5kv 3X4/0+2X1+1X4AWG 8kv CPE Cable for Shd-Gc Rubber Cable Mining Cable

5kv 3X4/0+2X1+1X4AWG 8kv CPE Cable for Shd-Gc Rubber Cable Mining Cable

5kv 3X4/0+2X1+1X4AWG 8kv CPE Cable for Shd-Gc Rubber Cable Mining Cable

SHD-GC Rubber Cable

Insulated

Stranded

Portable, Mining

Copper

Rubber

Rubber

Round Wire

Mine

ISO9001, CE, UL, CCC, RoHS, VDE

Yifang

Epr

1/0AWG-500mcm

Black, Yellow

Very Flexible

Yifang cable

Drum, Steel Drum

CE, ISO, CCC

Henan Zhengzhou

8544601200

Product Description

5kV 3×4/0+2×1+1x4AWG 8KV CPE Cable for SHD-GC Rubber Cable Mining Cable

1.Application:
These cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.
2.Conductor
4/0 AWG Coated annealed copper brunched wires, rope lay stranded per ASTM B172
Extruded Strand Shield (ESS)
Extruded thermosetting semi conducting stress control layer over conductor
3.Insulation
Ethylene Propylene Rubber (EPR) insulation
4.Insulation Shield
Extruded conducting layer covered by a conducting tape and a flexible coated copper textile braid shield overall
5.Ground Check Conductor
One annealed copper rope lay stranded per ASTM B172, insulated with high strength polypropylene.
6.Grounding Conductors
Two coated copper rope lay stranded per ASTM B172, in contact with the flexible copper braid shield
7.Jacket
Reinforced, two layers, extra heavy duty, lead cured Chlorinated Polyethylene (CPE)
8. Detailed Standard
ICEA S-75-381/NEMA WC 58
ASTM B-8
CAN/CSA-C22.2 No.96

Conductors: Stranded annealed bare copper conductor.
Conductor Shield:Conducting layer.
Insulation:Ethylene Propylene Rubber (EPR).
Insulation Shield:Conducting layer + copper tape.
Ground Check Conductor:Copper conductor with a yellow polypropylene insulation.
Grounding Conductor:Tinned copper conductor.
Jacket: Chlorinated Polyethylene(CPE), black.

Construction No. of Strands Grounding Conductor Size Ground Check Conductor Size Nominal Insulation Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil AWG/kcmil AWG/kcmil inch mm inch mm inch mm lbs/kft kg/km A
3×1 19 5 8 0.260 6.4 0.14 3.6 2.37 60.2 3435 5112 187
3×1/0 19 4 8 0.260 6.4 0.14 3.6 2.45 62.2 3815 5677 218
3×2/0 19 3 8 0.260 6.4 0.14 3.6 2.54 64.5 4290 6384 249
3×3/0 19 2 8 0.260 6.4 0.14 3.6 2.65 67.3 4875 7255 286
3×4/0 19 1 8 0.260 6.4 0.14 3.6 2.81 71.4 5665 8430 327
3×250 37 1/0 8 0.260 6.4 0.17 4.3 2.97 75.4 6495 9666 360
3×350 37 2/0 8 0.260 6.4 0.17 4.3 3.18 80.8 7970 11860 438
3×500 37 4/0 8 0.260 6.4 0.17 4.3 3.45 87.6 10300 15328 536

Tags: , ,