22kv XLPE Insulated Sta Armoured Cable

22kv XLPE Insulated Sta Armoured Cable

22kv XLPE Insulated Sta Armoured Cable

YJV22 Single core 95mm2

Insulated

Stranded

Underground

Copper or Aluminum

PVC or PE or Other Types

XLPE

Round Wire

Power Station

ISO9001, CCC

Yifang

Black or Red

1 or 3

Yifang

Drum or Under Clients' Request

ISO

China

854449210

Product Description

Medium Voltage XLPE cable N2XSY cable cu / xlpe /pvc cable

Conductor material: Bare copper

Conductor construction: Stranded, class 2

Insulation: XLPE

Sheathing material: PVC

Colour of outer sheath: Red or other

Flame retardant: VDE 0482-332-1-2/IEC 60332-1

Maximum temperature at 90 ° C
Conductor:

Max. Operating temperature, +70 ° C
Fixed:

Temperature, moved/during -5 – +70 ° C
Installation:

Bending radius, fixed 15 x DA
Installation:

Partial discharge: 2 pC

N2XSY 6/10 kV N2XSY 12/20 kV N2XSY 18/30 kV
Nominal voltage Uo: 6 kV 12 kV 18 kV
Nominal voltage U: 10 kV 20 kV 30 kV
Maximum permitted 12 kV 24 kV 36 kV
Operating voltage in 3-phase
Systems:
Test voltage: 21 kV 42 kV 63 kV

Application: For installation in ground, in water, outdoors, indoors and in cable ducts for power stations, industry, and
Distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. Acc.
To VDE 0276-603 cables must be protected against direct sun irradiation.

Nominal Cross-sectional Areas:
1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2 400 mm2 500 mm2 630 mm2 800 mm2

Production Range:
Single core cable from 1.5 mm2 to 800 mm2, muli-core cable from 1.5 mm2 to 400 mm2

Operating Characteristics:
Rated power-frequency voltage u0/u: 0.6/1 KV 3.6/6KV 12/20KV 18/35KV…
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): Cross-section of conductor 300 mm2

The ambient temperature under installations should not be below 0

The bending radius of single core cable should not be less than 20 times of the cable diameter, the bending radius of multi-core cable should not be less than 15 times of the cable diameter.

Class 2 stranded conductors for single-core and multi-core cables
1 2 3 4 5 6 7 8 9 10
Nominal crosssectional area Minimum number of wires in the conductor Maximum resistance of conductor at 20ºC
Circular Circular compacted Shaped Annealed copper conductor Aluminium or aluminium alloy conductor
Cu Al Cu Al Cu Al Plain wires Metal-coated wires
mm2 Ω/KM Ω/KM Ω/KM
0.5 7 36 36.7
0.75 7 24.5 24.8
1 7 18.1 18.2
1.5 7 6 12.1 12.2
2.5 7 6 7.41 7.58
4 7 6 4.61 4.7
6 7 6 3.08 3.11
10 7 7 6 6 1.83 1.84 3.08
16 7 7 6 6 1.15 1.16 1.91
25 7 7 6 6 6 6 0.727 0.734 1.2
35 7 7 6 6 6 6 0.524 0.529 0.868
50 19 19 6 6 6 6 0.387 0.391 0.641
70 19 19 12 12 12 12 0.268 0.27 0.443
95 19 19 15 15 15 15 0.193 0.195 0.32
120 37 37 18 15 18 15 0.153 0.154 0.253
150 37 37 18 15 18 15 0.124 0.126 0.206
185 37 37 30 30 30 30 0.0991 0.1 0.164
240 37 37 34 30 34 30 0.0754 0.0762 0.125
300 61 61 34 30 34 30 0.0601 0.0607 0.1
400 61 61 53 53 53 53 0.047 0.0475 0.0778
500 61 61 53 53 53 53 0.0368 0.0369 0.0605
630 91 91 53 53 53 53 0.0283 0.0286 0.0469
800 91 91 53 53 0.0221 0.0224 0.0367
1000 91 91 53 53 0.0176 0.0177 0.0291