Product Description
triplex overhead aluminum and underground wire for AAC/ AAAC/ACSR cable
Construction of triplex cable
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together(LH lay) or parallel if so specified. Black neutrals may be specified if desired.
Standards
ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Federal Specification JC-30B NEC
Specification :
Code Name |
Phase Conductor | Neutral | Single Phase Conductor (in) |
Outside Diameter (in) |
Weight Per 1000ft (lbs) |
Ampacity | |||||
Size AWG |
Strand | Insulation Thickness (mls) |
Size AWG |
Strand | Insulation thickness(mls) | Direct Burial |
In Duct | ||||
Erksine | 6 | 7/w | 60 | 6 | 7/w | 60 | .299 | .646 | 143 | 95 | 70 |
Vassar | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .754 | 203 | 125 | 90 |
Stephens | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .842 | 264 | 165 | 120 |
Ramapo | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .874 | 294 | 165 | 120 |
Brenau | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.064 | 408 | 215 | 160 |
Bergen | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.133 | 465 | 215 | 160 |
Converse | 2/0 | 19/w | 80 | 1 | 19/w | 80 | .566 | 1.174 | 502 | 245 | 180 |
Hunter | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.228 | 560 | 245 | 180 |
Hollins | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.276 | 606 | 280 | 205 |
Rockland | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.336 | 678 | 280 | 205 |
Sweetbriar | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.389 | 739 | 315 | 240 |
Monmouth | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.457 | 828 | 315 | 240 |
Pratt | 250 | 37/w | 95 | 3/0 | 19/w | 80 | .748 | 1.538 | 893 | 345 | 265 |
Wesleyan | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.736 | 1166 | 415 | 320 |
Holyoke | 500 | 37/w | 95 | 300 | 37/w | 95 | .979 | 2.008 | 1607 | 495 | 395 |
Rider | 500 | 37/w | 95 | 350 | 37/w | 95 | .979 | 2.035 | 1663 | 495 | 395 |
Fairfield | 750 | 61/w | 110 | 500 | 37/w | 95 | 1.188 | 2.086 | 2304 | 615 | 525 |