4 Core XLPE Insulation ABC Aerial Bundle Cable

4 Core XLPE Insulation ABC Aerial Bundle Cable

4 Core XLPE Insulation ABC Aerial Bundle Cable

ABC Cable

Insulated

Stranded

Overhead, Underground

Aluminum

Bare

PVC

Round Wire

Overhead

ISO9001, CCC

Rmjt

BS,DIN

RMJT

Package in Dror as Your Request

16mm2-500mm2

Henan, China

8544492100

Product Description
4 core XLPE Insulation ABC Aerial Bundle Cable

1.Application for abc aerail bundeld cable

To supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SERVICE DROP CABLE TO supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation or 90°C maximum for crosslinked polyethylene (XLP) insulated conductors.

2.Features for abc aerial bundled cable

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC or ACSR.

3.Standards for abc aerial bundled cable

Service drop cable meets or exceeds the following ASTM specifications:

  • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
  • B-231 Aluminum Conductors, Concentric-Lay-Stranded
  • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
  • B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.

SPEC

mm2

Conductor structure

Insulation

Material

Insulation

Thickness

(mm)

Approx overall diameter

(mm)

Approx weight

(kg/km)

Phase (compacted Al)

Neutral

(alloy)

No./mm

No./mm

1*16+1*16

7/1.72

7/1.72

XLPE

(HDPE)

1.2

12.5

110.1

1*25+1*25

7/2.15

7/2.15

1.2

14.9

163.9

1*35+1*35

7/2.54

7/2.54

1.4

17.5

229.0

1*50+1*50

7/2.92

7/2.92

1.4

20.1

300.0

1*70+1*70

19/2.15

19/2.15

1.4

23.6

423.2

1*95+1*95

19/2.54

19/2.54

1.6

27.6

585.4

2*16+1*16

7/1.72

7/1.72

1.2

14.2

175.8

2*25+1*25

7/2.15

7/2.15

1.2

16.7

258.4

2*35+1*35

7/2.54

7/2.54

1.4

19.7

361.2

2*50+1*50

7/2.92

7/2.92

1.4

22.5

472.1

2*70+1*70

19/2.15

19/2.15

1.4

26.1

658.3

2*95+1*95

19/2.54

19/2.54

1.6

30.5

908.2

3*16+1*16

7/1.72

7/1.72

1.2

16.3

241.5

3*25+1*25

7/2.15

7/2.15

1.2

19.1

353.6

3*35+1*35

7/2.54

7/2.54

1.4

22.5

493.5

3*50+1*50

7/2.92

7/2.92

1.4

25.7

644.1

3*70+1*70

19/2.15

19/2.15

1.4

29.7

895.2

3*95+1*95

19/2.54

19/2.54

1.6

34.6

1233.5

Code

word

AWG or kcmil

Bare Neutral Messenger

Phase conductor

Weight

Kg/km

Allowcable

Ampacities(A)

ACSR

Rated

Strength

Lbs.

AAC

Insul

Thick.mm

XLPE

PE

Number

Dia.

mm

Number

Dia.mm

Number

Dia.mm

Setter

Shepherd

Eskimo

Terrier

Chow

Bull

1*6AWG+1*6AWG

1*6AWG+1*6AWG

1*4AWG+1*4AWG

1*4AWG+1*4AWG

1*2AWG+1*2AWG

1*1/0AWG+1*1/0AWG

1

1

1

1

1

1

1.68

1.68

2.12

2.12

2.67

3.37

6

6

6

6

6

6

1.68

1.68

2.12

2.12

2.67

3.37

1190

1190

1860

1860

2850

4380

1

7

1

7

7

19

4.11

1.56

5.19

1.96

2.47

1.89

1.14

1.14

1.14

1.14

1.14

1.52

111

113

171

173

266

427

85

85

115

115

150

205

70

70

90

90

120

160

* Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201. Conductor temperature of 90C for XLP, 75’C for Poly; ambient temperatures of 40’C; emissivity 0.9; 2ft/sec. wind in sun.
* To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.