Aluminum Conductor XLPE Power Cable 0.6/1kv Low Voltage

Aluminum Conductor XLPE Power Cable 0.6/1kv Low Voltage

Aluminum Conductor XLPE Power Cable 0.6/1kv Low Voltage

0.6/1KV Aluminum conductor/XLPE insualtion

Construction, Underground, Power Station

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Sector or Circular

Aluminum or Copper

ISO, CCC, CE

YJLV22

Yifang

1,2,3,4,5,3+1,3+2,4+1

Yifang

Wooden Drums/Reels or as your request

BS DIN VDE, IEC, ASTM

Henan, China

8544492100

Product Description

The electrical cable is mainly have 2 kinds listing as followings:

1. The PVC insulated power electric cable

The conductor can be copper or aluminium; Be strands or solid

The electrical cable can be very solid or flexible

The insualtion is PVC

The Jacket/Sheath is PVC

Armored or without armored

Class 2 stranded conductors for single-core and multi-core cables
1 2 3 4 5 6 7 8 9 10
Nominal crosssectional area Minimum number of wires in the conductor Maximum resistance of conductor at 20ºC
Circular Circular compacted Shaped Annealed copper conductor Aluminium or aluminium alloy conductor
Cu Al Cu Al Cu Al Plain wires Metal-coated wires
mm2 Ω/KM Ω/KM Ω/KM
0.5 7 36 36.7
0.75 7 24.5 24.8
1 7 18.1 18.2
1.5 7 6 12.1 12.2
2.5 7 6 7.41 7.58
4 7 6 4.61 4.7
6 7 6 3.08 3.11
10 7 7 6 6 1.83 1.84 3.08
16 7 7 6 6 1.15 1.16 1.91
25 7 7 6 6 6 6 0.727 0.734 1.2
35 7 7 6 6 6 6 0.524 0.529 0.868
50 19 19 6 6 6 6 0.387 0.391 0.641
70 19 19 12 12 12 12 0.268 0.27 0.443
95 19 19 15 15 15 15 0.193 0.195 0.32
120 37 37 18 15 18 15 0.153 0.154 0.253
150 37 37 18 15 18 15 0.124 0.126 0.206
185 37 37 30 30 30 30 0.0991 0.1 0.164
240 37 37 34 30 34 30 0.0754 0.0762 0.125
300 61 61 34 30 34 30 0.0601 0.0607 0.1
400 61 61 53 53 53 53 0.047 0.0475 0.0778
500 61 61 53 53 53 53 0.0368 0.0369 0.0605
630 91 91 53 53 53 53 0.0283 0.0286 0.0469
800 91 91 53 53 0.0221 0.0224 0.0367
1000 91 91 53 53 0.0176 0.0177 0.0291

Armoured material: Can be steel tape or steel wire or others as your request!

The recommended nominal cross section is from 1.5 sq mm to 400 sqmm

The core number can be single or multi

The Voltage is 0.6/1kV

The long-time working temperature of cable should not be higher than 70 celsius

When core is in short-circuit(max 5s) the temperature should not be exceed 160 celsius

While installation the ambient temperature should not be lower than 0 celsius

2. The XLPE insulated power electric cable

The conductor can be copper or aluminium; Be strands or solid

The electrical cable can be very solid or flexible

The insualtion is PVC

The Jacket/Sheath is PVC

Armored or without armored

Armoured material: Can be steel tape or steel wire or others as your request!

The recommended nominal cross section is from 1.5 sq mm to 400 sqmm

The core number can be single or multi

The Voltage is 0.6/1, 3.6/6, 6/6, 6/10, 8.7/10, 8.7/15, 21/35, 26/35 kv

The long-time working temperature of cable should not be higher than 90 celsius

When core is in short-circuit(max 5s) the temperature should not be exceed 250 celsius

While installation the ambient temperature should not be lower than 0 celsius

The OEM and customized productes will also be welcomed! !

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.