4X35mm2, 4X50mm2, 4X70mm2, 4X95mm2 Cable Xv/Xav Power Cables

4X35mm2, 4X50mm2, 4X70mm2, 4X95mm2 Cable Xv/Xav Power Cables

4X35mm2, 4X50mm2, 4X70mm2, 4X95mm2 Cable Xv/Xav Power Cables

xv cable

Construction, Underground, Industrial, Power Station

Building

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Red Copper Wire

ISO, CCC

SGS

U-1000 RO2V, Ar2V

Hongda

NFC 32 321

0.6/1 Kv

Hongda

Drum or as Customer Require

1.5mm2 to 400mm2

China

8544492100

Product Description

U-1000 R2V/XV/RV Cable
APPLICATION: 
These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

 

Conductor: : rigid red copper / Aluminum wire class  1 (Φ ≤ 4 mm²)
: stranded circular compacted copper / Aluminum class 2 (Φ>4mm²)
Insulation : XLPE crosslinked polyethylene (no dry cool)
Bedding : PVC (Polyvinyl Chloride)
Outer sheath : PVC
Screen : no
Drain wire : no
Lead sheath : no
Concentric cond. : none
Insulation integrity : no
Circuit integrity : no
Armouring : no

 

U-1000 R2V/XV/RV Cable – Technical data and tests
Standards : NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100
Nominal voltage U0/U : 0,6/1 kV
Test voltage (50 Hz) : 4 kV
Maximun voltage Um : 1,2 kV
Maximun operating temperature : +90° C
Maximun short circuit temperature : +250° C
Min. operating temperature  
(without mechanical shocks)
: -25° C
Minimum installation and use temp. : -10° C
Minimum bending radius per  
D cable diameter (in mm)
: 6 x D
Maximum pulling stress : 5 kg/mm² (of copper cross section)
Core colours single core : black
two cores : blue-brown
three  cores : brown-black-blue  (1,5/2,5 mmq); brown-black-gray (4 mmq)  or Y/G-blue-brown)
four cores : blue-brown-black-gray (or Y/G instead blue)
five cores : blue-brown-black-gray-Y/G (or black instead Y/G)
Sheath colour : black

U-1000 R2V/XV/RV Cable – Applications
This cable is for use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required.
Presents good resistance to low temperatures and chemical agents. It can be used without additional mechanical protection in open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general.
It can be laid underground with mechanical protection constucted from slabs, tiles, or bricks. It is not recommended to lay this cable in ground flooded for more than two months per year.
With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%.
 

U-1000 AR2V / RO2V Cable – Other standards
German : N2XY / NA2XY
British : CU/XLPE/PVC
Serbian : XP 00
Turkish : YXV-U (-R)
Romanian : C2XY

U-1000 R2V
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, copper conductor, PVC outer sheath cable

 

AWG Cross Section Insulation thickness Minimum Sheath thickness Maximum Overall diameter Approx Cable weight
  mm2 mm mm mm kg/km
16 1×1.5 0.7 1.09 6.6 45
14 1×2.5 0.7 1.09 7 55
12 1×4 0.7 1.09 7.6 75
10 1×6 0.7 1.09 8.2 100
8 1×10 0.7 1.09 9.2 140
6 1×16 0.7 1.09 10.5 205
4 1×25 0.9 1.09 12.5 315
2 1×35 0.9 1.09 13.5 400
1 1×50 1 1.09 15 530
2/0 1×70 1.1 1.09 17 725
3/0 1×95 1.1 1.18 19 985
4/0 1×120 1.2 1.18 21 1260
300MCM 1×150 1.4 1.26 23 1520
500MCM 1×185 1.6 1.26 25.5 1940
750MCM 1×240 1.7 1.35 28.5 2310
  1×300 1.8 1.43 31 3200
16 2×1.5 0.7 1.43 10.5 115
14 2×2.5 0.7 1.43 11.5 145
12 2×4 0.7 1.43 13 195
10 2×6 0.7 1.43 14 265
8 2×10 0.7 1.43 16 390
6 2×16 0.7 1.43 18.5 560
4 2×25 0.9 1.43 22 850
2 2×35 0.9 1.43 24.5 1080
16 3×1.5 0.7 1.43 11 130
14 3×2.5 0.7 1.43 12.5 170
12 3×4 0.7 1.43 13.5 230
10 3×6 0.7 1.43 15 325
8 3×10 0.7 1.43 17 485
6 3×16 0.7 1.43 19.5 705
4 3×25 0.9 1.43 23.5 1080
2 3×35 0.9 1.43 26 1390
1 3×50 1 1.43 29 1840
2/0 3×70 1.1 1.52 34 2540
3/0 3×95 1.1 1.6 38.5 3430
4/0 3×120 1.2 1.69 42.5 4440
300MCM 3×150 1.4 1.86 47.5 5380
500MCM 3×185 1.6 1.94 53 6920
750MCM 3×240 1.7 2.11 59.5 8420
3×300 1.8 2.28 66 11300
16 4×1.5 0.7 1.8 11.3 180
14 4×2.5 0.7 1.8 12.2 220
12 4×4 0.7 1.8 13.3 300
10 4×6 0.7 1.8 15 420
8 4×10 0.7 1.8 17.25 630
6 4×16 0.7 1.8 18.8 900
4 4×25 0.9 1.8 23 1350
2 4×35 0.9 1.8 25.1 1750
1 4×50 1 1.9 29.1 2350
2/0 4×70 1.1 2 33.9 3400
3/0 4×95 1.1 2.1 38.4 4500
4/0 4×120 1.2 2.3 42.4 5700
300MCM 4×150 1.4 2.4 47.2 7050
500MCM 4×185 1.6 2.6 52.65 8700
750MCM 4×240 1.7 2.8 59 11400
4×300 1.8 3 64.8 14200
1 3×50+35 1 1.8 28.8 2200
2/0 3×70+50 1.1 2 33.4 3100
3/0 3×95+50 1.1 2.1 37 3950
4/0 3×120+70 1.2 2.2 41.3 5050
300MCM 3×150+70 1.4 2.3 45.1 6100
500MCM 3×185+70 1.6 2.5 50 7400
750MCM 3×240+95 1.7 2.7 55.8 9700
16 5×1.5 0.7 1.8 12.1 205
14 5×2.5 0.7 1.8 13.1 260
12 5×4 0.7 1.8 14 350
10 5×6 0.7 1.8 16.3 500
8 5×10 0.7 1.8 18.5 760
6 5×16 0.7 1.8 20.6 1100
4 5×25 0.9 1.8 25.4 1600
16 7×1.5 0.7 1.8 12.3 260
14 7×2.5 0.7 1.8 13.2 330
12 7×4 0.7 1.8 15.4 450
16 8×1.5 0.7 1.8 13.9 290
14 8×2.5 0.7 1.8 14.9 380
12 8×4 0.7 1.8 16.5 520
16 10×1.5 0.7 1.8 15.8 350
14 10×2.5 0.7 1.8 17 450
12 10×4 0.7 1.8 19 630
16 12×1.5 0.7 1.8 15.5 390
14 12×2.5 0.7 1.8 16.8 510
12 12×4 0.7 1.8 19.6 700
16 14×1.5 0.7 1.8 17 440
14 14×2.5 0.7 1.8 18.3 580
12 14×4 0.7 1.8 20.5 800
16 19×1.5 0.7 1.8 17.9 550
14 19×2.5 0.7 1.8 19.4 740
12 19×4 0.7 1.8 22.6 1050
16 24×1.5 0.7 1.8 20.7 670
14 24×2.5 0.7 1.8 23.2 900
16 30×1.5 0.7 1.8 22.6 800
14 30×2.5 0.7 1.8 24.5 1100
16 37×1.5 0.7 1.8 23.5 950
14 37×2.5 0.7 1.8 26.3 1300

 

U-1000 AR2V
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, aluminum conductor, PVC outer sheath cable

 

AWG Cross Section Insulation thickness Minimum Sheath thickness Maximum Overall diameter Approx Cable weight kg/km
  mm^2 mm mm mm Al
2 1×35 0.9 1.09 13.5 190
1 1×50 1 1.09 15 245
2/0 1×70 1.1 1.09 17 325
3/0 1×95 1.1 1.18 19 425
4/0 1×120 1.2 1.18 21 520
300MCM 1×150 1.4 1.26 23 630
500MCM 1×185 1.6 1.26 25.5 780
750MCM 1×240 1.7 1.35 28.5 990
1×300 1.8 1.43 31 1210
1×400 2 1.52 34.2 1510
1×500 2.2 1.6 38 1860
1×630 2.4 1.77 44 2400
8 2×10 0.7 1.43 16,0 275
6 2×16 0.7 1.43 18,5 360
4 2×25 0.9 1.43 22,0 530
2 2×35 0.9 1.43 24,5 640
8 3×10 0.7 1.43 17,0 300
6 3×16 0.7 1.43 19,5 400
4 3×25 0.9 1.43 23,5 600
2 3×35 0.9 1.43 26,0 750
1 3×50 1 1.43 29,0 970
2/0 3×70 1.1 1.52 34,0 1310
3/0 3×95 1.1 1.6 38,5 1730
4/0 3×120 1.2 1.69 42,5 2120
300MCM 3×150 1.4 1.86 47,5 2640
500MCM 3×185 1.6 1.94 53,0 3290
750MCM 3×240 1.7 2.11 59,5 4210
  3×300 1.8 2.28 66,0 5210
4 4×25 0.9 1.43 25,5 720
2 4×35 0.9 1.43 28,5 910
1 3×50+35 1 1.52 31,1 1130
2/0 3×70+50 1.1 1.6 36,2 1540
3/0 3×95+50 1.1 1.69 40,6 1940
4/0 3×120+70 1.2 1.86 45,4 2430
300MCM 3×150+70 1.4 1.94 49,5 2890
500MCM 3×185+70 1.6 2.11 54,4 3660
750MCM 3×240+95 1.7 2.28 61,5 4680

Packing & Shipping:

Why Choose Us ?
1. We have a large production base, and advanced production equipment 
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas

FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 10-20 days if the goods are not in stock,
it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?
A: 30% T/T in advance,70% T/T balance before shipment

*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact me Vivian Mobile:+86-18339931106 , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.