600/1000V, Used for Substation Power Plant Power Cable, 1core 300mm2

600/1000V, Used for Substation Power Plant Power Cable, 1core 300mm2

600/1000V, Used for Substation Power Plant Power Cable, 1core 300mm2

300mm2

Construction, Underground, Power Station

Low and Medium Voltage Cable

DC & AC

XLPE

PVC

Round Wire

Red Copper Wire

ISO, CCC, CE

YJV

Yifang

up to 800mm2

up to 35kv

Swa or Sta

yifang

Wooden Drum

CE

Zhengzhou, China

8544601200

Product Description


Specifications
Power Cable
1.14years manufacture experience
2.IEC,BS standard
3.ISO certificate
4.Professional QC inspection,best service
Used for Substation,Power plant Power Cable,
300mm2
4cores

Description:
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE power cable has high electric strength, mechanical strength, high-ageing resisting, environmental stress resisting anti-chemical corrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
The flame-retardant and non-flame retardant XLPE cable can be manufactured with three technologies (peroxide, silane and irradiation cross-linking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke non-halogenated and three classes of A,B,C.

Product Description:
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kv 3.6/6kv 6/10kV 8.7/15kV 26/35kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core(Single core),two cores(Double cores),three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: IEC 60502. IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.

Application conditions:
1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.

Product List:

Type Description Application
Cu Core Al Core
YJV
ZR-YJV
YJLV
ZR-YJLV
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force.
YJV22
ZR-YJV22
YJLV22
ZR-YJLV22
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force.
YJV32
ZR-YJV32
YJLV32
ZR-YJLV32
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force.
YJV42
ZR-YJV42
YJLV42
ZR-YJLV42
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.