Aluminum Conductor XLPE Insulated PVC Sheath Power Cables

Aluminum Conductor XLPE Insulated PVC Sheath Power Cables

Aluminum Conductor XLPE Insulated PVC Sheath Power Cables

yjlv

Insulated

Stranded

Underground

Aluminum

PVC

CE

Product Description

Application:
The PVC insulated power cable are suitable for fixed laying in power transmission and distribution lines with A. C. 50Hz and voltage rating of up to or including 6KV.
Performance:

1. The long-term permissible operation temperature of the conductor shall not be higher than 70 degree
2. Conductor maximum short circuit((less then 5 second) temperature shall not be higher than 160 degree
3. The cable is not limited by drop in level when being laid, and the environment temperature shall not be lower than 0 degree
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance
5. Light weight, perfect bending properties, installed and maintained easily and conveniently
6. Rated voltage: 0.6/1kV, 3.6/6kV
7. Conductors: Copper or Aluminum
8. Number of cores: One, two, three, four, five
We can produced it according to IEC60502 and IEC60331, and the product can be produced against the standard of BS, DIN, or other standard according to customers’ requirement.

VV
PVC insulated PVC sheathed power cable
Can be laid at indoor, tunnel and tube. Cable cannot under take mechanism outside force.

VLV
VY
PVC insulated and PE sheathed power cable
Can be laid at indoor, tunnel tube and serious polluted places. Cablecannot undertake mechanism outside force.

VLY
VV22
PVC insulated steel belt armored and PVC sheathed power cable
Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force.
VLV22
VV23
PVC insulated steel belt armored and PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force.

VLV23
VV32
PVC insulated steel belt armored and PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force.

VLV32
VV33
PVC insulated steel belt armored and PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force.

VLV33
VV42
PVC insulated steel belt armored and PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force.

VLV42
VV43
PVC insulated steel belt armored and PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.