0.6/1kv 3X50+54.6+1X16mm2 XLPE Aluminum Aerial Cable

Quick Details
Product Details
Application
Aerial Bundled cable is widely used as transmission and distribution lines to replace overhead conductors In the areas such as downtown, factory and other populated and densely built areas. The rated voltage of this product is 600/1000V and below.
Product Description
1) Rated voltage: 600/1000V
2) Phase core conductor: aluminum
3) Sectional area: 10 – 400 mm2
4) Insulation: XLPE
5) Messenger conductor: 6201 aluminum alloy
6) Insulation: XLPE
7) Min. bending radius: 15 times cable radius
8) Max. conductor DC resistance at 20°c
|
Sectional area (mm2) |
10 |
16 |
25 |
35 |
50 |
70 |
95 |
|
Resistance (Ω/km) |
3.08 |
1.91 |
1.20 |
0.868 |
0.641 |
0.443 |
0.320 |
|
Sectional area (mm2) |
120 |
150 |
185 |
240 |
300 |
400 |
|
|
Resistance (Ω/km) |
0.253 |
0.206 |
0.164 |
0.125 |
0.100 |
0.0778 |
|
|
SPEC mm2 |
Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
|
Phase (compacted Al) |
Neutral (alloy) |
|||||
|
No./mm |
No./mm |
|||||
|
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE Or PVC or PE
|
1.2 |
12.5 |
110.1 |
|
1*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
14.9 |
163.9 |
|
|
1*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
17.5 |
229.0 |
|
|
1*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
20.1 |
300.0 |
|
|
1*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
23.6 |
423.2 |
|
|
1*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
27.6 |
585.4 |
|
|
2*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
14.2 |
175.8 |
|
|
2*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
16.7 |
258.4 |
|
|
2*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
19.7 |
361.2 |
|
|
2*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
22.5 |
472.1 |
|
|
2*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
26.1 |
658.3 |
|
|
2*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
30.5 |
908.2 |
|
|
3*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
16.3 |
241.5 |
|
|
3*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
19.1 |
353.6 |
|
|
3*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
22.5 |
493.5 |
|
|
3*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
25.7 |
644.1 |
|
|
3*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
29.7 |
895.2 |
|
|
3*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
34.6 |
1233.5 |
|
- Next: CAAI/CAAI-S ABC Cables with Aluminum Conductor XLPE Insulated Aerial Cable
- Previous: Steel Tape Armour STA Armoured Copper XLPE 12X2.5mm2 Control Cable
Contact us
Similar Or Related
-
AAC/AAAC Conductor Triplex Service Drop Cable XLPE Electric Cables
-
Outdoor Customized Aerial Bundled Cables Environmental Protection
-
3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant
-
Polyethylene Insulation 4 Core Aerial Bundled Cables 0.6kv / 1kv for Overhead Power Line
-
PVC Insulated Aerial Electrical Cable with 0.6/1 Kv AAC Conductors Triplex Service Drop Cable