ACSR, Conductor, Aluminium Conductors Steel Reinforced (NF C 34-120)

ACSR, Conductor, Aluminium Conductors Steel Reinforced (NF C 34-120)

ACSR, Conductor, Aluminium Conductors Steel Reinforced (NF C 34-120)

NF C Standard ACSR

Overhead

Super-high Voltage Cable

DC Cable

Bare

Bare

Round Wire

Steel

ISO, CCC

ACSR

Boan

NF C 34-120

16-1250 mm2

12-85

2

DingAn

Heated Steel-Wooden Drum/Wooden Drum

SGS

Jiangsu Yixing, China

76141000

Product Description

ACSR, Conductor, Aluminium Conductors Steel Reinforced (NF C 34-120)
1. Applications
ACSR have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

2. Service Performance
(1). The permissible long-time operating temperature for aerial conductor is 70oC.
(2). Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3). When connecting conductors, the conductor beside the connecting tube cant be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4). Under installaion, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.

3. Product Performance

(1). The electrical performance of AAC and ACSR is indicated in DCΩ /km(20oC). The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ . M of international standard value.
(2). The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min. Tensile of corresponding size specified in the standard for aluminum wire.
(3). The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.
A. The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min. Tensile strength of corresponding size specified in the standard for aluminum wire.
B. The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.

4. Referred Standard
BoanCable is able to manufacture ACSR according to different stands, as below:
(1). ASTM B 232/B 232M:Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
(2). AS 3607:Conductors-Bare overhead, aluminium and aluminium alloy-Steel reinforced
(3). IEC 61089:Round wire concentric lay overhead electrical conductors
(4). DIN 48.204:Steel reinforced aluminium stranded conductor
(5). BS 215-2:Aluminium conductors and aluminium conductors, steel-reinforced-For overhead power transmission-Part 2:Aluminium conductors, steel-reinforced
(6). BS EN 50182:Conductors for overhead lines-Round wire concentric lay stranded conductors
(7). Production can be arranged according to customers requirements’ for material standard, etc.

Code Cross. Section Stranding & Wire ø Overall ø Weight Rated strength Electr.resist. at 20ºC
(mm2) (Nºx mm) (mm) (kg/km) (KN) (ohm/km)
Al Ac Total Al Ac
CANNA 37.7 28.27 9.42 37.69 9×2.00 3×2.00 8.3 155 15.4 1.02
CANNA 59.7 37.7 21.99 59.69 12×2.00 7×2.00 10 276 30.5 0.765
CANNA 75.5 47.71 27.83 75.54 12×2.25 7×2.25 11.25 348 38.4 0.605
CANNA 116.2 94.25 21.99 116.24 30×2.00 7×2.00 14 432 41.45 0.306
CANNA 116.2 94.25 21.99 116.24 30×2.00 7×2.00 14 432 47.4 0.306
CANNA 147.1 119.28 27.83 147.11 30×2.25 7×2.25 15.75 547 52.6 0.243
CANNA 147.1 119.28 27.83 147.11 30×2.25 7×2.25 15.75 547 59.5 0.243
CANNA 181.6 147.26 34.36 181.62 30×2.50 7×2.50 17.5 675 62.6 0.197
CANNA 181.6 147.26 34.36 181.62 30×2.50 7×2.50 17.5 675 72.9 0.197
CANNA 228.0 184.72 43.1 227.82 30×2.80 7×2.80 19.6 848 77.1 0.157
CANNA 228.0 184.72 43.1 227.82 30×2.80 7×2.80 19.6 848 90 0.157
CANNA 288.0 223.8 54.55 288.35 30×3.15 7×3.15 22.05 1.074 96.9 0.1225
CANNA 288.0 233.8 54.55 288.35 30×3.15 7×3.15 22.05 1.074 113.2 0.1225
CANNA 297.0 321.67 75.54 297.21 36×2.80 19×2.25 22.45 1.218 139.5 0.1305
CANNA 412.0 325.72 85.95 411.67 32×3.60 19×2.40 26.4 1.593 169.6 0.0898
CANNA 612.0 507.83 104.79 612.62 66×3.13 19×2.65 32.2 2.241 231.5 0.0566
CANNA 865.0 717.33 148.06 865.39 66×3.72 19×3.15 38.1 3.174 319 0.0405

Tags: , ,