ABC Cable Self-Supporting with Sans1418 Standard
ABC Cable Self-Supporting with Sans1418 Standard
Overhead
Low and Medium Voltage Cable
DC & AC
PVC
PVC
Round Wire
Aluminum & Steel
ISO, CE
SABS
Jiapu
SABS, ISO9001-2008, CQC Certificate, CE , SGS
Ianjin, Qtingdao, Ningbo, Shanghai, Xiamen, Shenzh
5000km/Week
1km
Accord with The Request
Jiapu
Wooden Drums
any one
Henan China
4101962331
Product Description
Application
The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.
The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.
Construction:
Nominal Section Area: 16mm2-150mm2
Conductor: Stranded aluminum wires, compacted stranded aluminum conductor
Insulation: XLPE
Qty of Cores: Single, two, three, four
Identification Way of Cores: Printing numbers, ridge
Voltage Rating: 600/1000V
Standard: SANS1411-1, SANS1418
Phase | Phase | Phase | Approx.Overall Diameter | Min.Bending Radius | Max. D.C. Resistance | |||
AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | ||||||
No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Thickness | Min. | Diameter | |||
No. X mm2 | – | mm | mm | mm | mm | mm | kN | ohm/km |
4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 2.07 | 1.91 |
4 X 25 | 7 | 6.0 | 1.4 | 1.16 | 8.8 | 21.3 | 3.3 | 1.2 |
4 X 35 | 7 | 7.0 | 1.6 | 1.34 | 10.2 | 24.68 | 4.5 | 0.868 |
4 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 27.83 | 6.2 | 0.641 |
4 X 70 | 19 | 10.0 | 1.8 | 1.52 | 13.6 | 32.91 | 8.9 | 0.443 |
4 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 36.78 | 12.3 | 0.32 |
4 X 120 | 19 | 13.0 | 1.8 | 1.52 | 16.6 | 40.17 | 15.6 | 0.253 |
4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 19.2 | 0.206 |
3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 2.07 | 1.91 |
3 X 25 | 7 | 6.0 | 1.4 | 1.16 | 8.8 | 19.01 | 3.3 | 1.2 |
3 X 35 | 7 | 7.0 | 1.6 | 1.34 | 10.2 | 22.03 | 4.5 | 0.868 |
3 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 24.84 | 6.2 | 0.641 |
3 X 70 | 19 | 10.0 | 1.8 | 1.52 | 13.6 | 29.38 | 8.9 | 0.443 |
3 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 32.83 | 12.3 | 0.32 |
3 X 120 | 19 | 13.0 | 1.8 | 1.52 | 16.6 | 35.86 | 15.6 | 0.253 |
3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 19.2 | 0.206 |
2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 2.07 | 1.91 |
2 X 25 | 7 | 6.0 | 1.4 | 1.16 | 8.8 | 17.6 | 3.3 | 1.2 |
2 X 35 | 7 | 7.0 | 1.6 | 1.34 | 10.2 | 20.4 | 4.5 | 0.868 |
2 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 23 | 6.2 | 0.641 |
2 X 70 | 19 | 10.0 | 1.8 | 1.52 | 13.6 | 27.2 | 8.9 | 0.443 |
2 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 30.4 | 12.3 | 0.32 |
2 X 120 | 19 | 13.0 | 1.8 | 1.52 | 16.6 | 33.2 | 15.6 | 0.253 |
2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 19.2 | 0.206 |
1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 2.07 | 1.91 |
1 X 25 | 7 | 6.0 | 1.4 | 1.16 | 8.8 | 8.8 | 3.3 | 1.2 |
1 X 35 | 7 | 7.0 | 1.6 | 1.34 | 10.2 | 10.2 | 4.5 | 0.868 |
1 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 11.5 | 6.2 | 0.641 |
1 X 70 | 19 | 10.0 | 1.8 | 1.52 | 13.6 | 13.6 | 8.9 | 0.443 |
1 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 15.2 | 12.3 | 0.32 |
1 X 120 | 19 | 13.01 | 1.8 | 1.52 | 16.6 | 16.6 | 15.6 | 0.253 |
1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 19.2 | 0.206 |