Al Xhhw-2, Building Wire, 600 V, Al/XLPE (UL44/ICEA S-95-658/NEMA WC70)
Product Description
XLP Insulation, 600 Volts
APPLICATION:
1. General purpose wiring for lighting and power – residential, commercial, industrial buildings in accordance with National Electrical Code, maximum conductor temperature of 90° C in wet or dry locations, 600 volts, for installation in conduit or other recognized raceways.
2. Suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less, such as isolated circuits supplying anesthetizing locations per Article 517-160 of the NEC.
3. Suitable for use as low leakage inductive (loop) vehicle detector wire in accordance with state and municipal requirements.
STANDARDS:
1. Listed by UL as Type XHHW-2 per Standard 44 for Rubber-Insulated Wires and Cables.
2. Conforms to ICEA S-95-658/NEMA WC70, utilizing Column B thicknesses.
3. Conforms to Federal Specification J-C-30B.
CONSTRUCTION:
Aluminum conductor, XLP thermosetting chemically crosslinked polyethylene insulation, surface printed.
Size | Stranding | Conductor Diameter | Insulation Thickness | Overall Diameter | Weight | Ampacity at 90C * | |
AWG | (inches) | (inches) | (inches) | LBS/1000′ | |||
AL-XHHW-8 | 8 | 7 | 0.134 | 0.045 | 0.227 | 30 | 45 |
AL-XHHW-6 | 6 | 7 | 0.169 | 0.045 | 0.262 | 42 | 60 |
AL-XHHW-4 | 4 | 7 | 0.213 | 0.045 | 0.306 | 68 | 75 |
AL-XHHW-2 | 2 | 7 | 0.268 | 0.045 | 0.361 | 86 | 100 |
AL-XHHW-1 | 1 | 7 | 0.299 | 0.550 | 0.412 | 110 | 115 |
AL-XHHW-1/0 | 1/0 | 18 | 0.335 | 0.550 | 0.449 | 134 | 135 |
AL-XHHW-2/0 | 2/0 | 18 | 0.378 | 0.550 | 0.489 | 163 | 150 |
AL-XHHW-3/0 | 3/0 | 18 | 0.423 | 0.550 | 0.536 | 200 | 175 |
AL-XHHW-4/0 | 4/0 | 18 | 0.476 | 0.550 | 0.588 | 247 | 205 |
AL-XHHW-250 | 250 | 35 | 0.520 | 0.650 | 0.653 | 296 | 230 |
AL-XHHW-300 | 300 | 35 | 0.571 | 0.650 | 0.703 | 359 | 255 |
AL-XHHW-350 | 350 | 35 | 0.614 | 0.650 | 0.749 | 401 | 280 |
AL-XHHW-400 | 400 | 35 | 0.657 | 0.650 | 0.792 | 453 | 305 |
AL-XHHW-500 | 500 | 35 | 0.736 | 0.650 | 0.869 | 556 | 350 |
AL-XHHW-600 | 600 | 58 | 0.816 | 0.800 | 0.979 | 679 | 385 |
AL-XHHW-700 | 700 | 58 | 0.877 | 0.800 | 1.040 | 782 | 420 |
AL-XHHW-750 | 750 | 58 | 0.909 | 0.800 | 1.071 | 833 | 435 |
AL-XHHW-900 | 900 | 58 | 0.999 | 0.800 | 1.162 | 987 | 480 |
AL-XHHW-1000 | 1000 | 58 | 1.059 | 0.800 | 1.223 | 1090 | 500 |
- Next: Fkkj, Power Cable, 0.6/1 Kv, Cu/PVC/Cws/Cts/PVC (HD 603.3/IEC 60502-1)
- Previous: NFA2X, Aerial Bundled Cable (ABC) 0.6/1 Kv (VDE 0274)
Contact us
Similar Or Related
-
Flexible Electric Cable V/J 1X70mm2 Copper PVC Insulated Wire for 90kV HV Substation
-
#4AWG XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
300MCM XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
6181Y 1X16mm2 PVC Insulated and Sheathed Wiring Cable BS 6004 300/500V
-