15kv Aerial Bundle Cable

15kv Aerial Bundle Cable

15kv Aerial Bundle Cable

Overhead, Power Station

Low and Medium Voltage Cable

DC & AC

XLPE

XLPE

Round Wire

Aluminum

ISO, CCC, CE

Sac

Yifang

Yifang

Steel Wooden Drum

1.1, 2.2

Henan, China

8544601200

Product Description

15kv Aluminum SAC Cable Service Drop Cable

1. Application of Service Drop Cable: 
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 

2. Type of Service Drop Cable: 
Service Drop Cable(ABC CABLE) covers mainly three types: 
Duplex Service Drop 

Triplex Service Drop 
Quadruplex service drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 

3. Detaild Introduction of Service Drop Cable 

3.1 Duplex Service Drop 

Applications 
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.2 Triplex Service Drop 

Applications 
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.3 Quadruplex Service Drop 

Applications 
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. 

Construction 
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated and Sheath with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.