4X120 + 1X70 mm2 N2xy, Power Cable, 0.6/1 Kv, Cu/XLPE/PVC

4X120 + 1X70 mm2 N2xy, Power Cable, 0.6/1 Kv, Cu/XLPE/PVC

4X120 + 1X70 mm2 N2xy, Power Cable, 0.6/1 Kv, Cu/XLPE/PVC

n2xy

Construction, Underground, Industrial, Power Station

Local Energy Distributions

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

SGS

N2xy, Cu/XLPE/PVC

Hongda

IEC 60502

0.6/1 Kv

OEM

Drum or as Customer Require

1.5mm2 to 400mm2

China

8544492100

Product Description

4×120 + 1×70 mm2 N2xy, Power Cable, 0.6 1 Kv, Cu XLPE PVC 

Place of use
These cables have a low dielectric loss, used in Indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

N2XY CU/XLPE/PVC – Construction

 

Conductor: : rigid red copper wire, class  1 (Φ ≤ 4 mm²)
  stranded circular compacted copper class 2 (Φ>4mm²)
Insulation : XLPE crosslinked polyethylene (no dry cool) / PVC
Filler : Filler 
Outer sheath : PVC / PE

 

N2XY – Technical data and tests
Standards : NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100
Nominal voltage U0/U : 0,6/1 kV
Test voltage (50 Hz) : 4 kV
Maximun voltage Um : 1,2 kV
Maximun operating temperature : +90° C
Maximun short circuit temperature : +250° C
Min. operating temperature  
(without mechanical shocks)
: -25° C
Minimum installation and use temp. : -10° C
Minimum bending radius per  
D cable diameter (in mm)
: 8 x D
Maximum pulling stress : 5 kg/mm² (of copper cross section)
Core colours single core : black
two cores : blue-Red
three  cores : red-yellow-blue
four cores : red-yellow-blue-black
five cores : red-yellow-blue-black-green
Or as customer requirements
Sheath colour : black

N2XY CU/XLPE/PVC– Applications

This cable is for use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required.
Presents good resistance to low temperatures and chemical agents. It can be used without additional mechanical protection in open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general.
It can be laid underground with mechanical protection constucted from slabs, tiles, or bricks. It is not recommended to lay this cable in ground flooded for more than two months per year.
With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%.
 

Power cable 0.6/1 kV – Other standards
German : N2XY
British : CU/XLPE/PVC
Serbian : XP 00
Turkish : YXV-U (-R)
Romanian : C2XY

 

DIMENSIONS
Cores
number
Cross
section
mm²
Approx
conductor
diameter
mm
Insulation
medium
thickness
mm
Min. sheath
thickness
mm
Max.
external
diameter
mm
Electric
resistance at
20°C
ohm/km
Approx
cable weight
kg/km
Current
carrying
air free
A
Current
carrying
burried
A
Single core
1x 1.5 1.4 0.7 1.09 6.6 12.1 45 24 31
1x 2.5 1.8 0.7 1.09 7 7.41 55 33 41
1x 4 2.25 0.7 1.09 7.6 4.61 75 45 59
1x 6 3.05 0.7 1.09 8.2 3.08 100 58 74
1x 10 3.8 0.7 1.09 9.2 1.83 140 80 101
1x 16 4.7 0.7 1.09 10.5 1.15 205 107 128
1x 25 5.9 0.9 1.09 12.5 0.727 315 138 144
1x 35 7.1 0.9 1.09 13.5 0.524 400 169 174
1x 50 8 1 1.09 15 0.387 530 207 206
1x 70 9.6 1.1 1.09 17 0.268 725 268 254
1x 95 11.4 1.1 1.18 19 0.193 985 328 301
1x 120 13.1 1.2 1.18 21 0.153 1260 382 343
1x 150 14.6 1.4 1.26 23 0.124 1520 441 387
1x 185 16.5 1.6 1.26 25.5 0.0991 1940 506 434
1x 240 18.4 1.7 1.35 28.5 0.0754 2310 599 501
1x 300 21.1 1.8 1.43 31 0.0601 3200 693 565
1x 400 23.5 2 1.52 34.2 0.047 3931 639
1x 500 26.5 2.2 1.6 38 0.0366 5020 713
1x 630 30.1 2.4 1.69 44 0.0286 5324 785
Two cores
2x 1.5 1.4 0.7 1.43 10.5 12.1 115 26 37
2x 2.5 1.8 0.7 1.43 11.5 7.41 145 36 48
2x 4 2.25 0.7 1.43 13 4.61 195 49 63
2x 6 3.05 0.7 1.43 14 3.08 265 63 80
2x 10 3.8 0.7 1.43 16 1.83 390 86 104
2x 16 4.7 0.7 1.43 18.5 1.15 560 115 136
2x 25 5.9 0.9 1.43 22 0.727 850 149 173
2x 35 7.1 0.9 1.43 24.5 0.524 1080 185 208
Three cores
3x 1.5 1.4 0.7 1.43 11 12.1 130 23 31
3x 2.5 1.8 0.7 1.43 12.5 7.41 170 31 41
3x 4 2.25 0.7 1.43 13.5 4.61 230 42 53
3x 6 3.05 0.7 1.43 15 3.08 325 54 66
3x 10 3.8 0.7 1.43 17 1.83 485 75 87
3x 16 4.7 0.7 1.43 19.5 1.15 705 100 113
3x 25 5.9 0.9 1.43 23.5 0.727 1080 127 144
3x 35 7.1 0.9 1.43 26 0.524 1390 158 174
3x 50 8 1 1.43 29 0.387 1840 192 206
3x 70 9.6 1.1 1.52 34 0.268 2540 246 254
3x 95 11.4 1.1 1.6 38.5 0.193 3430 298 301
3x 120 13.1 1.2 1.69 42.5 0.153 4440 346 343
3x 150 14.6 1.4 1.86 47.5 0.124 5380 395 395
3x 185 16.5 1.6 1.94 53 9.91 6920 450 434
3x 240 18.4 1.7 2.11 59.5 7.54 8420 538 501
3x 300 21.1 1.8 2.28 66 6.01 11300 621 565

 

DIMENSIONS
Cores
number
Cross
section
mm²
Approx
conductor
diameter
mm
Insulation
medium
thickness
mm
Min. sheath
thickness
mm
Max.
external
diameter
mm
Electric
resistance at
20°C
ohm/km
Approx
cable weight
kg/km
Current
carrying air
free
A
Current
carrying
burried
A
Four cores
4x 1.5 1.4 0.7 1.43 12 12.1 150 23 31
4x 2.5 1.8 0.7 1.43 13 7.41 205 31 41
4x 4 2.25 0.7 1.43 14.5 4.61 280 42 53
4x 6 3.05 0.7 1.43 16 3.08 390 54 66
4x 10 3.8 0.7 1.43 18.5 1.83 590 75 87
4x 16 4.7 0.7 1.43 21 1.15 870 100 113
4x 25 5.9 0.9 1.43 25.5 0.727 1365 127 144
4x 35 7.1 0.9 1.43 28.5 0.524 1760 158 174
4x 50 8.1 1 1.52 32.5 0.387 2466 192 206
4x 70 9.7 1.1 1.6 37.5 0.268 3442 246 254
4x 95 11.4 1.1 1.69 42.5 0.193 4690 298 301
4x 120 13.1 1.2 1.86 47.5 0.153 6119 346 343
4x 150 14.6 1.4 1.94 52.5 0.124 7405 395 387
4x 185 16.5 1.6 2.11 59 9.91 8820 450 434
4x 240 18.5 1.7 2.28 66.5 7.54 11865 538 501
4x 300 21 1.8 2.45 73.5 6.01 14716 621 565
3×50 + 1×35 8 1 1.52 31.1 0.387 2160 192 206
3×70 + 1×50 9.6 1.1 1.6 36.2 0.268 3010 246 254
3×95 + 1×50 11.4 1.1 1.69 40.6 0.193 3960 298 301
3×120 + 1×70 13.1 1.2 1.86 45.4 0.153 5160 346 343
3×150 + 1×70 14.6 1.4 1.94 49.5 0.124 6150 395 387
3×185 + 1×70 16.5 1.6 2.11 54.4 9.91 7780 450 434
3×240 + 1×95 18.4 1.7 2.28 61.5 7.54 9550 538 501
Five cores
5x 1.5 1.4 0.7 1.43 13 12.1 180 23 31
5x 2.5 1.8 0.7 1.43 14.5 7.41 240 31 41
5x 4 2.25 0.7 1.43 16 4.61 335 42 53
5x 6 3.05 0.7 1.43 17.5 3.08 475 54 66
5x 10 3.8 0.7 1.43 20 1.83 720 75 87
5x 16 4.7 0.7 1.43 23 1.15 1060 100 113
5x 25 5.9 0.9 1.43 28 0.727 1645 127 144
Multicores
7x 1.5 1.4 0.7 1.43 13.5 12.1 220 15 22
7x 2.5 1.8 0.7 1.43 15 7.41 310 20.5 28
10x 1.5 1.4 0.7 1.43 16.5 12.1 310 13 18.5
10x 2.5 1.8 0.7 1.43 19 7.41 440 18 24.5
12x 1.5 1.4 0.7 1.43 17 12.1 370 12.5 18
12x 2.5 1.8 0.7 1.43 19.5 7.41 525 17 24
14x 1.5 1.4 0.7 1.43 18 12.1 430 12 17
14x 2.5 1.8 0.7 1.43 20.5 7.41 610 16 22
19x 1.5 1.4 0.7 1.43 19.5 12.1 560 10.5 15
19x 2.5 1.8 0.7 1.43 22.5 7.41 745 14.5 19.5
24x 1.5 1.4 0.7 1.43 22.5 12.1 710 10 14
24x 2.5 1.8 0.7 1.43 25.5 7.41 1000 13 18
30x 1.5 1.4 0.7 1.43 24 12.1 806 9 12.5
30x 2.5 1.8 0.7 1.43 27.5 7.41 1135 12 16.5
37x 1.5 1.4 0.7 1.43 25.5 12.1 972 8 12
37x 2.5 1.8 0.7 1.43 29.5 7.41 1350 11 15.5

Packing
A: Reel of 1500 m.
B: Reel of 1000 m.
C: Reel of 500 m.
D: Multiple Reels of 1000 m.
E – Length to the client’s requirement.

Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping Port:
Shanghai, Qingdao, Tianjin or other ports as per your requirements.

Sea freight:
FOB/C&F/CIF/DAP quotation are all available.

*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact
Vivian Yuan Mobile:+86-18339931106 , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.