4core Copper or Aluminum XLPE Insulation Swa Armoured Electric Cable

4core Copper or Aluminum XLPE Insulation Swa Armoured Electric Cable

4core Copper or Aluminum XLPE Insulation Swa Armoured Electric Cable

4x35mm2

Construction, Power Station

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Red Copper Wire

ISO, CE

YJLV22

Jytop

4 Core X 35mm2

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Ce, ISO 9001

JYTOP

Packed in Reels

4x95mm2

Zhengzhou, China

8544601200

Product Description

Copper or Aluminum Conductor PVC/XLPE Insulation SWA Armoured Power Cable

Application :
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the XLPE Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 35kV.

Standard :
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer

Description of armoured cable :
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.

Specification

Number of the core Model Specification Main application
copper conductor aluminum conductor
single core and three core YJV
YJY
YJLV
YJLY
XLPE insulation PVC or PE sheath power cable Laying indoor tunnel, cable trench and pipe, can also be buried in loose soil, unable to bear external mechanical pressure , but can withstand a certain amount of traction laying
Single core YJV62
YJV63
YJY62
YJY63
YJLV62
YJLV63
YJLY62
YJLY63
XLPE insulation non-magnetic metal tape armored PVC or PE sheath power cabe Laying indoor, tunnel, cable trench and pipelines, can withstand the mechanical exogenous process, but unable to bear large tension
Three cores YJV22
YJV23
YJY22
YJY23
YJLV22
YJLV23
YJLY22
YJLY23
XLPE insulation steel tape armored PVC or PE sheath power cable
Single core YJV72
YJV73
YJY72
YJY73
YJLV72
YJLV73
YJLY72
YJLY73
XLPE insulation non-magnetic metal wire armored PVC or PE sheath power cable Laying in the shaft, water and under theconditions of the occasion with drop, cable can withstand mechanical exogenous process an considerable tension
Three cores YJV32
YJV33
YJY32
YJY33
YJLV32
YJLV33
YJLY32
YJLY33
XLPE insulation thin steel wire armored PVC or PE sheath power cable
Three cores YJV42
YJV43
YJY42
YJY43
YJLV42
YJLV43
YJLY42
YJLY43
XLPE insulation thick steel wire armored PVC or PE sheath power cable Laying in the water, sea, larger fall and the places need across, the thick steel wire armored cable can withstand greater tension than the thin
type core No voltage(KV)
0.6/1.0 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 21/35 26/35
conductor norminal area mm2
YJV YJV32(42) 1 1.5-30 25-630 25-630 25-400 50-500
YJLV YJLV32(42) 1 4-300 35-630 35-630 35-300 50-630
YJV22 1 2.5-300 25-500 25-500 35-500
YJLV22 1 4-300 35-500 35-500 35-500
YJV YJLV 2 1.5-240
YJV22 YJLV22 2 4-240
YJV YJV22 3 1.5-240 25-300 25-300 35-300 50-300
YJLV YJLV22 3 4-240 35-300 35-300 35-300 50-300
YJV32 YJLV32 3 25-240 25-300 35-300 35-300 50-300
YJV42 YJLV42 3 50-240 35-185 35-185 35-150 50-300
YJV YJLV YJV22 YJLV22 3+1 2.5-240
YJV YJLV YJV22 YJLV22 4 2.5-240
YJV YJLV YJV22 YJLV22 4+1 2.5-240

1. Rated voltage: Uo/U: 66kV, 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.

2. No. of core: Single-core, Three-core etc.

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.

4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.

5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.

6.The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.

7. Working Frequency Voltage Test:.

For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.