Bare AAAC Conductor Cairo 465.4mcm 19/3.98mm ASTM B399
Product Description
Application:
Overhead transmission and primary and secondary distribution .
The alloys referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional acsr; Having lower breaking loads than the latter, their use becomes particularly favourable When ice and win loadings are low.
Construction:
AAAC is a high-strength aluminum alloy, concentric-lay-stranded conductor.
It is similar in construction and appearance to the AAC all-aluminum conductor. The AAAC conductor is manufactured in accordance with the requirements of the latest issue of ASTM B399. The AAAC conductor is manufactured from a heat-treated, magnesium-silicide high-strength 6201-T81 aluminum alloy. The aluminum strands consist of a concentric stranded cable of 7, 19, 37 or more wires. The sizes and strands listed are common examples used in overhead lines. Metric (mm) sizes are also available.
1). All aluminum alloy stranded conductor cable are for power transmission and distribution.
2). Standard: GB1179, iec61089, bs3242, DIN48201, ASTM b399
3). We accept OEM orders with other equivalent standards.
4).packing: Can be supplied in any length required .
we also supply AAC(all aluminum conductor), ACSR(aluminium conductor steel reinforced).
Other special charastics: design and manufacture according to customers’s request
Please contact us freely ; may be I will give you a big surprise !
Code word | Conductor size | Stranding | Section area | Diameter of conductor | Linear mass | Rated strength | D.C. resistance at 20ºC |
AWG (MCM) | No./mm | mm2 | mm | Kg/km | kgf | Ω/km | |
Akron | 7/1.68 | 15.51 | 5.04 | 42.7 | 502 | 2.15980 | |
4 | 7/1.96 | 21.14 | 5.89 | 57.89 | 685 | 1.35570 | |
Alton | 48.69(4) | 7/2.12 | 24.67 | 6.35 | 67.56 | 799 | 1.58600 |
2 | 7/2.47 | 33.65 | 7.42 | 92.14 | 1091 | 0.99870 | |
Ames | 77.47(2) | 7/2.67 | 39.26 | 8.02 | 107.50 | 1275 | 0.85470 |
1/0 | 7/3.12 | 53.49 | 9.35 | 146.50 | 1733 | 0.62590 | |
Azusa | 123.3(1/0) | 7/3. 37 | 62.46 | 10.11 | 171.00 | 2019 | 0.53650 |
2/0 | 7/3.50 | 67.45 | 10.52 | 184.70 | 2090 | 0.49740 | |
Anaheim | 155.4(2/0) | 7/3.78 | 78.75 | 11.35 | 215.16 | 2447 | 0.42640 |
3/0 | 7/3.93 | 85.00 | 11.79 | 232.70 | 2641 | 0.39450 | |
Amherst | 195.7 (3/0) | 7/4.25 | 99.20 | 12.75 | 271.50 | 3079 | 0.33730 |
4/0 | 7/4.42 | 107.20 | 13.26 | 293.70 | 3334 | 0.31190 | |
Alliance | 246.9 (4/0) | 7/4.77 | 125.10 | 14.30 | 342.60 | 3885 | 0.26780 |
250.0 | 19/2.91 | 126.70 | 14.58 | 346.90 | 3977 | 0.26510 | |
300.0 | 19/3.19 | 152.10 | 15.89 | 418.60 | 4772 | 0.22060 | |
Butte | 312.8 | 19/3.26 | 158.50 | 16.31 | 434.00 | 4976 | 0.21120 |
350.0 | 19/3.45 | 177.30 | 17.25 | 485.50 | 5333 | 0.18860 | |
Canton | 394.5 | 19/3.66 | 199.00 | 18.31 | 547.40 | 6016 | 0.16760 |
19/3.69 | 202.70 | 18.44 | 555.10 | 6098 | 0.16490 | ||
450.0 | 19/3.91 | 228.00 | 19.56 | 624.40 | 6862 | 0.14680 | |
Cairo | 456.4 | 19/3.98 | 235.80 | 19.89 | 645.70 | 7097 | 0.14310 |
500.0 | 19/4.12 | 253.40 | 20.60 | 693.60 | 7617 | 0.13220 | |
550.0 | 37/3.10 | 278.70 | 21.67 | 762.90 | 8555 | 0.12000 | |
Darien | 559.5 | 19/4.36 | 283.50 | 21.79 | 776.30 | 8525 | 0.11810 |
660.0 | 37/3.23 | 304.00 | 22.63 | 832.00 | 9330 | 0.11050 | |
650.0 | 37/3.37 | 329.40 | 23.57 | 909.80 | 10105 | 0.10150 | |
Elgin | 652.4 | 19/4.71 | 330.60 | 23.55 | 970.60 | 9942 | 0.10120 |
700.0 | 37/3.49 | 354.50 | 24.46 | 910.60 | 10401 | 0.09464 | |
Flint | 740.8 | 37/3.59 | 375.40 | 25.15 | 1028.00 | 11013 | 0.08944 |
750.0 | 37/3.62 | 380.20 | 25.32 | 1041.00 | 11216 | 0.08796 | |
800.0 | 37/3.73 | 405.40 | 26.14 | 1109.00 | 11930 | 0.08285 | |
900.0 | 37/3.96 | 456.30 | 27.74 | 1249.00 | 13460 | 0.07351 | |
Greeley | 927.2 | 37/4.02 | 469.80 | 28.14 | 1287.00 | 13868 | 0.07133 |
1000.0 | 37/4.18 | 506.70 | 29.24 | 1388.00 | 14887 | 0.06597 | |
1077.4 | 61/3.38 | 483.40 | 30.42 | 1496.00 | 15907 | 0.06120 | |
1165.1 | 61/3.51 | 523.70 | 31.59 | 1617.00 | 17233 | 0.05675 | |
1250.0 | 61/3.63 | 633.30 | 32.67 | 1733.00 | 18354 | 0.05306 | |
1259.6 | 61/3.65 | 564.00 | 32.85 | 1748.00 | 18558 | 0.05248 | |
1348.8 | 61/3.78 | 604.20 | 34.02 | 1872.00 | 19884 | 0.04893 | |
1439.2 | 61/3.90 | 644.50 | 35.10 | 1997.00 | 21209 | 0.04597 | |
1500.0 | 61/3.98 | 760.00 | 35.82 | 2081.00 | 22127 | 0.04414 | |
1750.0 | 61/4.30 | 886.70 | 38.70 | 2429.00 | 25798 | 0.03781 |
Contact us
Similar Or Related
-
AAC 95mm2 19/2.52 Conductor TIS 85-2548 for Transmission and distribution line
-
CU/XLPE/CTS/PVC 6.35/11kV Single Core Aluminum Power Cable IEC 60502-2
-
Al/XLPE/CTS/PVC 19/33kV 36kV Single Core Aluminum Power Cable IEC 60502-2
-
Yjlv XLPE Insulated and PVC Sheathed Power Cable Alu/XLPE/PVC
-
(AL/XLPE//SWA/PVC) Aluminum Conductor XLPE Insulated PVC Sheathed Yjlv22 Power Cable