4 Core 120mm Underground Armoured PVC Power Cable

4 Core 120mm Underground Armoured PVC Power Cable

4 Core 120mm Underground Armoured PVC Power Cable

NYY NAYY N2XBY NYRGBY

Underground

Low and Medium Voltage Cable

AC Cable

PVC

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE, RoHS, UL, VDE

Yjv32

JYTOP

Power

CE Kema SABS ISO TUV CCC

Copper or Aluminum

Steel Wire

1 2 3 4 3+1 3+2

Underground

1.5-800mm2

Underground Cable

Copper or Aluminum

Global

JYTOP

Wooden Drum

IEC DIN ASTM VDE BS

China

8544492100

Product Description

4 core 120mm underground armoured pvc power cable

1 Information
a, Number of cores:
1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on.

b, Construction:
Conductor: Solid or stranded copper
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)

c, Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

d, Features
XLPE insulated power cable do not has excellent electric, mechanical properties,but also has powerful resistance against chemical corrosion,heat resistance and enviromental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is conveninet to use and can be laid with no restriction of different level.

XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.

Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of A, B, C.

2 Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.

3 The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35

4 Application:
1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
2) For laying in ground along route with large difference of level able to bear external mechanical forces.

5. Specification:

Type

Designation

Application

YJV

Copper conductor ,xlpe insulated ,PVC sheathed power cable

For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct

YJLV

Aluminium conductor , xlpe insulated ,PVC sheathed power cable

YJY

Copper conductor, xlpe insulated, PE sheathed power cable

YJLY

Aluminium conductor , xlpeinsulated ,PE sheathed power cable

YJV22

Copper conductor ,xlpe insulated ,steel tape armoured ,PVC sheathed power cable

For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force

YJLV22

Aluminium conductor ,xlpe insulated ,steel tape armoured ,PVC sheathed power cable

YJV23

Copper conductor ,xlpe insualted ,steel tape armoured ,PE sheathed power cable

YJLV23

Alunminium conductor ,xlpe insulated ,steel tape armoured ,PE sheathed power cable

YJV32

Copper conductor, xlpe insulated, steel wire armoured,PVC insulated power cable

For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces

YJLV32

Aluminium conductor, xlpe insulated ,steel tape armoured ,PVC sheathed power cable

YJV33

Copper conductor, xlpe insulated steel wire armoured , PE sheathed power cable

YJLV33

Aluminium conductor ,xlpe insulated , streel wire armoured ,PE sheathed power cable

Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.

Similar Or Related