Bare AAAC Conductor 6201 -120sqmm 19/2.8mm

Bare AAAC Conductor 6201 -120sqmm 19/2.8mm

Bare AAAC Conductor 6201 -120sqmm 19/2.8mm

AAAC

Bare

Stranded

Overhead

Aluminum Alloy Conductor

None

Without

Round Wire

Overhead

ISO9001, CCC, VDE

Yifang

All Aluminium Alloy Conductor

YIFANG

Wooden Drum, Steel Drum, Wooden&Steel Drum

14awg, 12awg, 8awg, 4awg, 2/0awg, 4/0awg

Zhengzhou, Henan, China

8544492100

Product Description

Aaac (all aluminum alloy conductor)
Application:
Overhead transmission and primary and secondary distribution .
The alloys referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional acsr; Having lower breaking loads than the latter, their use becomes particularly favourable When ice and win loadings are low.
Construction:
AAAC is a high-strength aluminum alloy, concentric-lay-stranded conductor.
It is similar in construction and appearance to the AAC all-aluminum conductor. The AAAC conductor is manufactured in accordance with the requirements of the latest issue of ASTM B399. The AAAC conductor is manufactured from a heat-treated, magnesium-silicide high-strength 6201-T81 aluminum alloy. The aluminum strands consist of a concentric stranded cable of 7, 19, 37 or more wires. The sizes and strands listed are common examples used in overhead lines. Metric (mm) sizes are also available.

1). All aluminum alloy stranded conductor cable are for power transmission and distribution.
2). Standard: GB1179, iec61089, bs3242, DIN48201, ASTM b399
3). We accept OEM orders with other equivalent standards.
4).packing: Can be supplied in any length required .

we also supply AAC(all aluminum conductor), ACSR(aluminium conductor steel reinforced).

Other special charastics: design and manufacture according to customers’s request
Please contact us freely ; may be I will give you a big surprise !

AAAC-Technical characteristics / DIN 48201
               
Conductor size mm2 Alloy area mm2 Number of wires Diameter of wire mm Overall diameter of conductor mm Linear mass kg/km Rated tensile strength daN Maximum resistance D.C. at 20ºC  Ω/km
16 15.89 7 1.70 5.10 43 444 2.0910
25 24.25 7 2.10 6.30 66 677 1.3703
35 34.36 7 2.50 7.50 94 960 0.9669
50 49.48 7 3.00 9.00 135 1382 0.6714
50 48.35 19 1.80 9.00 133 1350 0.6905
70 65.81 19 2.10 10.50 181 1838 0.5073
95 93.27 19 2.50 12.50 256 2605 0.3579
120 116.99 19 2.80 14.00 322 3268 0.2854
150 147.11 37 2.25 15.80 406 4109 0.2274
185 181.62 37 2.50 17.50 500 5073 0.1842
240 242.54 61 2.25 20.30 670 6774 0.1383
300 299.43 61 2.50 22.50 827 8363 0.1120
400 400.14 61 2.89 26.00 1104 11176 0.0838
500 499.63 61 3.23 29.10 1379 13960 0.0671
625 626.2 91 2.96 32.60 1732 17490 0.0540
800 802.09 91 3.35 36.90 2218 22402 0.0418
1000 999.71 91 3.74 41.10 2767 27922 0.0335

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.