Product Description

0.6/1kV 2 NX Y Cable XLPE INSULATED POWER CABLE

1. Brief Introduction
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.

Various of flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation. The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.

Our XLPE cable are produced according to our own technical specification which is equivalent to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers’ requirements.

XLPE cable can be applied in high temperature for a long time and has bigger current capacity. In the same environment conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross section by 1 or 2 grades. In this way, we not only can improve the qualities and properties of products, but also can reduce the production costs.
2. Scope

Chinese Type Qty. of Core Nominal Cross-Sectional
of Conductor(mm2)
YJV
YJV22
YJV32
YJV42
ZR-YJV*
ZR-YJY
ZR-YJV22
ZR-YJV23
ZR-YJV32
ZR-YJV33
ZR-YJV42
ZR-YJV43
YJLV
YJLV22
YJLV32
YJLV42
YJY
YJV23
YJV33
YJV43
ZR-YJLV
ZR-YJLV
ZR-YJLV22
ZR-YJLV23
ZR-YJLV32
ZR-YJLV33
ZR-YJLV42
ZR-YJLV43
YJLY
YJLV23
YJLV33
YJLV43
1 1.5~1000
2
3
4
5
1.5~400**
3+1
4+1
3+2
2.5~400

** Note: ZR-" flame-retardant cable covers three classes A, B, and C. They can be expressed as "ZRA-"or "ZRB-"or "ZRC-"respectively
For example: "ZRB-YJV", or "ZRA-YJV22".
Appendix
Multi-core cables with 3+1 cores, 4+1 cores and 3+2 cores should follow the following regulation:

Nominal
cross-section
(mm2)
Main Cores 2.5 4 6 10 16 25 35 50
Neutral Core 1.5 2.5 4 6 10 16 16 25
Nominal
cross-section
(mm2)
Main Cores 70 95 120 150 185 240 300 400
Neutral Core 35 50 70 70 95 120 150 185

3. Type and Description

Chinese Type Description
Cu Conductor Al Conductor
YJV
(YJY)
YJLV
(YJLY)
XLPE Insulated, PVC (PE) Sheathed Power Cable
YJV22
(YJV23)
YJLV22
(YJLV23)
XLPE Insulated, Steel Tape Armored, PVC(PE) Sheathed Power Cable
YJV32
(YJV33)
YJLV32
(YJLV33)
XLPE Insulated, Fine Steel Wire Armored, PVC(PE) Sheathed Power Cable
YJV42
(YJV43)
YJLV42
(YJLV43)
XLPE Insulated, Thick Steel Wire Armored, PVC(PE) Sheathed Power Cable
ZR-YJV
(ZR-YJY)
ZR-YJLV
(ZR-YJLY)
XLPE Insulated, PVC(PE) Sheathed Flame-retardant Power Cable
ZR-YJV22
(ZR-YJV23)
ZR-YJLV22
(ZR-YJLV23)
XLPE Insulated, Steel Tape Armored, PVC(PE) Sheathed Flame-retardant Power Cable
ZR-YJV32
(ZR-YJV33)
ZR-YJLV32
(ZR-YJLV33)
XLPE Insulated, Fine Steel Wire Armored, PVC(PE) Sheathed Flame-retardant Power Cable
ZR-YJV42
(ZR-YJV43)
ZR-YJLV42
(ZR-YJLV43)
XLPE Insulated, Thick Steel Wire Armored, PVC(PE) Sheathed Flame-retardant Power Cable

4. Main Technical Data

  1. DC Resistance:

Conductor resistance per km of finished cable at 20ºC should be no more than the following:

Nominal Cross-Section
(mm2)
1.5 2.5 4 6 10 16 25
Cu Conductor (Ω/km) 12.1 7.41 4.61 3.08 1.83 1.15 0.727
Al Conductor (Ω/km) 18.1 12.1 7.41 4.61 3.08 1.91 1.20
Nominal Cross-Section
(mm2)
35 50 70 95 120 150 185
Cu Conductor(Ω/km) 0.524 0.387 0.268 0.193 0.153 0.124 0.0991
Al Conductor (Ω/km) 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Nominal Cross-Section
(mm2)
240 300 400 500 630 800 1000
Cu Conductor (Ω/km) 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 0.0176
Al Conductor (Ω/km) 0.125 0.100 0.0778 0.0605 0.0469 0.0367 0.0291

B. Voltage Test
Each drum of finished products should withstand power frequency voltage 3.5kV for 5 minutes, the insulation is not breakdown.
5. Service Conditions and Parameters
The cable is applied to fixed installation for 0.6/1kV of power transportation and distribution line.
Max. rated temperature of conductor: nominal operating 90ºC
short circuit: (max. for 5 Sec.) 250ºC
Temperature of laid: in air 25ºC
underground 15ºC
For laying, single core, triangle laying for three cables.
Depth of laid: 100cm
Coefficient of thermal resistivity of soil 100ºC.cm/w
Cable can be laid without drop restriction, and environment temperature shall not be lower than 0ºC.
Single core, steel tape armored cable should be only applied to DC line.

If you want to know more about this kind of 2NX Y Cable, pls go forward to the followings:

Contact Detail: Sweety Tang

Zhengzhou Jinyuan Wire & Cable Co.,Ltd
Address: No.6 Building of Qifu Mingdu, Zhengzhou, China
Website: jytopcable
Tel:+86 371-55367868 Fax:+86 371-55367870
Mobile:+86-15238067380

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.

Similar Or Related