ACSR Goat Conductor for Overhead High Voltage Transmission Line

ACSR Goat Conductor for Overhead High Voltage Transmission Line

ACSR Goat Conductor for Overhead High Voltage Transmission Line

ACSR Goat

Jinyuan

ACSR

ISO, CCC, CE, RoHS, VDE

Aluminum

Round Wire

None

Bare

DC Cable

Low and Medium Voltage Cable

Overhead

IEC,ASTM,BS,DIN,GB/T

100% Test

Low Voltage, Medium Vlotage High Voltage

Manufacturer

One Year

15 Days

Power Station,Transmission & Distribution Line

Free Sample Is Avaliable

HuaTong

Wooden Drum; Wooden Steel Drum; All Steel Drum

ACSR Goat

China

7649100000

Product Description

1. Bare Overhead Conductor ACSR, AAC, AAAC Conductor
 
(1).By what other names are Aluminium Conductors known?
AAC, AAAC, ACSR are also known as Overhead Conductors, Transmission Conductors and Power Distribution Conductors. AAC is also known as aluminium stranded conductor. These cables can also be recognised by their full names of All Aluminium Conductor (AAC), All Aluminium Alloy Conductor (AAAC) an Aluminium Conductor Steel Reinforced (ACSR).
 
(2). What are Aluminium Conductors used for?
Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution.
The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity.
 
AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to.
 
AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.
 
(3). What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
 
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
 
In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.
 
(4). What do ACSR, AAC and AAAC Conductors have in common?
ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.
Standards
Our Bare conductor can meet or exceedthe item of cable international standards.
such as:
    AAC :  IEC 61089, ASTM B231, BS 215 part1, DIN 48201 etc.
  AAAC :  IEC 61089, ASTM B399, BS EN50183, BS 3242, DIN 48201 etc.
  ACSR :  IEC61089, ASTM B232, BS 215 part2, DIN 48204 etc.
  ACAR :  ASTM B524, IEC 61089 etc.
AACSR : ASTM B711, DIN 48206, IEC 61089 etc.
Aslo we accept the OEM and the new design cable as customers.
 
2. Type & Designation

Type Description No. of Wire Section Area (mm2)
AAC All Aluminum Conductor 7~127 16~1500
AAAC All Aluminum Alloy Conductor 7~91 17~1300
ACSR Aluminum Conductors Steel Reinforced 7~103 16~1250
AACSR Aluminum Alloy Conductors Steel Reinforced 7~103 16~1250
ACAR/AW Aluminum Conductors Aluminum Alloy Reinforced 7~103 16~1250
ACSW/S Aluminum Conductor Aluminum Clad Steel Wire/Strand 7~103 16~1250
GSW Galvanized Steel Wire 3/2.64~37/4.55 16.41~765.99

3 .Applications
Conductor(AAC,AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2.Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
 
4.Technical details
 
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
 

Code number Area Number of wires Wire    diameter Conductor diameter Linear mass Rated strength D.C. resistance at 20oC
mm2 No. mm mm kg/km kN Ω/km
16 15.9 7 1.7 5.1 43.4 3.02 1.7986
25 24.2 7 2.1 6.3 66.3 4.36 1.1787
35 34.4 7 2.5 7.5 93.9 6.01 0.8317
50 49.5 7 3 9 135.2 8.41 0.5776
50 48.3 19 1.8 9 132.9 8.94 0.5944
70 65.8 19 2.1 10.5 180.9 11.85 0.4367
95 93.3 19 2.5 12.5 256.3 16.32 0.3081
120 117 19 2.8 14 321.5 19.89 0.2456
150 147.1 37 2.25 15.8 405.7 26.48 0.196
185 181.6 37 2.5 17.5 500.9 31.78 0.1588
240 242.5 61 2.25 20.3 671.1 43.66 0.1193
300 299.4 61 2.5 22.5 828.5 52.4 0.0966

 
ACSR Technical Characteristics Based on Standard BS 215-2  
 

Code name Nominal aluminium area Stranding and wire    diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

 
 AAAC Technical Characteristics Based on Standard BS 3242 
 

Code name Nominal aluminium area Stranding and wire    diameter Sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
mm2 No./mm mm2 mm kg/km Ω/km kN
ALMOND 25 7/2.34 30.1 7.02 82 1.094 8.44
CEDAR 30 7/2.54 35.47 7.62 97 0.9281 9.94
FIR 40 7/2.95 47.84 8.85 131 0.688 13.4
HAZEL 50 7/3.30 59.87 9.9 164 0.5498 16.8
OAK 100 7/4.65 118.9 13.95 325 0.2769 33.3
ASH 150 19/3.48 180.7 17.4 497 0.183 50.65
ELM 175 19/3.76 211 18.8 580 0.1568 59.1
UPAS 300 37/3.53 362.1 24.71 997 0.09155 101.5

5. FAQ
(1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please
call us or tell us in your e-mail so that we will regard your inquiry priority.
 
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight
charge should be paid.
 
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7
days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.
 
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is
delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months
before the date you would like to get the products at your country.

6. Why Choose Us– Jinyuan Cable Inc
(1)More than 30 years experience.
(2)100,000m² factory,200 staffs,annual output 100,000 metic tons.
(3)Sound Quality Control
   1) Material inspection;
   2) manufacturing inspection;
   3) Finished products inspection;
   4) Inspection before delivery.
   5) Third party inspection.
   6) Inspection of storage at port of departure.
(4)ISO Certificated.
(5)Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6)24/7 service.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.