Aluminum Conductor XLPE Insulated 35mm ABC Cable (3*35+54.6+1*16, NFC standard)

Aluminum Conductor XLPE Insulated 35mm ABC Cable (3*35+54.6+1*16, NFC standard)

Aluminum Conductor XLPE Insulated 35mm ABC Cable (3*35+54.6+1*16, NFC standard)

3*35+54.6+1*16sqmm

3*35+54.6+(1*16)Sqmm

3

90 Centigrade

XLPE

Overhead Power Transmission

Africa,Asia,South America,Southeast Asia and So on

Yifang Cable

Wooden Drum or Wooden-Steel Drum

CE SABS RoHS SGS UL CCC

Zhengzhou, China

8544492100

Product Description


Specifications
1.NFC 33209 abc cable
2.XLPE/hdpe insulated
3.aerial bundled cable
4.inner shielding layer material
5.weather-proof insulation
Overhead NFC 33209 abc cable size 3*35+54.6+16mm 3*95+54,6mm

It consists of copper or aluminum conductor; inner shielding layer, weather-proof insulation material and outer shielding layer. It not only has power transmitting character of power cable, but also has a strong mechanical character of aerial cable, as well. In comparasion with bare cable, it boasts many advantages, such as, small span in laying the initiative to choose to use.

1. Executive standard:
GB12527-90 1KV Aerial insulation cable (According to IEC502, IEC227 Standard)
GB14049-93 10KV Aerial insulation cable
2. Working conditions of aerial insulation power cable:
1) Rated voltage: 1KV, 10KV
2) The highest working temperature of the cable conductor:
XLPE insulation cable: 90°C
HDPE insulation cable: 75°C
3) During having a short circuit (lasting less than 5 seconds), the maximum temperature:
XLPE insulation cable: 250°C
HDPE insulation cable: 150°C
4) During laying the cable, the ambient temperature must be above -20°C.
5) Bending radius allowance of the cable:
A) 1 KV aerial insulation power cable;
It should be no less than 4D for the cable with outer diameter less than 25mm;
It should be no less than 4D for the cable with outer diameter of than 25mm;
B) 10KV aerial insulation power cable:
Single core cable: 20 (D+d) ±5% mm;
Multi-core cable: 15(D+d) ± 5% mm;
Formula inside: D-Actual cable outer diameter;
d-Actual conductor outer diameter.
Table 1 Type description & application of aerial insulated cable

Type Name Application
JKTRYJ Soft copper conductor XLPE insulation aerial cable The transformer leads to connect the line
JK(L)YJ Cu (Al) copper conductor XLPE insulation aerial cable When laying fixed cable, the user must keep certain distance between cable and trees. During power transmission, allow the cable with multifarious contact in tree.
JK(L)Y Cu (Al) copper conductor HDPE insulation aerial cable
JKLGYJ Steel-Al conductor XLPE insulation aerial cable
JKLGY Steel-Al conductor HDPE insulation aerial cable
JKLYJ/Q Al conductor light XLPE insulation aerial cable When laying fixed cable, the user must keep certain distance between cable and trees. During power transmission, the cable can be allowed with trees just for a short time.
JKLY/Q Al conductor light HDPE insulation aerial cable
JKLGYJ/Q Steel-Al conductor light XLPE insulation aerial cable
JKLGY/Q Steel-Al conductor light HDPE insulation aerial cable

Table 2 Specifications of aerial insulated cable

Type Core number Nominal cross-section area mm2
1 KV 10KV
JK(L)YJ JK(L)Y
JKTRYJ JKTRY
1 16–240 25–300
3 10–120 25–300
4 10–120
JK(L)YJ/Q JK(L)Y/Q 1 ———- 25–300
JKLGYJ JKLGY 1 25/4—300/40 25/4—300/40
JKLGYJ/Q 1 ——— 25/4—300/40