(12 / 20) 24kv Overhead Insulated Cable 3X95/16mm2
(12 / 20) 24kv Overhead Insulated Cable 3X95/16mm2
( 12 / 20 ) 24kv overhead insulated cable 3×95/16m
Insulated
Stranded
Overhead
Aluminum
Crosslinking
XLPE
Round Wire
Overhead
ISO9001, CE, UL, CCC
Yifang
Yifang
Drums
1000meter per drum
China
8544601200
Product Description
( 12 / 20 ) 24kv overhead insulated cable 3×95/16mm2
Aerial Bundled Conductor Cables Application
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.
Aerial Bundled Conductor Cables Standard
Basic design to IEC 60502 / AS/NZS 3599-1 standards
Aerial Bundled Conductor Cables Construction
Phase Conductor | Circular compacted stranded H68 aluminium to BS2627. |
Conductor Screen | Extruded semi-conductive layer. |
Insulation | XLPE. |
Insulation Screen | Extruded semi-conductive layer. |
metallic Screen(optional) | Copper wire screen or copper tape screen. |
Separator | Semi-conductive swellable tape. |
Outer Sheath | HDPE. |
Support Conductor | Galvanized steel wires. |
Assembly | Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay. |
Aerial Bundled Conductor Cables Construction Parameters
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines
Number of Cores x Nominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 300C ambient temp | ||||
---|---|---|---|---|---|---|---|
Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
No.×mm^2 | No.×mm | mm^2 | Ω/Km | No.×mm | mm^2 | KN | A |
3X50 + 1X25 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 116 |
3X70 + 1X50 | 19/.14 | 70 | 0.443 | 7/3.15 | 50 | 62 | 210 |
3X95+ 1X50 | 19/2.52 | 95 | 0.32 | 7/3.0 | 50 | 60 | 173 |
3X185+1X120 | 37/2.52 | 185 | 0.164 | 7/4.67 | 120 | 150 | 259 |
3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 365 |
3X240 +1X50 | 61/2.25 | 240 | 0.125 | 7/3.15 | 50 | 62 | 500 |
Other ( 12 / 20 ) 24kv overhead insulated cable 3×95/16mm2 cross-sections can be offered upon request.
IEC 60502 19/33 kV ABC for Overhead Distribution Lines
Number of Cores x Nominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 300C ambient temp | ||||
---|---|---|---|---|---|---|---|
Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
No.×mm^2 | No.×mm | mm^2 | Ω/Km | No.×mm | mm^2 | KN | A |
3X50 + 1X50 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 165 |
3X150+ 1X50 | 37/2.25 | 150 | 0.206 | 7/3.0 | 50 | 60 | 315 |
3X185+1X70 | 37/2.52 | 185 | 0.164 | 7/3.57 | 70 | 91 | 355 |
3X70 +1X50 | 19/2.14 | 7 | 0.443 | 7/3.15 | 50 | 62 | 250 |
3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 370 |