Aluminum Concentric Cable 2*6 AWG
Product Description
1. Application
The cables are for the service-entrance.
2. Construction
Rated Voltage: 600/1000V
Conductor: Solid or stranded Al conductor
Insulation: XLPE, PVC, PE
Neutral conductor: Helically Al wire with coverage 100% and non-100% coverage
External coverage: Weather resistant material, XLPE, PVC, PE
Copper concentric cable
Service Entrance Cable, Type SE, In flat and In round cable, 600V
Concentric conductor with 100% and non 100% coverage
Indicidual Conductor Rated XHHW-2 or THW
Jacket and Individual Conductor Sunlight Resistant
1. Application
These requirements cover Type USE and USE-2 (below-ground) and Type SE (above-ground) power cable for installation in accordance with Article 338 and other applicable parts of the National Electrical Code (NEC). These cables are for the service-entrance and other (NEC) uses described in 1.4 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation. It is also appropriate for a sumersible pump cable to have a grounding conductor and for Type USE and USE-2 cables to have an insulated grounding conductor. Each insulated conductor in these cables is rated for 600V. Type USE cable has thermose insulation, except for HDPE portion of HDPE-over-XLPE insulation where used for single-conductor Type USE cable. Type USE cable has thermoset or thermoplatic insulation.
2. Specification
Type SE cable meets or exceeds UL Standard 44 for XHHW-2 conductors or UL 83 for THW conductors, UL Standard 854.
3. Construction
Type SE cable is constructed with sunlight resistant Type XHHW-2 conductor or Type THW conductors. Copper conductors are annealed (soft) copper. Cable assembly plus reinforcement tape are jacketed with sunlight resistant thermoset or thermoplastic material, available as 1 conductor with a concentric ground, 2 conductor with a round and flat or concentric round, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight resistant thermoset or thermoplastic material.
4. Type
Single core type round with full neutral entrance cable
Single core type round with less neutral entrance cable
Single core type round with full neutral and communication cores entrance cable
Two core type Flat with full neutral entrance cable
Two core type round with full neutral entrance cable
Three core type round with full neutral and communication cores entrance cable
Three core type round with less neutral entrance cable
Cable size mm2 |
Insulation thickness mm | Inner covering thickness. mm |
No. and size of concentric conductor | Jacket thickness mm | Overall diameter mm |
1×1.5/1.5 | 1.5 | – | 18×0.5 | 1.8 | 9 |
1×2.5/2.5 | 1.5 | – | 13×0.5 | 1.8 | 9.5 |
1×4/4 | 1.5 | – | 14×0.6 | 1.8 | 10.1 |
1×6/6 | 1.5 | – | 21×0.6 | 1.8 | 10.6 |
1×10/10 | 1.5 | – | 26×0.7 | 1.8 | 11.6 |
1×16/16 | 1.5 | – | 25×0.9 | 1.8 | 13.5 |
1×25/16 | 1.5 | – | 25×0.9 | 1.8 | 14.8 |
1×35/16 | 1.5 | – | 25×0.9 | 1.8 | 15.9 |
1×50/16 | 1.5 | – | 25×0.9 | 1.8 | 17.3 |
1×70/16 | 1.5 | – | 25×0.9 | 1.8 | 19 |
1×95/16 | 1.6 | – | 25×0.9 | 1.8 | 21.1 |
1×120/16 | 1.6 | – | 25×0.9 | 1.8 | 22.7 |
1×150/25 | 1.8 | – | 39×0.9 | 1.8 | 24.5 |
1×185/25 | 2 | – | 39×0.9 | 1.8 | 26.9 |
1×240/25 | 2.2 | – | 39×0.9 | 1.8 | 29.7 |
1×300/25 | 2.4 | – | 39×0.9 | 1.9 | 32.7 |
1×400/35 | 2.6 | – | 55×0.9 | 2 | 36.2 |
1×500/35 | 2.8 | – | 55×0.9 | 2.1 | 40.1 |
2×1.5/1.5 | 0.8 | 1 | 8×0.5 | 1.8 | 12.5 |
2×2.5/2.5 | 0.8 | 1 | 13×0.5 | 1.8 | 13.3 |
2×4/4 | 1 | 1 | 21×0.5 | 1.8 | 15 |
2×6/6 | 1 | 1 | 21×0.6 | 1.8 | 16.2 |
2×10/10 | 1 | 1 | 26×0.7 | 1.8 | 18 |
2×16/16 | 1 | 1 | 25×0.9 | 1.8 | 21.5 |
3×1.5/1.5 | 0.8 | 1 | 8×0.5 | 1.8 | 13 |
3×2.5/2.5 | 0.8 | 1 | 13×0.5 | 1.8 | 13.8 |
3×4/4 | 1 | 1 | 21×0.5 | 1.8 | 15.7 |
3×6/6 | 1 | 1 | 21×0.6 | 1.8 | 16.9 |
3×10/10 | 1 | 1 | 26×0.7 | 1.8 | 18.9 |
3×16/16 | 1 | 1 | 25×0.9 | 1.8 | 22.6 |
3×25/16 | 1.2 | 1 | 25×0.9 | 1.8 | 26.3 |
- Next: 0.6/1kv 1 Core XLPE Cable, Power Cable
- Previous: 0.6/1kv 3 Cores Cooper Core XLPE Insulated Power Cable
Contact us
Similar Or Related
-
0.6/1kv 1*10AWG+10AWG Annealed Copper Stranded XLPE Insulation PVC Sheath Concentric Cables
-
600/1000V Aluminum Conductor PE/XLPE Insulated PVC Sheath Concentric Cable
-
600/1000V Copper/Aluminum Conductor PE/XLPE Insulated PVC Sheath Concentric Cable
-
2X6/6mm Concentric Cable/XLPE Insulated Concentrica Cable/PE Insulated Concentric Cable