18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) – Cables

Overhead Covers Conductors Thick

Overhead

XLPE

Crosslinking

Round Wire

CCC

SGS

Hongda

12/20kv, 18/30kv

En 50397-1

HDPE Compound

Hongda Cable

Steel & Wooden Drum

1.6*1.1

Made in China

8544601200

Product Description

18/30 kv Medium Voltage Overhead Covers Conductors Thick (CCT) – Cables

Application: Overhead single core cables with aluminum alloy conductor and XLPE insulation, for overhead power transmission and distribution lines up to 20 K & 33 KV.
The Covered Conductor Thick (CCT) system, although not a touch-safe screened cable system, is designed to provide protection from initiation of flash-overs due to clashing of conductors, bird or animal incursions, and tree branches or debris which has blown or fallen on to the line , specially in Weather conditions pollution.

ENGINEERING SPECIFICATIONS

Standard EN 50397-1
Rated Voltage 12/20 or 18/30 kv
Conductor stranded aluminum alloy wire(AAAC) or ACSR.
Core the conductor is insulated with a layer of extruded XLPE .
Sheath over the insulated core is applied an outer protecting layer of extruded HDPE compound.
Operating temperature 90°c continues normal operation.

Overhead Covers Conductors STRUCTURE:

Technical Specification according to EN 50397 CCT:

Description of property Unit of measurement Amounts/Specifications
All Aluminum Alloy Conductors (AAAC) Aluminum conductor steel reinforced (ACSR)
Size mm2 70 120 185 MINK HYENA WOLF
Conductor Construction N x mm 7×3.75 19×2.95 19×3.50 ST 1×3.66
AL 6×3.66
ST 7×1.93
AL 7×4.39
ST 7×2.59
AL 30×2.59
Cross Section mm2 77.3 129.9 182.8 73.6 126.4 194.9
Conductor diameter (compacted) mm 10.69 14.01 16.63 10.21 13.55 16.86
Covering type XLPE / Black HDPE
Tensile Strength KN 21.67 36.39 51.23 20.59 38.86 65.46
Electrical Resistance at 20ºC Ohm/km 0.4467 0.2674 0.1900 0.4767 0.2843 0.1920
Rated voltage kV 20 33 20 33 20 33 20 33 20 33 20 33
Covering Thickness
(two Layers)
Min mm 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0
Max mm 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1
Min at place mm 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10
HDPE Thickness Min mm 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6
Max mm 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2
Overall Diameter Min mm 21.6 26.6 24.8 29.8 27.5 32.5 21.1 26.1 24.5 29.5 27.8 32.8
Max mm 23.2 29.0 26.4 32.2 29.1 34.9 22.7 28.5 26.1 31.9 29.4 35.2
Mass per Unit Length Kg/km 484 672 682 895 867 1100 514 698 758 967 1076 1311

Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and 2 days collection as standard.

Any problem and inquiry pls contact with Vivian Yuan.
Phone number: +86-18339931106

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.