4+1 Core XLPE Insulated PVC Sheathed Power Cable

4+1 Core XLPE Insulated PVC Sheathed Power Cable

4+1 Core XLPE Insulated PVC Sheathed Power Cable

Underground

Low and Medium Voltage Cable

DC & AC

PVC

PVC

Round Wire

Red Copper Wire

ISO, CCC, CE

Jinshui

JinShui

Drum

CE, ISO, CCC, SGS

Zhengzhou Henan

Product Description

Specifications

XLPE Insulated PVC Sheathed Power Cable
1 factory price
2 high quality and fast delivery
3 OEM or customized design

4+1 Core XLPE Insulated PVC Sheathed Power Cable

1. conductor: copper

2. insulation: xlpe

3 .voltage :low

4. high quality and fast delivery

5.OEM or customized design

Rated voltage 0.6/1kV, 1.8/3kV,3.6/6kV, 6/6kV, 6/10kV, 8.7/10kV, 8.7/15kV  
Max.permissible continuous operating temperature of conductor 90 °C
Max.short –circuit temperature of conductor(5s maximum duration ) ≤250 °C
The bending radius of single-core cables ≥15 times of cable diameter
The bending radius of multi-core cables ≥10 times of cable diameter

 
Standards
International:    IEC60502
China:   GB/T12706.1-2002
 
Certificates
CCC, IQNet and more others at request
 
Spec ification s

Model Number Description Application
YJV/YJLV Copper/  Aluminum  Conductor, XLPE Insulated, PVC Sheathed Power Cable For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.
YJV22/YJLV22 Copper/  Aluminum  Conductor, Steel Tape Armored, PVC Sheathed Power Cable Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.
YJV23/YJLV23 Copper/  Aluminum  Conductor, Steel Tape Armored, PE Sheathed Power Cable
YJV32/YJLV32 Copper/  Aluminum  Conductor, XLPE Insulated, Fine Steel Wire Armored, PVC Sheathed Power Cable Apply to shafts, water and soil, able to bear the larger positive pressure.

 
 Technical data

Specification
(mm 2 )
Insulation thickness
(mm)
Sheath thickness
(mm)
O.D
(mm)
Reference weight of cable
(kg/km)
Max D.C resistance at 20°C
(Ω/km)
Recommended Current Capacity
(A)
Cu Al Cu Al Cu Al
4*4+1*2.5 0.7 1.5 14.5 331 214 4.61 7.41 34 27
4*6+1*4 0.7 1.5 15.9 435 259 3.08 4.61 43 35
4*10+1*6 0.7 1.5 18.9 649 359 1.83 3.08 60 47
4*16+1*10 0.7 1.5 21.9 965 499 1.15 1.91 83 64
4*25+1*16 0.9 2 26.2 1456 725 0.727 1.2 105 82
4*35+1*16 0.9 2 28.8 1863 882 0.524 0.868 125 100
4*50+1*25 1 2 33.4 2633 1216 0.387 0.641 160 125
4*70+1*35 1.1 2 38.8 3565 1581 0.268 0.443 200 155
4*95+1*50 1.1 2 44.1 4735 2028 0.193 0.32 245 200
4*120+1*70 1.2 2.5 49.5 5977 2512 0.153 0.253 285 220
4*150+1*70 1.4 2.5 54.1 7276 3055 0.124 0.206 325 250
4*185+1*95 1.6 3 60.5 9055 3797 0.0991 0.164 375 295
4*240+1*120 1.7 3 68.2 11567 4763 0.0754 0.125 440 345

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.