3×35/16mm2 N2XSEYFGBY 6/10(12)kV HIGH VOLTAGE COPPER XLPE INSULATED CABLE 

Application
They are used in cable ducts, outdoor installations, underground where the short circuit levels are high and industrial areas fed by electrical energy also these cables use where there is risk of mechanical damage.

01: Copper Conductor
02: Conductor Screen
03: XLPE Insulation
04: Insulation Screen
05: Semi-Conductive Tape
06: Copper Wire and Copper Tape Screen
07: PVC Filler
08: Binding Tape: non-hygroscopic tape
09: PVC Inner Sheath
10: Galvanised Round Steel Wire Armour
11: Binding Tape: non-hygroscopic tape
12: PVC Outer Sheath

Technical Data
 

DESCRIPTION UNIT Supplier’s Offer
GENERAL    
Cable Code   N2XSEYFGBY
Applied Standards   IEC 60502-2
Voltage Rate (U0) kV 6
Voltage Rate (U) kV 10
Max. Operating Voltage (Um) kV 12
01: Conductor    
Material Plain annealed copper (free oxygen)
Cross-Section Area mm² 35
Number & Diameter of Wires      No.*mm 7*2.56
Type of Stranding   CIRCULAR COMPACTED
Outer Diameter (Approx.) mm 7.00
Number of Core No. 3
02: Conductor Screen    
Material   Extruded semi-conductive compound
Nominal Thickness mm 0.5
Minimum Thinkness mm 0.3
Outer Diameter (Approx.) mm 8.0
03: Insulation    
Material   XLPE
Nominal Thickness mm 3.40
Minimum Thickness mm 2.96
Outer Diameter (Approx.) mm 14.80
04: Insulation Screen    
Material   Extruded semi-conductive compound
Nominal Thickness mm 0.50
Minimum Thickness mm 0.30
Outer Diameter (Approx.) mm 15.80
05: Semi-Conductive Tape    
Tape Thickness mm 0.20
06: Metallic Screen    
Material   Copper
Type   Wire & Tape
Number & Diameter of Wires No.*mm 12*0.85 (on each core)
Thickness & Width of Copper Tape mm*mm 0.10*(≥10)(on each core)
Tape for Protection mm  
Outer Diameter (Approx.) mm 17.40
Total Cross Section Area mm² 16.00
07: Filler    
Material   PVC
08: Binding Tape: non-hygroscopic tape    
Nominal Thickness mm 0.20
09: Inner Sheath    
Material   PVC
Nominal Thickness mm 1.40
Minimum Thickness mm 0.92
10: Metallic Armour    
Material   Galvanised Round Steel Wire
Number*Diameter of Wires No.*mm (32~55) * 2.50 (up to IEC standard)
Thickness of Steel Tape mm 0.30
Width of Steel Tape mm 20.00
Binding Ratio %
11: Binding Tape: non-hygroscopic tape    
Nominal Thickness mm 0.20
12: Outer Sheath    
Material   PVC
Colour   Red
Nominal Thickness mm 2.60
Minimum Thickness mm 1.88
Electrical Properties    
Test Voltage of 5 Minutes Duration kV-rms 21
Impulse Test Voltage kV-Peak 75
Continuous Current Carrying Capacity in Air at 30ºC A 182
Continuous Current Carrying Capacity in Ground at 20ºC A 182
Continuous Current Carrying Capacity in Duct A 163
     
Ambient Temperature of Air ºC 30
Soil Temperature ºC 20
Depth of Laying m 0.8
Thermal Resistivity of Soil Km/W 1.5
     
Inductance mH/km 0.385
Capacitance μF/km 0.226
Insulation Resistance MΩ/km 14629
     
Dielectric Losses (at 90ºC, 3phases) W/km 30.672
     
Max. Continuous Conductor Temperature ºC 90
Max. Conductor Temperature at Short Circuit Condition ºC 250 (5s max. duration)
     
Maximum Short-Circuit Current    
Start Temperature 90ºC, End Temperature 250ºC    
Duration of 5 seconds kA 2.24
Duration of 1 seconds kA 5.01
Duration of 0.5 seconds kA 7.08
Maximum Short-Circuit Current at Metallic Screen    
Duration of 1 seconds kA 2.048
Duration of 0.5 seconds kA 2.896
Dielectric Loss Factor    
At 90ºC(Maximum Operating Temperature)   40×10^4
     
Conductor Resistance at 20ºC Ω/km 0.5240
Conductor Resistance at 90ºC Ω/km 0.6682
Charging Current A/km 0.43
Partial Discharge (at 2 U0) pC 5.00
Other Properties    
Outer Diameter of Cable (Approx.) mm 50.60
Minimum Bending Radius mm 759
Lowest Laying Temperature ºC -5.00
Weight of Cable (Approx.) kg/km 4600
Weight of Copper (Approx.) kg/km 1125
Weight of Armour (Approx.) kg/km 1110
Drums    
Type   Steel & Wooden
Flange (Wheel) Diameter mm 2200
Barrel Diameter mm 900
Barrel Length mm 1400
Length of Cable m 1000
     
Gross Weight kg 5225