Aerial Bunched XLPE Aluminum Cables 2X10, 2X16 Sqmm ABC Cable
Product Description
Application
The cable is designed to be used in three-phase alternating networks with efficient earthing of the centre. Installation in the air for overhead lines suspended on poles etc. The cable has to be unwound from a cable reel over rollers and drawn for all cores. Unwinding on the ground is not permitted. Left-handed twist of cores. Installation of the product should only be carried out by personnel trained and qualified for electrical works. The product is designed according to recognized standards. Applicable rules of installation must be applied at all times.
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
STANDARDS
IEC60502, NFC 33 209, AS/NZS 3560.1, TP-KK-021/96, SN 347614-3A
Construction:
Aluminium conductor, Polyethylene (PE) or Crosslinked polyethylene (XLPE) insulation.
Characteristics
CONSTRUCTION CHARACTERISTICS | |
---|---|
Conductor material | Aluminum |
Insulation | XLPE |
ELECTRICAL CHARACTERISTICS | |
Rated Voltage Uo/U (Um) | 0.6/ 1 (1.2) kV |
USAGE CHARACTERISTICS | |
Maximum operating temperature | 80°C |
SPECIFIC CHARACTERISTICS | |
|
Docs and info
Al Aerial Bundled cables (ABC)
No. of cores and cross-section |
Shape of conductor |
Nominal insulation thickness |
Diameter approx. |
Cable mass approx. |
Bending radius | DC resistance at 20 °C (min.) |
Current carrying cap. in air |
mm2 | mm | mm | kg/km | mm | ohm/km | A | |
2×16 | RMV | 1.2 | 14 | 131 | 168 | 1.91 | 59 |
2×25 | RMV | 1.4 | 17 | 200 | 204 | 1.2 | 85 |
2×35 | RMV | 1.4 | 20 | 267 | 240 | 0.868 | 106 |
3×16 | RMV | 1.2 | 16 | 198 | 192 | 1.91 | 59 |
3×25 | RMV | 1.4 | 19 | 301 | 228 | 1.2 | 85 |
3×35 | RMV | 1.4 | 21 | 402 | 252 | 0.868 | 106 |
4×16 | RMV | 1.2 | 17 | 265 | 204 | 1.91 | 59 |
4×25 | RMV | 1.4 | 21 | 403 | 252 | 1.2 | 85 |
4×35 | RMV | 1.4 | 24 | 537 | 288 | 0.868 | 106 |
4×50 | RMV | 1.6 | 27 | 707 | 324 | 0.641 | 133 |
4×70 | RMV | 1.6 | 31 | 971 | 372 | 0.443 | 170 |
4×95 | RMV | 1.8 | 37 | 1322 | 444 | 0.32 | 196 |
4×120 | RMV | 1.8 | 40 | 1620 | 480 | 0.253 | 240 |
4×50+16 | RMV | 1.6/1.2 | 27 | 772 | 324 | 0.641 | 133 |
4×50+25 | RMV | 1.6/1.4 | 27 | 807 | 324 | 0.641 | 133 |
4×70+16 | RMV | 1.6/1.2 | 31 | 1036 | 372 | 0.443 | 170 |
4×70+25 | RMV | 1.6/1.4 | 31 | 1071 | 372 | 0.443 | 170 |
4×95+16 | RMV | 1.8/1.2 | 37 | 1387 | 444 | 0.32 | 196 |
4×95+25 | RMV | 1.8/1.4 | 37 | 1422 | 444 | 0.32 | 196 |
4×120+16 | RMV | 1.8/1.2 | 40 | 1685 | 480 | 0.253 | 240 |
4×120+25 | RMV | 1.8/1.4 | 40 | 1719 | 480 | 0.253 | 240 |
This data was prepared for informational purposes only and does not contain any representations, legally binding declarations or guarantees. Contractual obligations shall only come into effect after a written contract, detailing the terms and conditions, has been signed. A liability of Hongda cables for the correctness of the information contained herein is excluded. The data shall not be handed out to third parties or disclosed in public documents. Any intellectual property rights remain with Hongda cables and are reserved.