Product Description
25/35kv Overhead Application and Aluminum Conductor Material ACSR AAC AAAC cable
1. Application
Aluminum Conductors.
Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
Construction
Conductors are concentrically stranded, AAC (1350-H19), either compressed or full compact depending on conductor size, AAAC or ACSR. Available with high-density track-resistant polyethylene (HDTRPE) or Track-Resistant Crosslinked Polyethylene (XLPE) covering. Strand shield option available as shown in illustration.
Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; However, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; Particularly useful in congested areas such as alleyways or tight corridors.
Specifications
15kV – 35kV covered multi-layer tree wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: ASTM B230 ASTM B231 ASTM B232 ASTM B398 ASTM B399 ASTM B400
1. Application
Aluminum Conductors.
Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
Construction
Conductors are concentrically stranded, AAC (1350-H19), either compressed or full compact depending on conductor size, AAAC or ACSR. Available with high-density track-resistant polyethylene (HDTRPE) or Track-Resistant Crosslinked Polyethylene (XLPE) covering. Strand shield option available as shown in illustration.
Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; However, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; Particularly useful in congested areas such as alleyways or tight corridors.
Specifications
15kV – 35kV covered multi-layer tree wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: ASTM B230 ASTM B231 ASTM B232 ASTM B398 ASTM B399 ASTM B400
3-Layer 25kV AAAC Tree Wire | |||||||||
Size | Equivalent | Conductor Diameter | Covering Thickness (mils) | Cable O.D. | Rated Strength | Weight per 1000 ft. | |||
(kcmil) | AAC (AWG or kcmil) | Stranding | (mils) | Conductor Shield | Inner Layer | Outer Layer | (mils) | (lbs) | (lbs) |
48.69 | 4 | 7 | 250 | 15 | 125 | 125 | 780 | 1584 | 225 |
77.47 | 2 | 7 | 316 | 15 | 125 | 125 | 846 | 2520 | 275 |
123.3 | 1/0 | 7 | 398 | 15 | 125 | 125 | 928 | 4014 | 348 |
155.4 | 2/0 | 7 | 447 | 15 | 125 | 125 | 977 | 4851 | 396 |
195.7 | 3/0 | 7 | 502 | 15 | 125 | 125 | 1032 | 6111 | 454 |
246.9 | 4/0 | 7 | 563 | 15 | 125 | 125 | 1093 | 7704 | 525 |
312.8 | 266.8 | 19 | 642 | 15 | 125 | 125 | 1172 | 9900 | 611 |
394.5 | 336.4 | 19 | 720 | 15 | 125 | 125 | 1251 | 11970 | 716 |
465.4 | 397.5 | 19 | 783 | 15 | 125 | 125 | 1313 | 14040 | 805 |
559.5 | 477 | 19 | 858 | 20 | 125 | 125 | 1398 | 16920 | 932 |
652.4 | 556.5 | 19 | 927 | 20 | 125 | 125 | 1467 | 19710 | 1044 |
740.8 | 636 | 37 | 990 | 20 | 125 | 125 | 1530 | 21960 | 1148 |
927.2 | 795 | 37 | 1108 | 20 | 125 | 125 | 1648 | 27450 | 1389 |
3-Layer 35kV AAAC Tree Wire | |||||||||
Size | Equivalent | Conductor Diameter | Covering Thickness (mils) | Cable O.D. | Rated Strength | Weight per 1000 ft. | |||
(kcmil) | AAC (AWG or kcmil) | Stranding | (mils) | Conductor Shield | Inner Layer | Outer Layer | (mils) | (lbs) | (lbs) |
48.69 | 4 | 7 | 250 | 15 | 175 | 125 | 880 | 1584 | 278 |
77.47 | 2 | 7 | 316 | 15 | 175 | 125 | 946 | 2520 | 333 |
123.3 | 1/0 | 7 | 398 | 15 | 175 | 125 | 1028 | 4014 | 411 |
155.4 | 2/0 | 7 | 447 | 15 | 175 | 125 | 1077 | 4851 | 462 |
195.7 | 3/0 | 7 | 502 | 15 | 175 | 125 | 1132 | 6111 | 523 |
246.9 | 4/0 | 7 | 563 | 15 | 175 | 125 | 1193 | 7704 | 598 |
312.8 | 266.8 | 19 | 642 | 15 | 175 | 125 | 1272 | 9900 | 689 |
394.5 | 336.4 | 19 | 720 | 15 | 175 | 125 | 1351 | 11970 | 799 |
465.4 | 397.5 | 19 | 783 | 15 | 175 | 125 | 1412 | 14040 | 892 |
559.5 | 477 | 19 | 858 | 20 | 175 | 125 | 1498 | 16920 | 1024 |
652.4 | 556.5 | 19 | 927 | 20 | 175 | 125 | 1567 | 19710 | 1141 |