0.6/1kv PVC Insulation PVC Sheath Nyy Power Cable

0.6/1kv PVC Insulation PVC Sheath Nyy Power Cable

0.6/1kv PVC Insulation PVC Sheath Nyy Power Cable

Rmjt

ISO9001, CCC

LSOH

Round Wire

XLPE

Crosslinking

Copper

Underground

Stranded

Insulated

0.6-35kv

1*3 1*7 1*19 1*37

Yes

Power Transimision

RMJT

Wooden Drum

BS GB IEC

China

8544492100

Product Description

0.6/1KV 3*35mm2 PVC insulation PVC sheath NYY cable 

1.Application
NYY power cable is used to transmit and distribute power for the power transmission and distribution system of 35kV or lower. It is generally applied in the fields of power, construction, mine, metallurgy, petrochemical industry and communication. It completely replaces the oil immersed paper insulated power cable and partiallyreplaces the PVC insulated power cable.

2.Standard:
 BS EN  IEC , etc..

3.Specification
 

Type Description Application Occasion
Cu Al
VV VLV PVC insulation PVC sheath power cable ,,..
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldnt bear mechanical force outside 
VV22 VLV22 PVC insulation, steel tape armor,  PVC sheath power cable ,,,.
To be laid underground, the cable could bear certain mechanical force,
VV62 VV62 PVC insulation, have no the magnetism steel tape armor,  PVC sheath power cable.
VV32 VLV32 PVC insulation, thin steel-wire  armor,  PVC sheath power cable ,,.
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
VV72 VLV72 PVC insulation, have no the magnetism thick steel-wire  armor,  PVC sheath power cable
VV42 VLV42 PVC insulation, thick steel-wire  armor,  PVC sheath power cable

Hint specially

1,6272.
The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable.
2,.
Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability.

Rated Voltage, No. of Core and Range of Sectional Area

Cross No 1 2 3 3+1 4 3+2 4+1 5
Area 4~500 2.5~500 2.5~300 4~300 2.5~300 2.5~300 4~300 2.5~95

4. DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.

Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367

5.Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.

6.Customer Visit  
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!

7.Production process:
AAC conductor producing process is drawing stranding and cabling,our factory possess 2 subsidiaries,Zhulin factory is professional bare conductor workshop with 20 production line.

8.Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.

9.About us:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. 

Tags: , ,