
Cedar 30 7/2.54 35.47 7.62 97 1014 0.9281
35 7/2.77 42.18 8.31 115 1205 0.7804
Fir 40 7/2.95 47.87 8.85 131 1367 0.688
Hazel 50 7/3.30 59.87 9.9 164 1711 0.5498
Pine 60 7/3.61 71.65 10.83 196 2048 0.4594
70 7/3.91 84.05 11.73 230 2402 0.3917
Willow 75 7/4.04 89.73 12.12 245 2565 0.3669
80 7/4.19 96.52 12.57 264 2758 0.3441
90 7/4.44 108 13.32 298 3112 0.3023
Oak 100 7/4.65 118.9 13.95 325 3398 0.2769
100 19/2.82 118.7 14.1 326 3393 0.2787
Mulbery 125 19/3.18 150.9 15.9 415 4312 0.2192
Ash 150 19/3.48 180.7 17.4 497 5164 0.1831
Elm 175 19/3.76 211 18.8 580 6030 0.1568
Poplar 200 37/2.87 239.4 20.09 659 8841 0.1385
225 37/3.05 270.3 21.35 744 7724 0.1227
Sycamore 250 37/3.22 303.2 22.54 835 8664 0.1093
Upas 300 37/3.53 362.1 24.71 997 10350 0.09156
Walnut 350 37/3.81 421.8 26.67 1162 12053 0.0786
Yew 400 37/4.06 479 28.42 1319 13685 0.06921
Totara 425 37/4.14 498.1 28.98 1372 14233 0.06656
Rubus 500 61/3.50 586.9 31.5 1620 16771 0.05662
Araucaria 700 61/4.14 821.1 37.26 2266 23450 0.04047

4.FAQ
(1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please
call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight
charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7
days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is
delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months
before the date you would like to get the products at your country.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.

Similar Or Related