Aluminum Concentric Cable 2*6 AWG

Aluminum Concentric Cable 2*6 AWG

Aluminum Concentric Cable 2*6 AWG

2*6AWG

Jinyuan

VV

ISO, CCC

Aluminium Wire

Round Wire

PVC

PVC

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Power Station, Telecommunication

25

Red,Gray, Black

Jinyuan

Wood Drum or Steel-Wood Drum

6AWG 8AWG

China

8544492100

Product Description

Aluminum Concentric Cable 2*6 AWG
1. Application
    The cables are for the service-entrance.
2. Construction
   Rated Voltage: 600/1000V
   Conductor: Solid or stranded Al conductor
   Insulation: XLPE, PVC, PE
   Neutral conductor: Helically Al wire with coverage 100% and non-100% coverage
   External coverage: Weather resistant material, XLPE, PVC, PE 

Copper concentric cable
 
Service Entrance Cable, Type SE, In flat and In round cable, 600V
Concentric conductor with 100% and non 100% coverage
Indicidual Conductor Rated XHHW-2 or THW
Jacket and Individual Conductor Sunlight Resistant
 
1. Application
These requirements cover Type USE and USE-2 (below-ground) and Type SE (above-ground) power cable for installation in accordance with Article 338 and other applicable parts of the National Electrical Code (NEC). These cables are for the service-entrance and other (NEC) uses described in 1.4 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation. It is also appropriate for a sumersible pump cable to have a grounding conductor and for Type USE and USE-2 cables to have an insulated grounding conductor. Each insulated conductor in these cables is rated for 600V. Type USE cable has thermose insulation, except for HDPE portion of HDPE-over-XLPE insulation where used for single-conductor Type USE cable. Type USE cable has thermoset or thermoplatic insulation.
 
2. Specification
Type SE cable meets or exceeds UL Standard 44 for XHHW-2 conductors or UL 83 for THW conductors, UL Standard 854.
 
3. Construction
Type SE cable is constructed with sunlight resistant Type XHHW-2 conductor or Type THW conductors. Copper conductors are annealed (soft) copper. Cable assembly plus reinforcement tape are jacketed with sunlight resistant thermoset or thermoplastic material, available as 1 conductor with a concentric ground, 2 conductor with a round and flat or concentric round, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight resistant thermoset or thermoplastic material.

4. Type
Single core type round with full neutral entrance cable
Single core type round with less neutral entrance cable
Single core type round with full neutral and communication cores entrance cable
Two core type Flat with full neutral entrance cable
Two core type round with full neutral entrance cable
Three core type round with full neutral and communication cores entrance cable
Three core type round with less neutral entrance cable
 

Cable size
mm2
Insulation thickness mm Inner covering thickness.
mm
No. and size of concentric conductor Jacket thickness mm Overall diameter mm
1×1.5/1.5 1.5 18×0.5 1.8 9
1×2.5/2.5 1.5 13×0.5 1.8 9.5
1×4/4 1.5 14×0.6 1.8 10.1
1×6/6 1.5 21×0.6 1.8 10.6
1×10/10 1.5 26×0.7 1.8 11.6
1×16/16 1.5 25×0.9 1.8 13.5
1×25/16 1.5 25×0.9 1.8 14.8
1×35/16 1.5 25×0.9 1.8 15.9
1×50/16 1.5 25×0.9 1.8 17.3
1×70/16 1.5 25×0.9 1.8 19
1×95/16 1.6 25×0.9 1.8 21.1
1×120/16 1.6 25×0.9 1.8 22.7
1×150/25 1.8 39×0.9 1.8 24.5
1×185/25 2 39×0.9 1.8 26.9
1×240/25 2.2 39×0.9 1.8 29.7
1×300/25 2.4 39×0.9 1.9 32.7
1×400/35 2.6 55×0.9 2 36.2
1×500/35 2.8 55×0.9 2.1 40.1
2×1.5/1.5 0.8 1 8×0.5 1.8 12.5
2×2.5/2.5 0.8 1 13×0.5 1.8 13.3
2×4/4 1 1 21×0.5 1.8 15
2×6/6 1 1 21×0.6 1.8 16.2
2×10/10 1 1 26×0.7 1.8 18
2×16/16 1 1 25×0.9 1.8 21.5
3×1.5/1.5 0.8 1 8×0.5 1.8 13
3×2.5/2.5 0.8 1 13×0.5 1.8 13.8
3×4/4 1 1 21×0.5 1.8 15.7
3×6/6 1 1 21×0.6 1.8 16.9
3×10/10 1 1 26×0.7 1.8 18.9
3×16/16 1 1 25×0.9 1.8 22.6
3×25/16 1.2 1 25×0.9 1.8 26.3