0.6/1kv Shielded/Screened Control Cable Multiconductor Cable with Aluminum

0.6/1kv Shielded/Screened Control Cable Multiconductor Cable with Aluminum

0.6/1kv Shielded/Screened Control Cable Multiconductor Cable with Aluminum

kvvp

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

AC Cable

PVC

PVC

Round Wire

Bare Copper Wire

ISO

KVVP

Jytop

Control Cable

450/750V

6 Cores 0.5-630mm2

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Ce, ISO 9001

JYTOP

Packed in 500m Coils or in Wooden Reels

any Third party Pre-shipment inspection

Zhengzhou, China

8544492100

Product Description

0.6/1kv Shielded/Screened Control Cable multiconductor cable with aluminum
Application
Control Cable is suitable for cable channel, laying in indoors,and conduit etc., such cables can’t bear strong mechanical force. PVC sheath not only has excellent chemical corrosion resistance, but also has the properties of flame retardant and non water-absorption.

Feature
1. Nakamichi Soundspace 8 Control Cable
2. XLPE Insulated and Jacket Power Cable
3. CCC Certification
 
Parameter
1. Ratedal temperature of conductor is 20°C
2. AC Voltage test
3. The test should be carried out on the complete drum of cable.When the environmental temperature is 20±15°C,apply AC 3.5KV for 5 minutes.The insulation should not break drown during test.
 
Specification
Type: KVV, KVVP
Rated Voltages: 450/750v
Specification: 6 Cores 0.5-630mm2
Length: 300M 500M 1000M

.Type& Specification

Type Name Section Area(mm2) No. of Core Application Site
KVV Copper Conductor,PVC Insulated and Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KVVP Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KVVP2 Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KVV22 Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force
4 6 4-14
10 4-14
KVVR Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KVVRP Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable 0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5 2.5 4-48
KYJV Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
 
KYJV22
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force
4 6 4-14
10 4-10
KYJVP2 Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 4-14
10 4-10
KYJVR Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KYJVRP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable 0.5 0.75 1.0 4-61  
    1.5 2.5 4-48 Installation indoors where flexibility shielding and movability are required

If you have any questions on electrics / cable wires , please feel free to contact us.

web 1: jytopcable    
web 2: electriccable.cc      
web 3: abccable,net

Tags: , ,