4/0AWG Duplex Triplex Quadruplex Service Drop Cable

0.6/1kv overhead insulated cable
 Product Description
1. Application of Service Drop Cable: 
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 

2. Type of Service Drop Cable: 
Service Drop Cable(ABC CABLE) covers mainly three types: 
Duplex Service Drop 
Triplex Service Drop 
Quadruplex Service Drop 

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 

3. Detaild Introduction of Service Drop Cable 
3.1 Duplex Service Drop 

Applications 
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.2 Triplex Service Drop 
Applications 
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.3 Quadruplex Service Drop 
Applications 
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. 

Construction 
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
 
 
Standards: 
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors. 
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474