25/35kv Overhead Application and Aluminum Conductor Material ACSR AAC AAAC  cable
1. Application
Aluminum Conductors.
Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
 Construction
Conductors are concentrically stranded, AAC (1350-H19), either compressed or full compact depending on conductor size, AAAC or ACSR. Available with high-density track-resistant polyethylene (HDTRPE) or Track-Resistant Crosslinked Polyethylene (XLPE) covering. Strand shield option available as shown in illustration.
Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; However, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; Particularly useful in congested areas such as alleyways or tight corridors.
Specifications
15kV – 35kV covered multi-layer tree wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: ASTM B230 ASTM B231 ASTM B232 ASTM B398 ASTM B399 ASTM B400

3-Layer 25kV AAAC Tree Wire
Size Equivalent   Conductor Diameter   Covering Thickness (mils)   Cable O.D. Rated Strength Weight per 1000 ft.
(kcmil) AAC (AWG or kcmil) Stranding (mils) Conductor Shield Inner Layer Outer Layer (mils) (lbs) (lbs)
48.69 4 7 250 15 125 125 780 1584 225
77.47 2 7 316 15 125 125 846 2520 275
123.3 1/0 7 398 15 125 125 928 4014 348
155.4 2/0 7 447 15 125 125 977 4851 396
195.7 3/0 7 502 15 125 125 1032 6111 454
246.9 4/0 7 563 15 125 125 1093 7704 525
312.8 266.8 19 642 15 125 125 1172 9900 611
394.5 336.4 19 720 15 125 125 1251 11970 716
465.4 397.5 19 783 15 125 125 1313 14040 805
559.5 477 19 858 20 125 125 1398 16920 932
652.4 556.5 19 927 20 125 125 1467 19710 1044
740.8 636 37 990 20 125 125 1530 21960 1148
927.2 795 37 1108 20 125 125 1648 27450 1389
3-Layer 35kV AAAC Tree Wire
Size Equivalent   Conductor Diameter Covering Thickness (mils) Cable O.D. Rated Strength Weight per 1000 ft.
(kcmil) AAC (AWG or kcmil) Stranding (mils) Conductor Shield Inner Layer Outer Layer (mils) (lbs) (lbs)
48.69 4 7 250 15 175 125 880 1584 278
77.47 2 7 316 15 175 125 946 2520 333
123.3 1/0 7 398 15 175 125 1028 4014 411
155.4 2/0 7 447 15 175 125 1077 4851 462
195.7 3/0 7 502 15 175 125 1132 6111 523
246.9 4/0 7 563 15 175 125 1193 7704 598
312.8 266.8 19 642 15 175 125 1272 9900 689
394.5 336.4 19 720 15 175 125 1351 11970 799
465.4 397.5 19 783 15 175 125 1412 14040 892
559.5 477 19 858 20 175 125 1498 16920 1024
652.4 556.5 19 927 20 175 125 1567 19710 1141

 