2.5mm Cooper PVC Insulation PVC Jacket Electrical Building Wire

2.5mm Cooper PVC Insulation PVC Jacket Electrical Building Wire

2.5mm Cooper PVC Insulation PVC Jacket Electrical Building Wire

50mm2

Insulated

Solid

Heating

Copper

PVC

PVC

Round Wire

LSOH

ISO9001, CE

Jytop

Max. DC Resistance @ 20 Degree 7.41 Ohm/Km

Max. DC Resistance @ 20 Degree 4.61 Ohm/Km

Max. DC Resistance @ 20 Degree 3.08 Ohm/Km

BS, CSA, DIN, IEC…

JYTOP

100m/Rolls

1.5~185mm2

Zhengzhou, China

8544492100

Product Description

UL/cUL Electrical Wire PVC Hook up Wire Electrical Wiring Electric Wire

1. Flexible copper conductor
2. PVC insulation

Construction:
PVC insulated wires belong to the series of laying electric wires, which is mainly suitable for laying at the fixed places, it is widely used as connectors of drive, lighting, electric equipments, instrument and telecommunication equipments with rated coltage 450/750V or below, part of the plastic wires are used at the equipment with AC rated voltage 300/300v or below.

Standards:
The products adopt GB5023.1~7-1997 (450/750V or below PVC insulated electric wires), JB 8734.1~5-1998 (450/750V or under PVC insulated cables, electric wires and flexible wires) and Q/ZEL 02-2002 ( piastic insulated electric wires and cables ) GB 5023.1~7-1997is identical to IEC227, and type aresame as the stipulation of IEC, technical specification is just the same, and more we have extended the range of type to fit for the requirement of consumers.JB8734.1~5-1998 and Q/ZEL 02-2002 is the complementary content of GB 5023.1~7-1997, and Q/ZEL 02-2002 is stipulated to meet the requirment of consumers.

Range of our products :
1. 227IEC01/05 standard .BV/BLV type, copper conductor PVC insulated wires / aluminum conductor PVC insulated wires , fized laid indoors , conduits etc, long term working temperature 70 selsius degree.
2. 227IEC07 Standard, BV-90 type, heat resistant copper conductor PVC insulated wires at 90 selsius degree,mainly be laid at the places of high temperature environment and cab be laid indoors ,conduits.
BVR type , copper conductor PVC insulated flexible wire , be for laying pemanent place where flexible required, long term working temperature 70 selsius degree.
3. 227IEC10 standard, BW type, copper conductor PVC insulated PVC sheathed round wires,
BLW type, aluminum conductor PVC insulated PVC sheathed round wires,
BWB type, Copper conductor PVC insulated PVC sheathed flat wires.
BLWB type, aluminum conductor PVC insulated sheathed flat wires,
The above , mainly be fixed lain, fit for the places with high mechanical protection and moisture place, can be laid in the aire or underground, long term working temperature 70 selsius degree.
4. 227 IEC02RV / 227IEC06RV standard, copper conductor PVC insulated flexible connector,
227IEC42 RVB , copper conductor PVC insulated flat flexible connector .
RVS , copper conductor PVC insulated flexible twisting connector wire.
227IEC 52 RW, 227 IEC 53 RW ,standard, copper conductor PVC insulated PVC sheathed round flexible connector (light and common type ) , mainly used at middle and light style moving electronics, home applicances, power and lighting and the places where flexible required, long term working temperature 70 selsius degree.

227 IEC 05 BV wire :

Nominal sectional area ,mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
0.5 1/0.80 0.6 2.4 36.0 0.015 8.1
0.75 1/0.97 0.6 2.6 24.5 0.012 10.6
1 1/1.13 0.6 2.8 18.1 0.011 13.2

227 IEC 01 BV/BLV type PVC insulated wire :

Nominal sectional area mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
Cu Al Cu Al
1.5 1/1.38 0.7 3.3 12.1 0.011 19.2
1.5 7/0.52 0.7 3.5 12.1 0.010 20.6
2.5 1/1.78 0.8 3.9 7.41 11.8 0.010 30.8 15.0
4 1/2.25 0.8 4.4 4.61 7.39 0.0085 45.5 21.0
6 1/2.76 0.8 4.9 3.08 4.91 0.0070 65.0 29.0
10 7/1.35 1.0 7.0 1.83 3.08 0.0065. 110.0 52.0
16 7/1.70 1.0 8.0 1.15 1.91 0.0050 170.0 70.0
25 7/2.14 1.2 10.0 0.727 1.20 0.0050 270.0 110.0
35 7/2.52 1.2 11.5 0.524 0.868 0.0040 364.0 150.0
50 19/1.78 1.4 13.0 0.387 0.641 0.0045 500.0 200.0
70 19/2014 1.4 15.0 0.268 0.443 0.0035 688.0 269.0
95 19/2.52 1.6 17.5 0.193 0.320 0.0035 953.0 360.0
120 37/2.03 1.6 19.0 0.153 0.253 0.0032 1168.0 449.0
150 37/2.25 1.8 21.0 0.124 0.206 0.0032 1466.0 551.0
185 37/2.52 2.0 32.5 0.099 0.164 0.0032 1808.0 668.0

Type BVR 450/750V copper conductor PVC insulated flexible wire:

Nominal sectional area mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
2.5 9/0.41 0.8 4.2 7.41 0.011 33.0
4 19/0.52 0.8 4.8 4.61 0.009 48.0
6 19/0.64 0.8 5.6 3.08 0.0084 68.0
10 49/0.52 1.0 7.6 1.83 0.0072 115.0
16 49/0.64 1.0 8.8 1.15 0.0062 176.0
25 98/0.58 1.2 11.0 0.727 0.0058 272.0
35 133/0.58 1.2 12.5 0.524 0.0052 384.0
50 133/0.68 1.4 16.5 0.387 0.0051 510.0
70 189/0.68 1.4 16.5 0.268 0.0045 714.0
95 259/0.68 1.6 19.5 0.139 0.0035 965.0
120 259/0.76 1.8 22.0 0.153 0.0032 1210.0
150 259/0.85 1.8 25.0 0.124 0.0032 1510.0