0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv

0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv

0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv

CVV

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

PVC

PVC

Round Wire

Bare Copper Wire

ISO, CCC

Cvv

Hongda

Hongda

Wooden Drum

2-30 cores, 0.5-6mm2

China

8544492100

Product Description

Application
For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

Standards
IEC 60502, IEC 60228

Products Type

Type Descriptions Applications
CVV Copper conductor PVC insulated PVC sheathed control cables For laying indoor, in tunnels, ducts,
conduit etc.permanent place

NOTE: Henan Hongda can produce "Flame-Retardant Series", "Fire-Resistant Series", "Low Smoke Halogen Free (LSHF/LSOH) Series","Low Smoke Low Halogen (LSLH) Series", etc. control cable as customer required.
Performance in line with IEC60332: 2004 requirements.

Construction
Conductor: Concentric Stranded copper wire
Insulation: PVC Black color
Identification : Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath : PVC Black color

2 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
2 0.5 7/0.30 0.8 1.8 10.0 36.0 0.0162 98 500/D
0.75 7/0.37 0.8 1.8 10.0 24.5 0.0142 110 500/D
1 7/0.40 0.8 1.8 10.5 18.1 0.0135 115 500/D
1.5 7/0.50 0.8 1.8 11.0 12.1 0.0115 135 500/D
2.5 7/0.67 0.8 1.8 12.0 7.41 0.0093 180 500/D
4 7/0.85 1.0 1.8 14.5 4.61 0.0092 255 500/D
6 7/1.04 1.0 1.8 15.5 3.08 0.0078 320 500/D

3 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
3 0.5 7/0.30 0.8 1.8 10.0 36.0 0.0162 110 500/D
0.75 7/0.37 0.8 1.8 10.5 24.5 0.0142 125 500/D
1 7/0.40 0.8 1.8 11.0 18.1 0.0135 135 500/D
1.5 7/0.50 0.8 1.8 11.5 12.1 0.0115 160 500/D
2.5 7/0.67 0.8 1.8 13.0 7.41 0.0093 220 500/D
4 7/0.85 1.0 1.8 15.0 4.61 0.0092 315 500/D
6 7/1.04 1.0 1.8 16.5 3.08 0.0078 405 500/D

4 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
4 0.5 7/0.30 0.8 1.8 11.0 36.0 0.0162 130 500/D
0.75 7/0.37 0.8 1.8 11.5 24.5 0.0142 150 500/D
1 7/0.40 0.8 1.8 11.5 18.1 0.0135 160 500/D
1.5 7/0.50 0.8 1.8 12.5 12.1 0.0115 195 500/D
2.5 7/0.67 0.8 1.8 14.0 7.41 0.0093 265 500/D
4 7/0.85 1.0 1.8 16.5 4.61 0.0092 390 500/D
6 7/1.04 1.0 1.8 17.0 3.08 0.0078 510 500/D

5 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
5 0.5 7/0.30 0.8 1.8 11.5 36.0 0.0162 150 500/D
0.75 7/0.37 0.8 1.8 12.5 24.5 0.0142 175 500/D
1 7/0.40 0.8 1.8 12.5 18.1 0.0135 190 500/D
1.5 7/0.50 0.8 1.8 13.5 12.1 0.0115 230 500/D
2.5 7/0.67 0.8 1.8 15.0 7.41 0.0093 320 500/D
4 7/0.85 1.0 1.8 18.0 4.61 0.0092 470 500/D
6 7/1.04 1.0 1.8 19.5 3.08 0.0078 620 500/D

6 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
6 0.5 7/0.30 0.8 1.8 12.5 36.0 0.0162 165 500/D
0.75 7/0.37 0.8 1.8 13.0 24.5 0.0142 190 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 205 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 255 500/D
2.5 7/0.67 0.8 1.8 16.0 7.41 0.0093 355 500/D
4 7/0.85 1.0 1.8 19.5 4.61 0.0092 525 500/D
6 7/1.04 1.0 1.8 21.0 3.08 0.0078 690 500/D

7 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
7 0.5 7/0.30 0.8 1.8 12.5 36.0 0.0162 170 500/D
0.75 7/0.37 0.8 1.8 13.0 24.5 0.0142 200 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 215 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 270 500/D
2.5 7/0.67 0.8 1.8 16.0 7.41 0.0093 380 500/D
4 7/0.85 1.0 1.8 19.5 4.61 0.0092 570 500/D
6 7/1.04 1.0 1.8 21.0 3.08 0.0078 795 500/D

8 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
8 0.5 7/0.30 0.8 1.8 13.5 36.0 0.0162 195 500/D
0.75 7/0.37 0.8 1.8 14.0 24.5 0.0142 230 500/D
1 7/0.40 0.8 1.8 14.5 18.1 0.0135 250 500/D
1.5 7/0.50 0.8 1.8 15.5 12.1 0.0115 310 500/D
2.5 7/0.67 0.8 1.8 17.5 7.41 0.0093 440 500/D
4 7/0.85 1.0 1.8 21.0 4.61 0.0092 660 500/D
6 7/1.04 1.0 1.8 23.0 3.08 0.0078 875 500/D

9 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
9 0.5 7/0.30 0.8 1.8 14.0 36.0 0.0162 220 500/D
0.75 7/0.37 0.8 1.8 15.0 24.5 0.0142 265 500/D
1 7/0.40 0.8 1.8 15.5 18.1 0.0135 285 500/D
1.5 7/0.50 0.8 1.8 16.5 12.1 0.0115 355 500/D
2.5 7/0.67 0.8 1.8 18.5 7.41 0.0093 505 500/D
4 7/0.85 1.0 1.8 22.5 4.61 0.0092 760 500/D
6 7/1.04 1.0 1.8 24.5 3.08 0.0078 1015 500/D

10 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
10 0.5 7/0.30 0.8 1.8 15.5 36.0 0.0162 240 500/D
0.75 7/0.37 0.8 1.8 16.0 24.5 0.0142 285 500/D
1 7/0.40 0.8 1.8 16.5 18.1 0.0135 310 500/D
1.5 7/0.50 0.8 1.8 18.0 12.1 0.0115 385 500/D
2.5 7/0.67 0.8 1.8 20.0 7.41 0.0093 550 500/D
4 7/0.85 1.0 1.8 24.5 4.61 0.0092 825 500/D
6 7/1.04 1.0 1.8 27.0 3.08 0.0078 1100 500/D

11 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
11 0.5 7/0.30 0.8 1.8 15.5 36.0 0.0162 255 500/D
0.75 7/0.37 0.8 1.8 16.5 24.5 0.0142 315 500/D
1 7/0.40 0.8 1.8 17.0 18.1 0.0135 340 500/D
1.5 7/0.50 0.8 1.8 18.5 12.1 0.0115 425 500/D
2.5 7/0.67 0.8 1.8 21.0 7.41 0.0093 605 500/D
4 7/0.85 1.0 1.8 25.0 4.61 0.0092 915 500/D
6 7/1.04 1.0 1.8 27.5 3.08 0.0078 1220 500/D

12 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
12 0.5 7/0.30 0.8 1.8 15.5 36.0 0.0162 265 500/D
0.75 7/0.37 0.8 1.8 16.5 24.5 0.0142 320 500/D
1 7/0.40 0.8 1.8 17.0 18.1 0.0135 345 500/D
1.5 7/0.50 0.8 1.8 18.5 12.1 0.0115 440 500/D
2.5 7/0.67 0.8 1.8 21.0 7.41 0.0093 630 500/D
4 7/0.85 1.0 1.8 25.0 4.61 0.0092 950 500/D
6 7/1.04 1.0 1.8 27.5 3.08 0.0078 1270 500/D

13 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
13 0.5 7/0.30 0.8 1.8 16.5 36.0 0.0162 295 500/D
0.75 7/0.37 0.8 1.8 17.5 24.5 0.0142 355 500/D
1 7/0.40 0.8 1.8 18.0 18.1 0.0135 380 500/D
1.5 7/0.50 0.8 1.8 19.5 12.1 0.0115 485 500/D
2.5 7/0.67 0.8 1.8 22.0 7.41 0.0093 695 500/D
4 7/0.85 1.0 1.8 26.5 4.61 0.0092 1050 500/D
6 7/1.04 1.0 1.8 29.0 3.08 0.0078 1405 500/D

14 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
14 0.5 7/0.30 0.8 1.8 16.5 36.0 0.0162 300 500/D
0.75 7/0.37 0.8 1.8 17.5 24.5 0.0142 360 500/D
1 7/0.40 0.8 1.8 18.0 18.1 0.0135 390 500/D
1.5 7/0.50 0.8 1.8 19.5 12.1 0.0115 495 500/D
2.5 7/0.67 0.8 1.8 22.0 7.41 0.0093 715 500/D
4 7/0.85 1.0 1.8 26.5 4.61 0.0092 1085 500/D
6 7/1.04 1.0 1.8 29.0 3.08 0.0078 1455 500/D

15 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
15 0.5 7/0.30 0.8 1.8 17.0 36.0 0.0162 330 500/D
0.75 7/0.37 0.8 1.8 18.5 24.5 0.0142 395 500/D
1 7/0.40 0.8 1.8 19.0 18.1 0.0135 425 500/D
1.5 7/0.50 0.8 1.8 20.5 12.1 0.0115 545 500/D
2.5 7/0.67 0.8 1.8 23.0 7.41 0.0093 785 500/D
4 7/0.85 1.0 1.8 28.0 4.61 0.0092 1195 500/D
6 7/1.04 1.0 1.8 31.0 3.08 0.0078 1600 500/D

16 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
16 0.5 7/0.30 0.8 1.8 17.0 36.0 0.0162 330 500/D
0.75 7/0.37 0.8 1.8 18.5 24.5 0.0142 400 500/D
1 7/0.40 0.8 1.8 19.0 18.1 0.0135 435 500/D
1.5 7/0.50 0.8 1.8 20.5 12.1 0.0115 555 500/D
2.5 7/0.67 0.8 1.8 23.0 7.41 0.0093 805 500/D
4 7/0.85 1.0 1.8 28.0 4.61 0.0092 1230 500/D
6 7/1.04 1.0 1.8 31.0 3.08 0.0078 1650 500/D

17 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
17 0.5 7/0.30 0.8 1.8 18.0 36.0 0.0162 355 500/D
0.75 7/0.37 0.8 1.8 19.0 24.5 0.0142 430 500/D
1 7/0.40 0.8 1.8 19.5 18.1 0.0135 465 500/D
1.5 7/0.50 0.8 1.8 21.5 12.1 0.0115 595 500/D
2.5 7/0.67 0.8 1.8 24.0 7.41 0.0093 865 500/D
4 7/0.85 1.0 1.8 29.5 4.61 0.0092 1315 500/D
6 7/1.04 1.0 1.9 32.5 3.08 0.0078 1785 500/D

18 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
18 0.5 7/0.30 0.8 1.8 18.0 36.0 0.0162 360 500/D
0.75 7/0.37 0.8 1.8 19.0 24.5 0.0142 435 500/D
1 7/0.40 0.8 1.8 19.5 18.1 0.0135 475 500/D
1.5 7/0.50 0.8 1.8 21.5 12.1 0.0115 605 500/D
2.5 7/0.67 0.8 1.8 24.0 7.41 0.0093 885 500/D
4 7/0.85 1.0 1.8 29.5 4.61 0.0092 1350 500/D
6 7/1.04 1.0 1.9 32.5 3.08 0.0078 1835 500/D

19 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
19 0.5 7/0.30 0.8 1.8 18.0 36.0 0.0162 365 500/D
0.75 7/0.37 0.8 1.8 19.0 24.5 0.0142 445 500/D
1 7/0.40 0.8 1.8 19.5 18.1 0.0135 480 500/D
1.5 7/0.50 0.8 1.8 21.5 12.1 0.0115 620 500/D
2.5 7/0.67 0.8 1.8 24.0 7.41 0.0093 905 500/D
4 7/0.85 1.0 1.8 29.5 4.61 0.0092 1385 500/D
6 7/1.04 1.0 1.9 32.5 3.08 0.0078 1885 500/D

20 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
20 0.5 7/0.30 0.8 1.8 19.0 36.0 0.0162 390 500/D
0.75 7/0.37 0.8 1.8 20.0 24.5 0.0142 475 500/D
1 7/0.40 0.8 1.8 20.5 18.1 0.0135 515 500/D
1.5 7/0.50 0.8 1.8 22.5 12.1 0.0115 665 500/D
2.5 7/0.67 0.8 1.8 25.5 7.41 0.0093 975 500/D
4 7/0.85 1.0 1.8 31.0 4.61 0.0092 1490 500/D
6 7/1.04 1.0 2.0 34.5 3.08 0.0078 2040 500/D

21 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
21 0.5 7/0.30 0.8 1.8 19.0 36.0 0.0162 400 500/D
0.75 7/0.37 0.8 1.8 20.0 24.5 0.0142 490 500/D
1 7/0.40 0.8 1.8 20.5 18.1 0.0135 530 500/D
1.5 7/0.50 0.8 1.8 22.5 12.1 0.0115 685 500/D
2.5 7/0.67 0.8 1.8 25.5 7.41 0.0093 1005 500/D
4 7/0.85 1.0 1.8 31.0 4.61 0.0092 1540 500/D
6 7/1.04 1.0 2.0 34.5 3.08 0.0078 2040 500/D

22 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
22 0.5 7/0.30 0.8 1.8 20.0 36.0 0.0162 430 500/D
0.75 7/0.37 0.8 1.8 21.0 24.5 0.0142 520 500/D
1 7/0.40 0.8 1.8 21.5 18.1 0.0135 565 500/D
1.5 7/0.50 0.8 1.8 23.5 12.1 0.0115 730 500/D
2.5 7/0.67 0.8 1.8 265 7.41 0.0093 1070 500/D
4 7/0.85 1.0 1.9 32.5 4.61 0.0092 1655 500/D
6 7/1.04 1.0 2.0 36.5 3.08 0.0078 2245 500/D

23 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
23 0.5 7/0.30 0.8 1.8 19.5 36.0 0.0162 440 500/D
0.75 7/0.37 0.8 1.8 21.0 24.5 0.0142 540 500/D
1 7/0.40 0.8 1.8 21.5 18.1 0.0135 585 500/D
1.5 7/0.50 0.8 1.8 23.5 12.1 0.0115 755 500/D
2.5 7/0.67 0.8 1.8 26.5 7.41 0.0093 1105 500/D
4 7/0.85 1.0 1.9 32.5 4.61 0.0092 1710 500/D
6 7/1.04 1.0 2.0 36.5 3.08 0.0078 2330 500/D

24 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
24 0.5 7/0.30 0.8 1.8 21.0 36.0 0.0162 460 500/D
0.75 7/0.37 0.8 1.8 22.0 24.5 0.0142 560 500/D
1 7/0.40 0.8 1.8 23.0 18.1 0.0135 605 500/D
1.5 7/0.50 0.8 1.8 24.5 12.1 0.0115 785 500/D
2.5 7/0.67 0.8 1.8 28.0 7.41 0.0093 1150 500/D
4 7/0.85 1.0 2.0 34.5 4.61 0.0092 1795 500/D
6 7/1.04 1.0 2.0 36.5 3.08 0.0078 2330 500/D

25 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
25 0.5 7/0.30 0.8 1.8 21.0 36.0 0.0162 490 500/D
0.75 7/0.37 0.8 1.8 22.5 24.5 0.0142 595 500/D
1 7/0.40 0.8 1.8 23.0 18.1 0.0135 645 500/D
1.5 7/0.50 0.8 1.8 25.5 12.1 0.0115 835 500/D
2.5 7/0.67 0.8 1.8 28.5 7.41 0.0093 1225 500/D
4 7/0.85 1.0 2.0 35.5 4.61 0.0092 1915 500/D
6 7/1.04 1.0 2.1 39.5 3.08 0.0078 2595 500/D

26 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
27 0.5 7/0.30 0.8 1.8 21.0 36.0 0.0162 500 500/D
0.75 7/0.37 0.8 1.8 22.5 24.5 0.0142 610 500/D
1 7/0.40 0.8 1.8 23.0 18.1 0.0135 665 500/D
1.5 7/0.50 0.8 1.8 25.5 12.1 0.0115 860 500/D
2.5 7/0.67 0.8 1.8 28.5 7.41 0.0093 1270 500/D
4 7/0.85 1.0 2.0 35.5 4.61 0.0092 1985 500/D
6 7/1.04 1.0 2.1 39.5 3.08 0.0078 2700 500/D

27 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
27 0.5 7/0.30 0.8 1.8 21.0 36.0 0.0162 500 500/D
0.75 7/0.37 0.8 1.8 22.5 24.5 0.0142 610 500/D
1 7/0.40 0.8 1.8 23.0 18.1 0.0135 665 500/D
1.5 7/0.50 0.8 1.8 25.5 12.1 0.0115 860 500/D
2.5 7/0.67 0.8 1.8 28.5 7.41 0.0093 1270 500/D
4 7/0.85 1.0 2.0 35.5 4.61 0.0092 1985 500/D
6 7/1.04 1.0 2.1 39.5 3.08 0.0078 2700 500/D

28 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
28 0.5 7/0.30 0.8 1.8 22.0 36.0 0.0162 535 500/D
0.75 7/0.37 0.8 1.8 23.5 24.5 0.0142 650 500/D
1 7/0.40 0.8 1.8 24.0 18.1 0.0135 710 500/D
1.5 7/0.50 0.8 1.8 26.0 12.1 0.0115 915 500/D
2.5 7/0.67 0.8 1.8 30.0 7.41 0.0093 1350 500/D
4 7/0.85 1.0 2.0 37.0 4.61 0.0092 2110 500/D
6 7/1.04 1.0 2.2 41.5 3.08 0.0078 2885 500/D

29 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
29 0.5 7/0.30 0.8 1.8 22.0 36.0 0.0162 540 500/D
0.75 7/0.37 0.8 1.8 23.5 24.5 0.0142 660 500/D
1 7/0.40 0.8 1.8 24.0 18.1 0.0135 715 500/D
1.5 7/0.50 0.8 1.8 26.0 12.1 0.0115 930 500/D
2.5 7/0.67 0.8 1.8 30.0 7.41 0.0093 1370 500/D
4 7/0.85 1.0 2.0 37.0 4.61 0.0092 2145 500/D
6 7/1.04 1.0 2.2 41.5 3.08 0.0078 2940 500/D

30 Core CVV Control Cable

No. of core Nominal
cross-
sectional area
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance
(at20C)
Ohm/km
Minimum insulation resistance
(at70C)
Ohm/km
Cable
weight (Approx.) kg/km
Standard Length
m
30 0.5 7/0.30 0.8 1.8 22.0 36.0 0.0162 540 500/D
0.75 7/0.37 0.8 1.8 23.0 24.5 0.0142 665 500/D
1 7/0.40 0.8 1.8 24.0 18.1 0.0135 725 500/D
1.5 7/0.50 0.8 1.8 26.0 12.1 0.0115 940 500/D
2.5 7/0.67 0.8 1.8 30.0 7.41 0.0093 1395 500/D
4 7/0.85 1.0 2.0 37.0 4.61 0.0092 2180 500/D
6 7/1.04 1.0 2.2 41.5 3.08 0.0078 2990 500/D

The table of 0.6/1 KV CVV shown concentric stranded conductor only. If you want to have solid or flexible conductor type, please contact with our Sales Department.

Packing & Shipping
We provide you with the best product packaging design services, thereby allowing you to save more shipping charges.

FAQ

1. Q: Are you the factory or the trading company?
A: We are the factory.
2. Q: How long is your guarantee Period?
A: We usually offer 1 year guarantee for our general products.
3. Q: How can I get the samples?
A: We can make the sample order. And usually you will charge for it.
But the samples fee will be return to you when you make the bulk order.
4. Q: Where is your factory? How can we visit your factory?
A: Our factory located in Jiaozuo city, Henan Province and our office is in Zhengzhou city. You could reach here by train and by air. We can pick you up in the airport and the railway station.
5. Q: What is your MOQ?
A: It`s base on the cable type or size. Please contact Ms. Melon. She will offer you the details.

Factory

Established in 2004, Henan Hongda Cable Co., Ltd, is dedicated into manufacturing various types of electric power wire and cable. Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.
Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.

Our Service

1. Design wire and cable according to your real application
2. Optimized reel size for freight cost saving
3. Customized package to feature your brand
4. Short lead time to meet your urgent demand
5. Diversified delivery terms for your options
6. Quick response (24 hours on line)
7. Professional knowledge for clear answer to your any question
8. Comprehensive technical documents to support your tender bidding
9. One-year limited warranty for our wire and cable
10. Cable sample available
11. Specify the cable only according to the location
12. OEM is available
13. Abundant cables and wires for your option

Contact Us

Ms. Melon Liu
************************************************************************************************

Tel: +86 371 55367868 / 55367868 Fax: +86371 55367870
Mob. : +86 18339931106
Henan Hongda Cable Co., Ltd http://hongdacable
Changping Road 3,Zhandian NewDistrict,Wuzhi County,Jiaozuo,Henan Province, China
Office Add: Room2108,Yaxing Times Square,Zhengzhou,Henan,China. P.C. 450000
************************************************************************************************

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.