0.6/1kv PVC Insulated Power Cable VV Vlv VV22 VV32 VV42 Power Cable 1.5mm 2.5mm 4mm 6mm 10mm
Product Description
Application range
Power and control cable for fixed installation in the following applications:
For indoor and outdoor use
Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 – Part 3-G (point 4)
governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD
603/VDE 0276-603 – Part 3-G (point 4) governing PVC cables for direct burial
In water: no longer than 2 weeks at a time, maximum submersion depth 10 metres, only in static water/bodies of water without
shipping traffic
Product Make-up
Aluminium conductor
Abbreviations "re", "rm", "se", "sm": r = round conductor form; s = sectorial conductor form; e = single-wire conductor (wire =
conductor)/braided conductor class 1 according to IEC 60228/VDE 0295 for fixed, static applications; m = multi-wire
conductor/braided conductor class 2 according to IEC 60228/VDE 0295 for fixed, static applications, but with a slightly lower
minimum bending factor
Core insulation: Based on PVC
Filling compound over the core assembly
PVC-based outer sheath
Norm references / Approvals
HD 603/VDE 0276-603
Product features
Flame-retardant according IEC 60332-1-2
Maximum tensile strain for aluminium conductors during installation is 30 N/mm² according to HD 603/VDE 0276-603: Part 1
Appendix A.4.12 and Part 3-G point 4
Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD
603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C
according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration
corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the
catalogue appendix T12) for installation in and on buildings
Technical Data
Core identification code: According to VDE 0293-308 (table T9)
Classification: ETIM 5.0 Class-ID: EC000057
ETIM 5.0 Class-Description: Low voltage power cable
Conductor stranding: Single-wire
Minimum bending radius: Fixed installation: 12 x outer diameter
Nominal voltage: Uo/U: 0.6/1.0 kV
Test voltage: 4000 V
Temperature range: During installation: -5°C to +50°C
Fixed installation: -30°C to +70°C
Number of cores and mm² per conductor |
Outer diameter (mm) | Alu index (kg/km) | Weight (kg/km) |
4*35re | 29 | 406 | 1170 |
4*50se | 30 | 580 | 1305 |
4*70se | 35 | 812 | 1730 |
4*95se | 9 | 1102 | 2205 |
4*120se | 2 | 1392 | 2655 |
4*150se | 46 | 1740 | 3150 |
4*185se | 51 | 2146 | 3925 |
4*240se | 60 | 2784 | 4880 |
- Next: Triplex Service Drop Aluminum Conductors AAAC Neutral-Messenger Cable
- Previous: New Type All Aluminum Conductor (AAC)
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
Low Voltage Single Core Power Cable 1X300 mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV
-