Aluminum Conductor Twisted ABC Cable 600/1000V Overhead Cable

Aluminum Conductor Twisted ABC Cable 600/1000V Overhead Cable

Aluminum Conductor Twisted ABC Cable 600/1000V Overhead Cable

Twisted ABC Cable

Construction, Overhead, Power Station

Low and Medium Voltage Cable

DC & AC

PVC/XLPE/PE

None

Round Wire

Aluminum

ISO, CCC, CE

ABC Cable

Yifang

1core ~ 6core

Black,White,Red,or as Per Requirements

Yifang

Coil, Drum

16mm2-630mm2

Zhengzhou, Henan, China

8544492100

Product Description

Aluminum Conductor Twisted ABC Cable 600/1000V Overhead Cable

Application of xlpe abc cable

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead powerdistribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for
temporary service at construction sites, as a service drop (power pole to service entrance),as a secondary cable (pole to pole) or street lighting.

This over-head cable providesreinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140.

It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard of xlpe abc cable

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/
NZS 3560-1 standards

Construction of xlpe abc cable

Conductor: Aluminium conductor, round stranded compressed (RM).

insulation: XPLE compound, UV-resistant.
Core identification: 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores.

The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm²
and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the
surface of the protective core should be smooth.

Electrical Properties
rated Voltage0.6/1kV
Test Voltage 4 Veff kV
minimum laying Temperature -20°C
operating Temperature -40°C~ +90°C
maximum Short-circuit Temperature 250°C
maximum Conductor Temperature 80°C
minimum Bending radius 18×OD

Construction Parameters of xlpe abc cable

TNB Specification (IEC 60502)

number of cores xNominal cross Section overall diameter weight Maxinum conductor Resistance Minimun breaking Load current Rating
No.xmm2 mm kg/km Ω/Km KN A
1×16+1×25 RM 15.3 160 1,910 2,5 72
3×16+1×25 RM 19 290 1,200 4,0 107
3×25+1×25 RM 23.2 400 0,868 5,5 132
3×35+1×25 RM 25.6 500 0,641 8,0 165
3×50+1×35 RM 30 680 0,443 10,7 205
3×70+1×50 RM 34.9 920 0,320 13,7 240
3×95+1×70 RM 40.6 1270 0,253 18,6 290
3×120+1×70 RM 44.1 1510 0,206 23,2 334
3×150+1×95 RM 49.2 1870 0,164 28,7 389
3×185+1×120 RM 54.9 2340 0,125 37,2 467
3×25+1×25+1×16 RM 23.2 470 1,910 2,5 72
3×35+1×25+1×16 RM 25.6 560 1,200 4,0 107
3×50+1×35+1×16 RM 30 740 0,868 5,5 132
3×70+1×50+1×16 RM 34.9 980 0,641 8,0 165
3×95+1×70+1×16 RM 40.6 1330 0,443 10,7 205
3×120+1×70+1×16 RM 44.1 1580 0,320 13,7 240
3×150+1×95+1×16 RM 49.2 1940 0,206 23,2 334
3×185+1×120+1×16 RM 54.9 2410 1,910 2,5 72
othercross-sectionscanbeoffereduponrequest.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.