300/500V Mica XLPE Insulated & LSZH Sheathed Fire Alarm Cables

 (CU/MICA+XLPE/OSCR/LSZH 300/500V Class 2 )

 

APPLICATION

The cables are designed, manufactured and tested as data transmission cables for emergency services.

These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire.

STANDARDS

  • Basic design to BS 7629-1

FIRE PERFORMANCE

Circuit Integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)
System circuit integrity DIN 4102-12, E30 depending on lay system
Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1*
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2*
Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases NES 02-713; NF C 20-454

CABLE CONSTRUCTION

 

Conductor Plain annealed copper wire, stranded according to IEC 60228 class 2
Insulation Mica glass tape covered by extruded XLPE compound or cross-linked compound type EI5 as per BS 7655: section 5.1
Cabling Elements Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two-pair cable had four cores laid in quad formation
Cabling Pairs are cabled together. In cables with 8 pairs or more, 4 pairs are assembled to form a bunch, the bunches are then cabled together
Overall screen Aluminum/polyester tape with tinned copper drain wire
Inner Sheath(optional) Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 Armouring(optional): Galvanized steel wire armour
Sheath Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option

VOLTAGE RATING

300/500 V

COLOUR CODE

Insulation Colour According to IEC 60189-2 (other colour code on request)
Sheath Colour Red (other colours upon request)

PHYSICAL AND THERMAL PROPERTIES

Temperature range during operation (fixed state) -30°C – +90°C
Temperature range during installation (mobile state) -20°C – +50°C
Minimum bending radius 8 x Overall Diameter