36kv Factory Price Sac Cable to Myanmar for Power Project

36kv Factory Price Sac Cable to Myanmar for Power Project

36kv Factory Price Sac Cable to Myanmar for Power Project

SAC cable

Jinyuan

ISO9001, CCC

Mine

Round Wire

XLPE

Crosslinking

Aluminum

Overhead, Underground

Stranded

Insulated

ANSI/Icea S-66-524 or IEC

100000mm2

25

Spaced Aerial Cable

Jinyuan

15days

Aluminium Wire

Black

Jinyuan

Wood Drum or Steel- Wood Drum

Aluminium 1350 and XLPE

China

8544601200

Product Description

36kv factory price Sac Cable  to Myanmar for Power Project

Description
XLPE insulated or covered aerial cable without or with conductor screen, the phase conductor may be AAC or AAAC or ACSR or Copper.
 
Operating Characteristics
Operating voltage: 10kV 15kv 24kv 25kv 35kv
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
Single core cable: not less than 20 times of the diameter of cable
Multi-core cable: not less than 15 times of the diameter of cable
 
Application
XLPE insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission and distribution, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
 
Manufacturing Standards
GB/T 14049-2008, IEC 60502-2,  ICEA S-66-524 / MEA

IF YOUR HAVE ANY INTERESTED PRODUCTS, PLS FEEL FREE TO CONTACT OUR SALES TEAM.

Basic design to IEC 60502 / AS/NZS 3599-1 standard.

Conductor Thickness of conductor  Screen mm  (Average) Thickness
 of  insulation
mm  (Nominal)
Thickness
 of  Jacket mm  (Nominal)
Overall Diameter
 
Mm
(Approx.)
Conductor resistance at 20°C
 
Ω/km
(Max.)
Insulation resistance at 15.6°C
 
MΩ*km
(Min.)
Conductor Weight Breaking strength
 
N
(Min)
Current rating in free air at 40°C ambient A
 
Cable weight
 
Kg/km
(Approx.)
Cross-
sectional
area
mm2
(Nominal)
Number
 of o
 wires
 (Min.)
Diameter
 of i
conductor
mm
(Approx.)
35 6 6.88 0.3 3.175 3.175 21.0 0.868 2580 94 5591 150 381  
50 6 7.92 0.3 3.175 3.175 22.0 0.641 2380 128 7313 181 438  
70 12 9.55 0.3 3.175 3.175 23.5 0.443 2126 185 10420 225 527  
95 15 11.27 0.3 3.175 3.175 25.5 0.320 1913 256 14098 275 636  
120 15 12.68 0.3 3.175 3.175 27.0 0.253 1759 324 18518 319 734

11KV 25KV 36KV Spaced aerial cable SAC cable 95 120 150 185mm2

Part number Cross section
mm2
Stranding
mm
Approx weight kg/km Approx overall diameter Gland size mm Single cleat Nom. Max. DC-resist conductor 20°C
ohm/km
Current rating laid direct
amp
1 Core: Brown Tape
11KVPVC1X50 1 x 50 19/1.78 1,210 28.5 32 1.2 0.387 221
11KVPVC1X70 1 x 70 19/2.14 1,500 30.5 32 1.2 0.268 270
11KVPVC1X95 1 x 95 19/2.52 1,700 32.4 32 1.4 0.193 321
11KVPVC1X120 1 x 120 37/2.03 2,105 34.2 40 1.4 0.153 363
11KVPVC1X150 1 x 150 37/2.25 2,505 36.4 40 1.6 0.124 410
11KVPVC1X185 1 x 185 37/2.52 2,900 37.7 40 1.6 0.0991 455
11KVPVC1X240 1 x 240 61/2.25 3,532 40.6 50s 1.6 0.0754 520
11KVPVC1X300 1 x 300 61/2.52 4,230 42.7 50s 1.8 0.0601 580
1 Core: Brown Tape
11KVPVC1X400 1 x 400 61/2.85 5,145 46.4 50s 2.0 0.0470 650
11KVPVC1X500 1 x 500 61/3.20 6,450 51.0 50 2.0 0.0366 710
11KVPVC1X630 1 x 630 127/2.52 7,950 59.9 63s R9 0.0283 761
11KVPVC1X800 1 x 800 127/2.85 9,720 60.0 63 R10 0.0221 812
11KVPVC1X1000 1 x 1000 127/3.2 11,860 64.0 75s R11 0.0176 868