ABC cable

Overhead, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC & AC

XLPE

PVC

Round Wire

Aluminum, Copper and Other Kinds

ISO, CCC

ABC Cable

Rmjt

2017 Hot Selling Aerial Bundled Cable ABC Cable

Solid, Dulplex, Triplex, Quadruplex

ABC Cable

Manufacturer

Professional Manufacturer of 25 Years in China

XLPE

0.6/1kv

ISO9001-2008, ISO14001-2004, CCC, SGS, BV etc

ASTM B-230,231,232and399, Icea S-76-474; NFC 33209

Wooden Drum, Steel Drum or as Your Requirement

RMJT

Package in Drum as Your Request

95mm2, 35mm2

Henan, China

8544492100

Product Description

2017 Hot Selling Aerial Bundled Cable ABC Cable

1.Introduction
ABC aerial Cable are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. They can improves safety and reliance of electrified wire netting.

2.Construction
Phase conductors are concentrically stranded EC Grade aluminum wires, insulated with either black weather resistant cross linked polyethylene (XLPE) or polyethylene (PE). The conductor insulation is marked with longitudinal ridges for phase identification.
Neutral messengers are concentrically stranded AAC or 6201 Alloy or ACSR. Neutral messenger can either be bare or insulated, depending on ABC aerial cable design.

3.Standards(ABC aerial cable)
1). B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2). B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3). B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4). B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5). B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6). Duplex Aerial Bundled Cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

4.Type(ABC aerial cable)
Duplex ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

Triplex ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

Quadruplex ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun

5.Our company

6.FAQ

7.How to contact us

Cara Zhang | General Manager | People’s Cable Group
T: 86-371-55367868 | M: 86-18339931106
Fax: 86-371-55367868
Web: www.vwcable.com

For more details please check our website as my contact information.Thanks!

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.