10mm2, 16mm2, 25mm2, 40mm2, 63mm2, 100mm2

Bare

Solid

Overhead

Aluminum

ISO9001, CE

SABS

2000ton/Month

SABS, ISO9001-2008, CQC Certificate, CE , SGS

Accord with The Request

1km

L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

xinsheng

Export Wooden Drums

Any Standard

China

Product Description

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 standard
ISO 9001 and ISO 14001. CE, SONCAP certificate
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums

Cross Section Number of Stranding Wires Diameter Linear Mass Rated Strength Max.D.C. Resistance at 20ºC
Wires Conductor
mm2 mm mm kg/km kN Ω/km
10 7 1.35 4.05 27.4 1.95 2.8633
16 7 1.71 5.12 43.8 3.04 1.7896
25 7 2.13 6.40 68.4 4.50 1.1453
40 7 2.70 8.09 109.4 6.80 0.7158
63 7 3.39 10.2 172.3 10.39 0.4545
100 19 2.59 12.9 274.8 17.00 0.2877
125 19 2.89 14.5 343.6 21.25 0.2302
160 19 3.27 16.4 439.8 26.40 0.1798
200 19 3.66 18.3 549.7 32.00 0.1439
250 19 4.09 20.5 687.1 40.00 0.1151
315 37 3.29 23.0 867.9 51.97 0.0916
400 37 3.71 26.0 1102.0 64.00 0.0721
450 37 3.94 27.5 1239.8 72.00 0.0641
500 37 4.15 29.0 1377.6 80.00 0.0577
560 37 4.39 30.7 1542.9 89.60 0.0515
630 61 3.63 32.6 1738.3 100.08 0.0458
710 61 3.85 34.6 1959.1 113.60 0.0407
800 61 4.09 36.8 2207.4 128.00 0.0361
900 61 4.33 39.0 2483.3 144.00 0.0321
1000 61 4.57 41.1 2759.2 160.00 0.0289
1120 91 3.96 43.5 3093.5 179.20 0.0258
1250 91 4.18 46.0 3452.6 200.00 0.0231
1400 91 4.43 48.7 3866.9 224.00 0.0207
1500 91 4.58 50.4 4143.1 240.00 0.0193