Product Description

1.Product Usage
The products applies to transmission and distribution of high voltagepower lines at rated voltage 6-35kV

2.Application Properties
The max rated temperature of conductor is 90ºC.When shortcircuited ,the max temperature of the conductor of cable is 250ºC.
The temperature of laying should not be lower than 0ºC,a heating be forhand is needed if the anbiebt temp of laying is lower than 0ºC.
The bend radius for laying :the one of single cire cable should not be shorter than fifteen times of outer diam:the one of the multi core should not be shorter than ten times of outer diam.
3.

Type  Description Application
Cu  Al 
YJV YJLV XLPE insulated and PVC sheathed power cable Can be laid in indoor,outdoor,tunnels,reinforced concrepte pipelines and loose soil .Cable can not bear outer mechanical force ,but can bear a certain tractional force.
YJV22 YJLV22 XLPE insulated ,steel tape armored and PVC shesthed power cable Laid underground ,cable can bear outer mechanical force ,but can be bear a large tractional force
YJV32 YJLV32 XLPE insulated ,thin steel wire armored and PVC sheathed power cable  Laid in indoor ,tunnels and mines .Cable can be bear outer mechanical force and fairly large tractional force .
YJV42 YJLV42 XLPE insulated ,thick steel wire armored and PVC sheathed power cable . Can be laid in vertical section ,indoor tunnels and mines .Cable can be bear outer mechanical force and bery large tractional force.

4.Range of production

core /area/rated voltage 0.6/1 1.8/3
single core 1 1.5-1000 10-1000
double core 2 1.5-240 10-240
three core 3 1.5-300 10-300
core3+2 2.5-300 10-300

Notes:core number,cross section depends on cable type,voltage.
 
5.

0.6/1kv XLPE/PVC POWER CABLE(unarmored) YJV,YJLV                            
                                           
sectional Area of Conductor(mm²) Thickness of insulation(mm) Non-metallic sheath unarmored cable
Thickness of sheath approx overall diameter approx cable weight(kg/km)
mm mm Cu Al
1c 2c 3c 4c 5c 1c 2c 3c 4c 5c 1c 2c 3c 4c 5c 1c 2c 3c 4c 5c
1.5 0.7 1.4 1.8 1.8 1.8 1.8 5.6 10 10.4 11.1 11.9 45 122 139 167 195 35 103 111 506 148
2.5 0.7 1.4 1.8 1.8 1.8 1.8 6 10.8 11.2 12.1 13 57 148 175 215 253 42 117 129 641 175
4 0.7 1.4 1.8 1.8 1.8 1.8 6.5 11.7 12.3 13.2 14.3 75 185 228 285 337 50 135 153 833 212
6 0.7 1.4 1.8 1.8 1.8 1.8 7 12.7 13.4 14.4 15.6 97 239 295 373 445 60 165 183 1086 258
10 0.7 1.4 1.8 1.8 1.8 1.8 8.1 15 15.8 17.2 18.7 143 346 445 568 681 80 220 256 1629 366
16 0.7 1.4 1.8 1.8 1.8 1.8 9.2 17.2 18.2 19.8 21.7 206 494 660 835 1008 106 292 358 2377 505
25 0.9 1.4 1.8 1.8 1.8 1.8 10.6 20 21.2 23.2 25.5 303 711 951 1217 1483 146 396 479 3457 696
35 0.9 1.4 1.8 1.8 1.8 1.8 11.8 22.4 23.8 26.1 28.7 403 919 1267 1598 1959 185 478 606 4528 858
50 1 1.4 1.8 1.8 1.9 2 13.2 25.2 26.8 29.7 32.9 554 1188 1675 2209 2733 241 558 731 6190 1160
70 1.1 1.4 1.9 1.9 2 2.1 15 22.2 25.7 30 36.2 755 1564 2260 2987 3735 317 683 939 8348 1533
95 1.1 1.5 2 2 2.1 2.3 16.9 25.2 29.1 34.2 40.3 1004 2069 3003 3977 4975 409 874 1210 11091 1987
120 1.2 1.5 2.1 2.1 2.3 2.4 18.5 28.2 32.4 37.2 44.7 1250 2592 3763 4983 6228 498 1082 1498 13880 2453
150 1.4 1.6 2.2 2.3 2.4 2.6 20.6 31 36.2 41.2 50.3 1558 3214 4700 6202 7777 619 1327 1869 17280 3059
185 1.6 1.6 2.3 2.4 2.6 2.8 22.7 36.8 40.4 46.2 58.6 1908 3978 5779 7655 9623 750 1650 2287 21355 3803
240 1.7 1.7 2.5 2.6 2.8 3 25.3 41.6 47.4 53.3 63.1 2450 5104 7456 9859 12326 947 2084 2926 27399 4776
300 1.8 1.8 2.7 2.8 3 3.2 27.9 46.4 50.1 59.4 68.2 3053 6328 9234 12260 15291 1163 2541 3554 33997 5824
400 2 1.9   3.1 3.3 3.6 31.6   57.2 68.4 83.1 4021   12224 16240 20305 1514   4651 36685 7683
500 2.2 2   3.3 3.3   35   74.2 82.2   5002   15136 20176   1869   5849 7554  
630 2.4 2.2         39.3         6290         2342        
800 2.6 2.3         44.8         7957         2943        
1000 2.8 2.4         49.9         9897         3629        

 

0.6/1kv XLPE/PVC POWER CABLE(unarmored) YJV,YJLV                              
                               
sectional Area of Conductor (mm²) Thickness of insulation (mm) Non-metallic sheath unarmored cable
thickness of sheath approx overall diameter cable weight
mm mm Cu Al
phase line zero line phase line zero line 3+1c 3+2c 4+1c 3+1c 3+2c 4+1c 3+1c 3+2c 4+1c 3+1c 3+2c 4+1c
2.5 1.5 0.7 0.7 1.8 1.8 1.8 11.9 12.6 12.8 206 229 253      
4 2.5 0.7 0.7 1.8 1.8 1.8 12.9 13.7 14 268 302 323 178 196 197
6 4 0.7 0.7 1.8 1.8 1.8 14.2 15.1 15.4 352 402 428 215 240 237
10 6 0.7 0.7 1.8 1.8 1.8 16.5 17.5 18.1 517 584 645 290 321 328
16 10 0.7 0.7 1.8 1.8 1.8 19.2 20.5 21.1 761 865 955 396 437 444
25 16 0.9 0.7 1.8 1.8 1.8 22.4 23.9 24.7 1110 1278 1406 538 605 606
35 16 0.9 0.7 1.8 1.8 1.8 24.6 25.9 27.3 1402 1558 1805 647 709 731
50 25 1 0.9 1.8 1.9 1.9 28 29.9 31.3 1943 2243 2531 842 984 975
70 35 1.1 0.9 1.9 2 2.1 29.5 33.2 34.4 2645 3038 3412 1101 1273 1234
95 50 1.1 1 2.1 2.2 2.2 33.2 37.8 38.7 3554 4105 4551 1443 1679 1579
120 70 1.2 1.1 2.2 2.3 2.4 36.3 41.6 43.6 4504 5265 5791 1793 2112 1993
150 70 1.4 1.1 2.3 2.4 2.5 39.7 45.9 47.9 5425 6200 7018 2147 2480 2380
185 95 1.6 1.1 2.5 2.6 2.7 45.4 51.4 53.3 6781 7792 8720 2683 3095 2946
240 120 1.7 1.2 2.7 2.8 2.9 53 58.6 60.1 8708 9960 11172 3412 3907 3701
300 150 1.8 1.4 2.9 3 3.1 58.3 65.4 62.9 10818 12394 13827 4192 4823 4480
400 185 2 1.6 3.1 3.3 3.4 67.5 74. 2 67.8 14163 16132 18093 5423 6225 5725