0.6/1kv Power Cable Al/XLPE/Swa/PVC
0.6/1kv Power Cable Al/XLPE/Swa/PVC
POWER CABLE
Jinyuan
ISO9001, CE, UL, CCC, RoHS, VDE
Mine
Round Wire
XLPE
PVC
Aluminum
Underground
Stranded
Insulated
1km
as Requirement
Jinyuan
Drum
3x90mm²
China
8544601200
Product Description
0.6/1kV XLPE Insulated Unarmored Power Cable
YJV CU/XLPE/PVC
ZR-YJV CU/XLPE/FR-PVC
Standards
International: IEC 60502, IEC 60228, (IEC 60332-3 for ZR-YJV only)
China: GB/T 12706, (GB/T 18380-3 for ZR-YJV only)
Other standards such as BS, DIN and ICEA upon request
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Insulation : XLPE(cross-linked polyethylene) rated at 90ºC
Sheath : PVC or FR-PVC type ST2 to IEC 60502, black
Applications
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.
Technical data
Rated voltage: 0.6 / 1 kV
Maximum Conductor Temperature: under normal (90ºC), emergency (130ºC) or short circuit no more than 5 s (250ºC) conditions.
Min. Ambient Temp. 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core
15 x cable O.D for multi core
YJV CU/XLPE/PVC
ZR-YJV CU/XLPE/FR-PVC
Standards
International: IEC 60502, IEC 60228, (IEC 60332-3 for ZR-YJV only)
China: GB/T 12706, (GB/T 18380-3 for ZR-YJV only)
Other standards such as BS, DIN and ICEA upon request
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Insulation : XLPE(cross-linked polyethylene) rated at 90ºC
Sheath : PVC or FR-PVC type ST2 to IEC 60502, black
Applications
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.
Technical data
Rated voltage: 0.6 / 1 kV
Maximum Conductor Temperature: under normal (90ºC), emergency (130ºC) or short circuit no more than 5 s (250ºC) conditions.
Min. Ambient Temp. 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core
15 x cable O.D for multi core
Specification
Specification (mm²) | Insulation thickness(mm) | Sheath thickness(mm) | O.D (mm) |
Reference weight of cable(kg/km) | Max D.C resistance at 20°c(Ω/km) | Recommended Current Capacity(A) | |||
Cu | Al | Cu | Al | Cu | Al | ||||
4*4+1*2.5 | 0.7 | 1.5 | 14.5 | 331 | 214 | 4.61 | 7.41 | 34 | 27 |
4*6+1*4 | 0.7 | 1.5 | 15.9 | 435 | 259 | 3.08 | 4.61 | 43 | 35 |
4*10+1*6 | 0.7 | 1.5 | 18.9 | 649 | 359 | 1.83 | 3.08 | 60 | 47 |
4*16+1*10 | 0.7 | 1.5 | 21.9 | 965 | 499 | 1.15 | 1.91 | 83 | 64 |
4*25+1*16 | 0.9 | 2 | 26.2 | 1456 | 725 | 0.727 | 1.2 | 105 | 82 |
4*35+1*16 | 0.9 | 2 | 28.8 | 1863 | 882 | 0.524 | 0.868 | 125 | 100 |
4*50+1*25 | 1 | 2 | 33.4 | 2633 | 1216 | 0.387 | 0.641 | 160 | 125 |
4*70+1*35 | 1.1 | 2 | 38.8 | 3565 | 1581 | 0.268 | 0.443 | 200 | 155 |
4*95+1*50 | 1.1 | 2 | 44.1 | 4735 | 2028 | 0.193 | 0.32 | 245 | 200 |
4*120+1*70 | 1.2 | 2.5 | 49.5 | 5977 | 2512 | 0.153 | 0.253 | 285 | 220 |
4*150+1*70 | 1.4 | 2.5 | 54.1 | 7276 | 3055 | 0.124 | 0.206 | 325 | 250 |
4*185+1*95 | 1.6 | 3 | 60.5 | 9055 | 3797 | 0.0991 | 0.164 | 375 | 295 |
4*240+1*120 | 1.7 | 3 | 68.2 | 11567 | 4763 | 0.0754 | 0.125 | 440 | 345 |
- Next: ACSR, DIN Standard, 95/15mm2 ACSR Conductor
- Previous: ASTM A741 Standard Zinc Coated Galvanized Steel Wire Rope