Product Description
Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.
Construction
Conductors are concentric strand AAC (1350-H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TR-HDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (TK-XLPE) covering per ASTM D2656 and ICEA S-66-524. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance.
NOTES:
Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with HONGDA CABLE for more information.
Item # | Size (AWG or kcmil) |
Stranding | Conductor Diameter (mils) |
Covering Thickness Conductor Shield (mils) |
Covering Thickness Inner Layer (mils) |
Covering Thickness Outer Layer (mils) |
Cable O.D. (mils) |
Rated Strength (lbs) |
Weight (lb/MFT) |
---|---|---|---|---|---|---|---|---|---|
TW35-3-ACSR-1/0-6/1 | 1/0 | 6/1 | 398 | 15 | 175 | 125 | 1028 | 4161 | 448 |
TW35-3-ACSR-2/0-6/1 | 2/0 | 6/1 | 447 | 15 | 175 | 125 | 1077 | 5045 | 509 |
TW35-3-ACSR-4/0-6/1 | 4/0 | 6/1 | 563 | 15 | 175 | 125 | 1193 | 7933 | 673 |
TW35-3-ACSR-266.8-18/1 | 266.8 | 18/1 | 609 | 15 | 175 | 125 | 1239 | 6536 | 684 |
TW35-3-ACSR-266.8-26/7 | 266.8 | 26/7 | 642 | 15 | 175 | 125 | 1272 | 10735 | 770 |
TW35-3-ACSR-336.4-18/1 | 336.4 | 18/1 | 684 | 15 | 175 | 125 | 1314 | 8246 | 794 |
TW35-3-ACSR-336.4-26/7 | 336.4 | 26/7 | 720 | 15 | 175 | 125 | 1350 | 13395 | 901 |
TW35-3-ACSR-336.4-30/7 | 336.4 | 30/7 | 741 | 15 | 175 | 125 | 1371 | 16435 | 1170 |
TW35-3-ACSR-397.5-18/1 | 397.5 | 18/1 | 743 | 15 | 175 | 125 | 1373 | 9443 | 889 |
TW35-3-ACSR-397.5-24/7 | 397.5 | 24/7 | 772 | 15 | 175 | 125 | 1402 | 13870 | 949 |
TW35-3-ACSR-397.5-26/7 | 397.5 | 26/7 | 783 | 15 | 175 | 125 | 1413 | 15485 | 1013 |
TW35-3-ACSR-477-24/7 | 477 | 24/7 | 846 | 20 | 175 | 125 | 1486 | 16340 | 1091 |
TW35-3-ACSR-477-26/7 | 477 | 26/7 | 858 | 20 | 175 | 125 | 1498 | 18525 | 1168 |
TW35-3-ACSR-477-30/7 | 477 | 30/7 | 883 | 20 | 175 | 125 | 1523 | 22610 | 1552 |
TW35-3-ACSR-556.5-18/1 | 556.5 | 18/1 | 879 | 20 | 175 | 125 | 1519 | 13015 | 1138 |
TW35-3-ACSR-556.5-24/7 | 556.5 | 24/7 | 914 | 20 | 175 | 125 | 1554 | 18810 | 1220 |
TW35-3-ACSR-556.5-26/7 | 556.5 | 26/7 | 927 | 20 | 175 | 125 | 1567 | 21470 | 1309 |
TW35-3-ACSR-636-18/1 | 636 | 18/1 | 940 | 20 | 175 | 125 | 1580 | 14915 | 1637 |
TW35-3-ACSR-636-26/7 | 636 | 26/7 | 990 | 20 | 175 | 125 | 1630 | 23940 | 1826 |
TW35-3-ACSR-795-26/7 | 795 | 26/7 | 1107 | 20 | 175 | 125 | 1747 | 29925 | 2146 |
TW35-3-ACSR-795-45/7 | 795 | 45/7 | 1063 | 20 | 175 | 125 | 1703 | 20995 | 1892 |