Product Description

4mm, 10mm AIRDAC II CNE Cables house service connection cable
 

AIRDAC II CNE Cables

Description Cable size Phase Conductor Resistance (Ohm/km) DC @ 20 °C Phase Core Impedance (Z) (Ohm/km) Current Rating (A)*
4mm², AIRDAC II CNE Cable 4mm² 4,80 5,88 30
10mm², AIRDAC II CNE Cable 10mm² 1,90 2,34 50

House Service Connection Cable
Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified bare earth conductors. Polyethylene sheathed 600/1000V house service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS 1507 and NRS 062.

· Small overall diameter – concentric construction (SNE – Seperate Neutral Earth).
· Lower mass – due to smaller diameter – no steel wire armour
· Increased safety – reliable earthing
· Improved reliability – UV stable sheath and core insulation
· Tamper and vandal proof – unauthorised access to phase conductor inhibited by concentric layer.
· Easy strip with nylon ripcord
 

AIRDAC SNE Cables

Description Cable size Phase Conductor Resistance (Ohm/km) DC @ 20 °C Earth Size (mm²) Neutral Size (mm²)
10mm², AIRDAC SNE Cable 10mm² 1,90 7,5 10
16mm², AIRDAC SNE Cable 16mm² 1,20 10 16

House Service Connection Cable (with or without pilot cores)
Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS 1507 and NRS 063.

· Small overall diameter – concentric construction (SNE – Separate Neutral Earth).
· Lower mass – due to smaller diameter – no steel wire armour
· Increased safety – reliable earthing
· Improved reliability – UV stable sheath and core insulation and water blocked
· Tamper and vandal proof – unauthorised access to phase conductor inhibited by concentric layer.
· Easy strip with nylon ripcord