Aluminum Conductor XLPE Insulated 35mm ABC Cable (3*35+54.6+1*16, NFC standard)
Product Description
Specifications
1.NFC 33209 abc cable
2.XLPE/hdpe insulated
3.aerial bundled cable
4.inner shielding layer material
5.weather-proof insulation
Overhead NFC 33209 abc cable size 3*35+54.6+16mm 3*95+54,6mm
It consists of copper or aluminum conductor; inner shielding layer, weather-proof insulation material and outer shielding layer. It not only has power transmitting character of power cable, but also has a strong mechanical character of aerial cable, as well. In comparasion with bare cable, it boasts many advantages, such as, small span in laying the initiative to choose to use.
1. Executive standard:
GB12527-90 1KV Aerial insulation cable (According to IEC502, IEC227 Standard)
GB14049-93 10KV Aerial insulation cable
2. Working conditions of aerial insulation power cable:
1) Rated voltage: 1KV, 10KV
2) The highest working temperature of the cable conductor:
XLPE insulation cable: 90°C
HDPE insulation cable: 75°C
3) During having a short circuit (lasting less than 5 seconds), the maximum temperature:
XLPE insulation cable: 250°C
HDPE insulation cable: 150°C
4) During laying the cable, the ambient temperature must be above -20°C.
5) Bending radius allowance of the cable:
A) 1 KV aerial insulation power cable;
It should be no less than 4D for the cable with outer diameter less than 25mm;
It should be no less than 4D for the cable with outer diameter of than 25mm;
B) 10KV aerial insulation power cable:
Single core cable: 20 (D+d) ±5% mm;
Multi-core cable: 15(D+d) ± 5% mm;
Formula inside: D-Actual cable outer diameter;
d-Actual conductor outer diameter.
Table 1 Type description & application of aerial insulated cable
Type | Name | Application |
JKTRYJ | Soft copper conductor XLPE insulation aerial cable | The transformer leads to connect the line |
JK(L)YJ | Cu (Al) copper conductor XLPE insulation aerial cable | When laying fixed cable, the user must keep certain distance between cable and trees. During power transmission, allow the cable with multifarious contact in tree. |
JK(L)Y | Cu (Al) copper conductor HDPE insulation aerial cable | |
JKLGYJ | Steel-Al conductor XLPE insulation aerial cable | |
JKLGY | Steel-Al conductor HDPE insulation aerial cable | |
JKLYJ/Q | Al conductor light XLPE insulation aerial cable | When laying fixed cable, the user must keep certain distance between cable and trees. During power transmission, the cable can be allowed with trees just for a short time. |
JKLY/Q | Al conductor light HDPE insulation aerial cable | |
JKLGYJ/Q | Steel-Al conductor light XLPE insulation aerial cable | |
JKLGY/Q | Steel-Al conductor light HDPE insulation aerial cable |
Table 2 Specifications of aerial insulated cable
Type | Core number | Nominal cross-section area mm2 | |
1 KV | 10KV | ||
JK(L)YJ JK(L)Y JKTRYJ JKTRY |
1 | 16–240 | 25–300 |
3 | 10–120 | 25–300 | |
4 | 10–120 | ||
JK(L)YJ/Q JK(L)Y/Q | 1 | ———- | 25–300 |
JKLGYJ JKLGY | 1 | 25/4—300/40 | 25/4—300/40 |
JKLGYJ/Q | 1 | ——— | 25/4—300/40 |
- Next: Flexible Flat Cable for Elevator Use 4X6mm2
- Previous: 600/1000V, Power Cable, XLPE, 4core (3+1) , 3X95+70mm2
Contact us
Similar Or Related
-
600/1000V AAC Conductor PE Insulated Duplex Service Drop Aerial Cable
-
Duplex Service Drop Aerial Bundled Cable XLPE Insulated ABC Cable
-
Aluminum Conductor Duplex Service Drop PE Insulated ABC Cable
-
Shepherd Core XLPE Insulation Duplex Service Drop Aerial Bounded Cable
-
Aluminium Strand Conductor Duplex Service Drop Insulated Aerial Cable
-
Aluminum Conductor XLPE Insulated 35mm ABC Cable (3*35+54.6+1*16, NFC standard)