ABC-PVC/XLPE Insulated Aerial Bundled Cable for Factory Price

ABC-PVC/XLPE Insulated Aerial Bundled Cable for Factory Price

ABC-PVC/XLPE Insulated Aerial Bundled Cable for Factory Price

Aerial Bundled Cable

Jinyuan

ISO9001, CE, CCC, RoHS

Oveahead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

ABC-PVC/XLPE Insulated Aerial Bundled Cable for factory price
1. Application
0.6/1KV AAC/AAAC/ACSR XLPE/PE Insulation ABC cable AAAC conductor has been widely used in power transmission lines and electricity distribution lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Standard
We can produce as per the standard of GB, IEC, ASTM,DIN,CSA,JIS and also particularly customize and manufacture according to your special requirement.
Standards / Testing Specifications
IEC 61089, BS 3242, DIN 48201, ASTM B399, BS EN50183, GB/T 1179-2008
Working conditions aerial insulation power cable
1) Rated voltage: 0.6kV/1Kv
2) The tallest working temperature of the cable conductor; XLPE insulation cable: 90°C;
HDPE insulation cable: 75°C;
3) During having a short (lasting less than 5 seconds) the maximum temperature;
XLPE insulated cables is 250°C;
HDPE insulated cable is 150°C
4) During the cable lying, the ambient temperature must be above-20°C
5) Bending radius allowance of the cable;
A)1Kv aerial insulation power cable:
It should be no less than 4D for the cable with outer diameter less than 25mm;
It should be no less than 6D for the cable with outer diameter of 25mm or more;
B) 10kV aerial insulation power cable:
Single core cable: 20 (D+d)±5%mm;
Multi-core cable:15 (D+d)±%mm
Formula inside: D-Actual cable outer diameter;
d-Actual conductor outer diameterl
Standard Packaging
As provided by standards and customer’s requirement.
 

BS7884-1997
Nominal Area Stranding Diameter of conductor Linear mass Rated strength D.C. resistance at 20°C
mm2 No./mm mm Kg/km KN Ω/km
10 7/1.35 4.05 89.82 3.752 1.829
14 7/1.6 4.8 126.2 5.627 1.30300
16 3/2.65 5.72 148.30 6.194 1.10600
16 7/1.7 5.10 142.40 5.946 1.15400
25 7/2.1 6.30 217.30 9.073 0.75630
32 3/3.75 8.10 296.90 12.4 0.55200
32 7/2.46 7.38 298.20 12.442 0.54970
35 7/2.5 7.50 308.00 12.86 0.53370
50 7/3.00 9.00 443.50 18.52 0.37060
50 19/1.8 9.00 435.80 17.7 0.38190
70 7/3.55 10.65 621.10 25.93 0.26460
70 19/2.1 10.50 593.20 24.09 0.28060
95 19/2.5 12.50 840.70 34.14 0.19800
100.0 7/4.3 12.90 911.20 36.54 0.18100
120.0 19/2.8 14.00 1055.00 42.83 0.15780
125.0 19/2.9 14.50 1131.00 45.94 0.14710
150.0 19/3.2 16.00 1377.00 55.94 0.12080
150.0 37/2.25 15375.00 1334.00 53.88 0.12640
185.0 19/3.55 17.75 1695.00 68.86 0.09815
185.0 37/2.5 17.75 1647.00 66.49 0.10240
Phase Phase Phase Approx.Overall Diameter Max. D.C. Resistance of Conductor at 20 Centigrade
AAC+UV-XLPE Compact Conductor UV-XLPE Insulation
No.X Normal Cross Section of Cores No.of Al Wires Overall Diameter Normal Thickness Min. Diameter
No. X mm 2 mm mm mm mm mm ohm/km
1 X 10 7 4.05 1.0 0.8 6.05 6.05 3.08
1 X 16 7 4.8 1.2 0.98 7.2 7.20 1.91
1 X 25 7 6 1.2 0.98 8.4 8.40 1.20
1 X 35 7 7.0 1.4 1.16 9.8 9.80 0.868
1 X 50 7 8.3 1.4 1.16 11.1 11.10 0.641
1 X 70 19 9.8 1.4 1.16 12.6 12.60 0.443
1 X 95 19 11.6 1.6 1.34 14.8 14.80 0.320
1 X 120 19 13 1.6 1.34 16.2 16.20 0.253
1 X 150 19 14.6 1.8 1.52 18.2 18.20 0.206
1 X 185 36 16.2 2.0 1.70 20.2 20.20 0.164
1 X 240 36 18.4 2.2 1.88 22.8 22.80 0.125
2 X 10 7 4.05 1.0 0.8 6.05 12.10 3.08
2 X 16 7 4.8 1.2 0.98 7.2 14.40 1.91
2 X 25 7 6 1.2 0.98 8.4 16.80 1.20
2 X 35 7 7.0 1.4 1.16 9.8 19.60 0.868
2 X 50 7 8.3 1.4 1.16 11.1 22.20 0.641
2 X 70 19 9.8 1.4 1.16 12.6 25.20 0.443
2 X 95 19 11.6 1.6 1.34 14.8 29.60 0.320
2 X 120 19 13 1.6 1.34 16.2 32.40 0.253
2 X 150 19 14.6 1.8 1.52 18.2 36.40 0.206
2 X 185 36 16.2 2.0 1.70 20.2 40.40 0.164
2 X 240 36 18.4 2.2 1.88 22.8 45.60 0.125
3 X 10 7 4.05 1.0 0.8 6.05 13.07 3.08
3 X 16 7 4.8 1.2 0.98 7.2 15.55 1.91
3 X 25 7 6 1.2 0.98 8.4 18.14 1.20
3 X 35 7 7.0 1.4 1.16 9.8 21.17 0.868
3 X 50 7 8.3 1.4 1.16 11.1 23.98 0.641
3 X 70 19 9.8 1.4 1.16 12.6 27.22 0.443
3 X 95 19 11.6 1.6 1.34 14.8 31.97 0.320
3 X 120 19 13 1.6 1.34 16.2 34.99 0.253
3 X 150 19 14.6 1.8 1.52 18.2 39.31 0.206
3 X 185 36 16.2 2.0 1.70 20.2 43.63 0.164
3 X 240 36 18.4 2.2 1.88 22.8 49.25 0.125
4 X 10 7 4.05 1.0 0.8 6.05 14.64 3.08
4 X 16 7 4.8 1.2 0.98 7.2 17.42 1.91
4 X 25 7 6 1.2 0.98 8.4 20.33 1.20
4 X 35 7 7.0 1.4 1.16 9.8 23.72 0.868
4 X 50 7 8.3 1.4 1.16 11.1 26.86 0.641
4 X 70 19 9.8 1.4 1.16 12.6 30.49 0.443
4 X 95 19 11.6 1.6 1.34 14.8 35.82 0.320
4 X 120 19 13 1.6 1.34 16.2 39.20 0.253
4 X 150 19 14.6 1.8 1.52 18.2 44.04 0.206
4 X 185 36 16.2 2.0 1.70 20.2 48.88 0.164
4 X 240 36 18.4 2.2 1.88 22.8 55.18 0.125

Construction of twisted abc cable

Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
 

Type Specification Conductor Insulation Cable Dia kg/km
Nomina Diameter No. Conductor Dia. Thickness Overall Dia. mm Aluminium XLPE kg/km
ABC 2*10 1.35 7 4 1 6 12 55.478  32.284  87.762 
2*16 1.7 7 4.9 1.2 7.3 14.6 87.974  46.805  134.779 
2*25 2.12 7 6 1.2 8.4 16.8 136.813  55.176  191.989 
2*35 2.52 7 7 1.4 9.8 19.6 193.311  74.598  267.909 
2*50 3 7 8.4 1.4 11.2 22.4 273.967  86.958  360.925 
2*70 2.52 14 10 1.4 12.8 25.6 386.622  101.083  487.705 
2*70 2.54 14 10 1.4 12.8 25.6 392.783  101.083  493.866 
2*70 2.72 12 10 1.4 12.8 25.6 386.079  101.083  487.162 
2*95 2.52 19 11.5 1.6 14.7 29.4 524.702  132.104  656.805 
2*120 2.85 19 12.9 1.6 16.1 32.2 671.121  146.168  817.289 
2*120 2.54 24 12.9 1.6 16.1 32.2 673.343  146.168  819.511 
2*150 2.58 30 14.5 1.8 18.1 36.2 868.397  184.160  1052.556 
2*170 3.38 19 15.5 2 19.5 39 943.941  219.046  1162.987 
2*170 2.52 37 15.5 2 19.5 39 1021.787  219.046  1240.833 
2*185 2.58 37 16.1 2 20.1 40.2 1071.023  226.535  1297.558 
2*240 2.96 37 18.3 2.2 22.7 45.4 1409.752  281.513  1691.266 
2*300 2.58 60 20.5 2.2 24.9 49.8 1736.794  311.651 