Bare Conductors AAAC Conductors

Bare Conductors AAAC Conductors

Bare Conductors AAAC Conductors

AAAC

Construction, Overhead, Industrial, Power Station

High Voltage Cable

AC Cable

Bare

Round Wire

Steel

ISO, CCC

SABS

SABS

ASTM, IEC, DIN, CSA, BS…

JP

Export Wooden Drum or Wooden Steel Drum

China

7614900000

Product Description

LAS ESPECIFICACIONES TECNICAS DEL CONDUCTOR AAAC 120MM2

Product Description

All Aluminum Alloy Conductor (AAAC) Cables
Application of AAAC 120mm2
AAAC is mainly used as bare overhead transmission cable and as primary and secondary
distribution cable. It is also suitable for laying across basins, rivers and valleys where
special geographical teatures exist.
standard of AAAC 120mm2
Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201
-6 standards

Construction of AAAC 120mm2
AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically
stranded.
This section deals with heat-treatable magnesium silicon type aluminium alloys to the
applicable International Standard, the electrical and mechanical properties of which all
fall within the values suggested by relevant standard. Conductors to all other recognized
specifications can also be supplied. The alloys referred to have higher strength but lower
conductivity than pure aluminium. Being lighter, alloy conductors can sometimes be used
to advantage in place of the more conventional ACSR; Having lower breaking loads than
the later, their use becomes particularly favourable when ice and wind loadings are low.
.
ELECTRICAL PROPERTIES of AAAC120mm2
linear Expansivity 23 x10-6 (°C)

Service conditions
Ambient Temperature -5°C – 50°C
Wind Pressure 80 – 130kg/m2
Seismic Acceleration 0.12 – 0.05g
isokeraunic level 10 – 18
relative Humidity 5 – 100%

Construction Parameters of AAAC 120mm2
DIN 48201 part 6

Nominal Area stranding Overall Diameter weight rated strength Electrical Resistance Current Rating*
Nominal Teorical
mm2 mm2 No.×mm mm Kg/Km KN Ω/Km A
16 15.89 7/1.70 5.1 43 4.44 2.0742 78
25 24.25 7/2.10 6.3 66 6.77 1.3593 102
35 34.36 7/2.50 7.5 94 9.6 0.9591 126
50 49.48 7/3.00 9 135 13.82 0.666 158
50 48.35 19/1.80 9 133 13.5 0.6849 156
70 65.81 19/2.10 10.5 181 18.38 0.5032 189
95 93.27 19/2.50 12.5 256 26.05 0.3551 234
120 116.99 19/2.80 14 322 32.68 0.2831 269
150 147.11 37/2.25 15.8 406 41.09 0.2256 309
185 181.62 37/2.50 17.5 500 50.73 0.1828 352
240 242.54 61/2.25 20.3 670 67.74 0.1371 420
300 299.43 61/2.50 22.5 827 83.63 0.111 477
400 400.14 61/2.89 26 1104 111.76 0.0831 568
500 499.83 61/3.23 29.1 1379 139.6 0.0665 649
625* 626.2 91/2.96 32.6 1732 174.9 0.0531 742
800* 802.09 91/3.35 36.9 2218 224.02 0.0415 857
1000* 999.71 91/3.74 41.1 2767 279.22 0.0333 971

(*)Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

Bonnie Wang (Ms)
Marketing Manager
Henan Jiapu Cable Co.,Ltd
Add: No 18 Building, No 283 Xisanhuan Road, Zhengzhou, China
Direct Tel: +86-371-55367868 Ext.611
Phone number:0086-18339931106

jiapucable

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.