AAAC Conductor 100mm2 Aluminum Alloy AAAC Conductor

AAAC Conductor 100mm2 Aluminum Alloy AAAC Conductor

AAAC Conductor 100mm2 Aluminum Alloy AAAC Conductor

AAAC Conductor 100mm2

Bare

Stranded

Overhead

Aluminum

Round Wire

ISO9001, CE, CCC, RoHS

YIFANG

Reels

China

761490

Product Description

50mm2  Aluminum Alloy AAAC Conductor

1. Application
  AAAC Conductor is used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
    1). AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
    2). The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines, when replacing the aluminum conductor steel reinforced, the AAAC can save 5-8% of the construction cost.
    3). AAAC referred to have higher strength but lower conductivity than pure aluminum being lighter, alloy conductors can sometimes be used to advantage in replace of the more conventional ACSR.2. Standard 

2. Standard
ASTM B399,  BS EN 50183,  BS 3234, DIN 48201, IEC 61089, and ect.

3. Specification

AAAC Conductor according to ASTM B399

Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
Nominal Actual
MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47

AAAC Conductor according to DIN 48201

Code number Calculated area Number of wires Diameter of wire Overall diameter of conductor Linear mass Rated tensile strength Max. DC resistance at 20ºC
mm2 mm2   mm mm kg/km daN Ω/km
16 15.89 7 1.70 5.1 43 444 2.0910
25 24.25 7 2.10 6.3 66 677 1.3703
35 34.36 7 2.50 7.5 94 960 0.9669
50 49.48 7 3.00 9.0 135 1382 0.6714
50 48.35 19 1.80 9.0 133 1350 0.6905
70 65.81 19 2.10 10.5 181 1838 0.5073
95 93.27 19 2.50 12.5 256 2605 0.3579
120 116.99 19 2.80 14.0 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.50 17.5 500 5073 0.1842
240 242.54 61 2.25 20.3 670 6774 0.1383
300 299.43 61 2.50 22.5 827 8363 0.1120
400 400.14 61 2.89 26.0 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.20 91 2.96 32.6 1732 17490 0.0540
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335

AAAC Conductor according to  EN50183

Code Name Calculated
Cross Section
No..Dia.of Wires Overall Diameter Weight Rated Strength
  mm² No./mm mm kg/km kN
Box 18.8 7/1.85 5.55 51.4 5.55
Acacia 23.8 7/2.08 6.24 64.9 7.02
Almond 30.1 7/2.34 7.02 82.2 8.88
Cedar 35.5 7/2.54 7.62 96.8 10.46
Deodar 42.2 7/2.77 8.31 115.2 12.44
Fir 47.8 7/2.95 8.85 130.6 14.11
Hazel 59.9 7/3.30 9.90 163.4 17.66
Pine 71.6 7/3.61 10.8 195.6 21.14
Holly 84.1 7/3.91 11.7 229.5 24.79
Willow 89.7 7/4.04 12.1 245,0 26.47
Oak 118.9 7/4.65 14.0 324.5 35.07
Mulberry 150.9 19/3.18 15.9 414.3 44.52
Ash 180.7 19/3.48 17.4 496.1 53.31
Elm 211.0 19/3.76 18.8 579.2 62.24
Poplar 239.4 37/2.87 20.1 659.4 70.61
Sycamore 303.2 37/3.23 22.6 835.2 89.40
Upas 362.1 37/3.53 24.7 997.5 106.82
Yew 479.0 37/4.06 28.4 1319.6 141.31
Totara 498.1 37/4.14 29.0 1372.1 146.93
Rubus 586.9 61/3.50 31.5 1622.0 173.13
Sorbus 659.4 61/3.71 33.4 1822.5 194.53
Araucaria 821.1 61/4.14 37.3 2269.4 242.24
Redwood 996.2 61/4.56 41.0 2753.2 293.88

 
AAAC Conductor according to IEC61089

Code Number A2 Conductor A3 Conductor Max.D.C. Resistance of Conductor at 20ºC
Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm mm kg/km daN mm mm kg/km daN Ω/km
16 7 1.83 5.49 50.4 5.43 7 1.84 5.52 50.8 6.04 1.7896
25 7 2.29 6.87 78.7 8.49 7 2.30 6.9 79.5 9.44 1.1453
40 7 2.89 8.67 125.9 13.58 7 2.91 8.73 127.1 15.1 0.7158
63 7 3.63 10.8 198.3 21.39 7 3.65 10.95 200.2 23.06 0.4545
100 19 2.78 13.9 316.3 33.95 19 2.79 13.95 319.3 37.76 0.2877
125 19 3.10 15.5 395.4 42.44 19 3.12 15.6 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 19 3.53 17.65 511.0 58.56 0.1798
200 19 3.93 19.65 623.7 67.91 19 3.95 19.75 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 19 4.41 22.05 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 37 3.55 24.85 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 37 4.0 28 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 37 4.24 29.68 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 37 4.47 31.29 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 61 3.69 33.21 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 61 3.91 35.19 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 61 4.15 37.35 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 61 4.4 39.6 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 91 3.83 42.13 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 91 4.03 44.33 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 91 4.27 46.97 3594.4 409.92 0 0258
1250 91 4.49 49.39 3973.7 424.41    

4. Package

Packaged by standard wooden drum, steel-wooden drum, and steel drum.

Tags: