33kv Power Cable South Africa Standard Sans 1339

33kv Power Cable South Africa Standard Sans 1339

33kv Power Cable South Africa Standard Sans 1339

Construction, Underground, Power Station

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

YJV

Steel-Wooden Drum Packing

90mm2 150mm2 185mm2 240mm2 300mm2

China

8544601200

Product Description

Structure 
Conductor: Solid or stranded copper/Aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Armouring: Single Core: AWA (Aluminium Wire Armour)
                   Multi Core:  SWA (Steel Wire Armour)  STA (Steel Tape Armour)
Sheath: Polyvinyl chloride (PVC)

 Application
1,Long term working temperature for the cable with PVC insulated is 70ºC;
Long term working temperature for the cable with XLPE insulated is 90ºC
2,Short circuit temperature
For PVC insulated cable ,the highest conductor temperature is not more than160ºC.(lasting time not over 5 seconds).
For XLPE insulated cable ,the highest conductor temperature is not more than250ºC.(Lasting time is not over 5 seconds).
3,Laying temperature not less than 0ºC and the drop height is out of consideration.
4,The cable with chemical stability, anti- acid, anti-alkali, anti-oil, anti-organic solvent, not easy to be burning.
5,Easy for installation, easy bending and light.

Operating characteristics
– Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 00C.
– The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

Table of the voltage, cores and cross-section

Item Category    A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category    A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.
5 Type and Name

Type Designation Applications
YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV Aluminum conductor,XLPE insulated,PVC sheathed power cable
YJY Copper conductor, XLPE insulated,PE sheathed power cable
YJLY Aluminum conductor, XLPE insulated,PE sheathed power cable
YJV22 Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22 Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23 Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23 Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32 Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32 Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33 Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33 Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable

 
 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.